Front-end design for non-invasive electrical resistance tomography for liquid column

This paper explains the front-end design for non-invasive electrical resistance tomography. The electrical resistance tomography system presented in this paper uses high frequency potential. In this design, the phase-shift demodulation (PSD) approach was eliminated and replaced by a peak detector ci...

Full description

Bibliographic Details
Main Authors: Yasmin, Abdul Wahab, Ruzairi, Abdul Rahim, Mohd Anwar, Zawawi, Mohd Hafiz Fazalul, Rahiman, Ling, Leow Pei, Juliza, Jamaluddin, Goh, Helen, Suzanna, Ridzuan Aw, Herlina, Abdul Rahim
Format: Article
Language:English
English
Published: Universiti Teknikal Malaysia Melaka (UTeM) 2018
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/19487/
http://umpir.ump.edu.my/id/eprint/19487/1/Front-End%20Design%20For%20Non-Invasive%20Electrical%20Resistance%20Tomography%20For%20Liquid%20Column.pdf
http://umpir.ump.edu.my/id/eprint/19487/7/Front-End%20Design%20For%20Non-Invasive%20Electrical%20Resistance%20Tomography%20For%20Liquid%20Column%201.pdf
_version_ 1848820890891976704
author Yasmin, Abdul Wahab
Ruzairi, Abdul Rahim
Mohd Anwar, Zawawi
Mohd Hafiz Fazalul, Rahiman
Ling, Leow Pei
Juliza, Jamaluddin
Goh, Helen
Suzanna, Ridzuan Aw
Herlina, Abdul Rahim
author_facet Yasmin, Abdul Wahab
Ruzairi, Abdul Rahim
Mohd Anwar, Zawawi
Mohd Hafiz Fazalul, Rahiman
Ling, Leow Pei
Juliza, Jamaluddin
Goh, Helen
Suzanna, Ridzuan Aw
Herlina, Abdul Rahim
author_sort Yasmin, Abdul Wahab
building UMP Institutional Repository
collection Online Access
description This paper explains the front-end design for non-invasive electrical resistance tomography. The electrical resistance tomography system presented in this paper uses high frequency potential. In this design, the phase-shift demodulation (PSD) approach was eliminated and replaced by a peak detector circuit. The switching between transmitter/receiver and the transmitting channel was controlled by analogue switch, MAX319 and demultiplexer, DG406, respectively. A microcontroller was applied as the data acquisition which eliminates the needs of a data acquisition system. Sensor readings of each receiver from each transmitter groups were tested experimentally, compared and analysed with simulation results. These experimental readings were compared with the sensors reading simulated from COMSOL Multiphysics software. As a result, the current values between 0-1mA from experiments was similar with the simulation results for all groups of transmitters. Thus, it can be concluded that the front-end design can be applied for the non-invasive ERT when high frequency is considered.
first_indexed 2025-11-15T02:16:39Z
format Article
id ump-19487
institution Universiti Malaysia Pahang
institution_category Local University
language English
English
last_indexed 2025-11-15T02:16:39Z
publishDate 2018
publisher Universiti Teknikal Malaysia Melaka (UTeM)
recordtype eprints
repository_type Digital Repository
spelling ump-194872018-07-23T07:23:20Z http://umpir.ump.edu.my/id/eprint/19487/ Front-end design for non-invasive electrical resistance tomography for liquid column Yasmin, Abdul Wahab Ruzairi, Abdul Rahim Mohd Anwar, Zawawi Mohd Hafiz Fazalul, Rahiman Ling, Leow Pei Juliza, Jamaluddin Goh, Helen Suzanna, Ridzuan Aw Herlina, Abdul Rahim TK Electrical engineering. Electronics Nuclear engineering This paper explains the front-end design for non-invasive electrical resistance tomography. The electrical resistance tomography system presented in this paper uses high frequency potential. In this design, the phase-shift demodulation (PSD) approach was eliminated and replaced by a peak detector circuit. The switching between transmitter/receiver and the transmitting channel was controlled by analogue switch, MAX319 and demultiplexer, DG406, respectively. A microcontroller was applied as the data acquisition which eliminates the needs of a data acquisition system. Sensor readings of each receiver from each transmitter groups were tested experimentally, compared and analysed with simulation results. These experimental readings were compared with the sensors reading simulated from COMSOL Multiphysics software. As a result, the current values between 0-1mA from experiments was similar with the simulation results for all groups of transmitters. Thus, it can be concluded that the front-end design can be applied for the non-invasive ERT when high frequency is considered. Universiti Teknikal Malaysia Melaka (UTeM) 2018 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/19487/1/Front-End%20Design%20For%20Non-Invasive%20Electrical%20Resistance%20Tomography%20For%20Liquid%20Column.pdf pdf en http://umpir.ump.edu.my/id/eprint/19487/7/Front-End%20Design%20For%20Non-Invasive%20Electrical%20Resistance%20Tomography%20For%20Liquid%20Column%201.pdf Yasmin, Abdul Wahab and Ruzairi, Abdul Rahim and Mohd Anwar, Zawawi and Mohd Hafiz Fazalul, Rahiman and Ling, Leow Pei and Juliza, Jamaluddin and Goh, Helen and Suzanna, Ridzuan Aw and Herlina, Abdul Rahim (2018) Front-end design for non-invasive electrical resistance tomography for liquid column. Journal of Telecommunication, Electronic and Computer Engineering (JTEC), 10 (1-2). pp. 55-60. ISSN 2180-1843. (Published) http://journal.utem.edu.my/index.php/jtec/article/view/3321/2390
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Yasmin, Abdul Wahab
Ruzairi, Abdul Rahim
Mohd Anwar, Zawawi
Mohd Hafiz Fazalul, Rahiman
Ling, Leow Pei
Juliza, Jamaluddin
Goh, Helen
Suzanna, Ridzuan Aw
Herlina, Abdul Rahim
Front-end design for non-invasive electrical resistance tomography for liquid column
title Front-end design for non-invasive electrical resistance tomography for liquid column
title_full Front-end design for non-invasive electrical resistance tomography for liquid column
title_fullStr Front-end design for non-invasive electrical resistance tomography for liquid column
title_full_unstemmed Front-end design for non-invasive electrical resistance tomography for liquid column
title_short Front-end design for non-invasive electrical resistance tomography for liquid column
title_sort front-end design for non-invasive electrical resistance tomography for liquid column
topic TK Electrical engineering. Electronics Nuclear engineering
url http://umpir.ump.edu.my/id/eprint/19487/
http://umpir.ump.edu.my/id/eprint/19487/
http://umpir.ump.edu.my/id/eprint/19487/1/Front-End%20Design%20For%20Non-Invasive%20Electrical%20Resistance%20Tomography%20For%20Liquid%20Column.pdf
http://umpir.ump.edu.my/id/eprint/19487/7/Front-End%20Design%20For%20Non-Invasive%20Electrical%20Resistance%20Tomography%20For%20Liquid%20Column%201.pdf