Spatial Variation of Water Quality Parameters in Gebeng Industrial Area, Pahang, Malaysia

The study was conducted to examine the physico-chemical parameters of surface water quality in the Gebeng Industrial area, Pahang, Malaysia. Water samples were collected monthly from the selected 10 sampling site in the study area. The selected parameters were analyzed based on in-situ and ex-situ a...

Full description

Bibliographic Details
Main Authors: Islam, Mir Sujaul, Hossain, Mohamed Amjed, Sobahan, Md Abdus, Zularisam, A. W., Edriyana, Abd Aziz
Format: Conference or Workshop Item
Language:English
Published: IACSIT Press, Singapore 2012
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/11995/
http://umpir.ump.edu.my/id/eprint/11995/1/Hong%20Kong_Spatial%20variation%20of%20water%20quality%20parameters%20in%20Gebeng%20industrial%20area%2C%20Pahang%2C%20Malaysia.pdf
_version_ 1848819124502790144
author Islam, Mir Sujaul
Hossain, Mohamed Amjed
Sobahan, Md Abdus
Zularisam, A. W.
Edriyana, Abd Aziz
author_facet Islam, Mir Sujaul
Hossain, Mohamed Amjed
Sobahan, Md Abdus
Zularisam, A. W.
Edriyana, Abd Aziz
author_sort Islam, Mir Sujaul
building UMP Institutional Repository
collection Online Access
description The study was conducted to examine the physico-chemical parameters of surface water quality in the Gebeng Industrial area, Pahang, Malaysia. Water samples were collected monthly from the selected 10 sampling site in the study area. The selected parameters were analyzed based on in-situ and ex-situ analysis according to standard methods. The statistical software was used for data analyses. It was observed that, the non-point source pollutants were associated with runoff from construction sites of newly developed industrial areas and the point source contributing the major pollutants especially from industrial wastes. Low levels of dissolved oxygen (DO) and higher levels of chemical oxygen demand (COD), biochemical oxygen demand (BOD), total suspended solids (TSS), ammoniacal nitrogen and selected heavy metals made the water pollution. According to Interim National Water Quality Standard (INWQS), the major part of the river specially the mid-region was categorized as class V (very highly polluted) while some part was found to be in class IV (highly polluted) and rest of class III (polluted) as well. Based on Malaysian Water Quality Index (WQI), the most stations except lower and uppermost were in class IV, and highly polluted.
first_indexed 2025-11-15T01:48:34Z
format Conference or Workshop Item
id ump-11995
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T01:48:34Z
publishDate 2012
publisher IACSIT Press, Singapore
recordtype eprints
repository_type Digital Repository
spelling ump-119952018-09-28T03:46:11Z http://umpir.ump.edu.my/id/eprint/11995/ Spatial Variation of Water Quality Parameters in Gebeng Industrial Area, Pahang, Malaysia Islam, Mir Sujaul Hossain, Mohamed Amjed Sobahan, Md Abdus Zularisam, A. W. Edriyana, Abd Aziz TA Engineering (General). Civil engineering (General) TD Environmental technology. Sanitary engineering The study was conducted to examine the physico-chemical parameters of surface water quality in the Gebeng Industrial area, Pahang, Malaysia. Water samples were collected monthly from the selected 10 sampling site in the study area. The selected parameters were analyzed based on in-situ and ex-situ analysis according to standard methods. The statistical software was used for data analyses. It was observed that, the non-point source pollutants were associated with runoff from construction sites of newly developed industrial areas and the point source contributing the major pollutants especially from industrial wastes. Low levels of dissolved oxygen (DO) and higher levels of chemical oxygen demand (COD), biochemical oxygen demand (BOD), total suspended solids (TSS), ammoniacal nitrogen and selected heavy metals made the water pollution. According to Interim National Water Quality Standard (INWQS), the major part of the river specially the mid-region was categorized as class V (very highly polluted) while some part was found to be in class IV (highly polluted) and rest of class III (polluted) as well. Based on Malaysian Water Quality Index (WQI), the most stations except lower and uppermost were in class IV, and highly polluted. IACSIT Press, Singapore 2012 Conference or Workshop Item NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/11995/1/Hong%20Kong_Spatial%20variation%20of%20water%20quality%20parameters%20in%20Gebeng%20industrial%20area%2C%20Pahang%2C%20Malaysia.pdf Islam, Mir Sujaul and Hossain, Mohamed Amjed and Sobahan, Md Abdus and Zularisam, A. W. and Edriyana, Abd Aziz (2012) Spatial Variation of Water Quality Parameters in Gebeng Industrial Area, Pahang, Malaysia. In: International Proceedings of Chemical, Biological and Environmental Engineering (IPCBEE) , 29-30 December 2012 , Hong Kong. pp. 6-11., 49. ISSN 2010-4618 ISBN 2010-4618 (Published) http://www.ipcbee.com/vol49/002-ICECB2012-B30001.pdf
spellingShingle TA Engineering (General). Civil engineering (General)
TD Environmental technology. Sanitary engineering
Islam, Mir Sujaul
Hossain, Mohamed Amjed
Sobahan, Md Abdus
Zularisam, A. W.
Edriyana, Abd Aziz
Spatial Variation of Water Quality Parameters in Gebeng Industrial Area, Pahang, Malaysia
title Spatial Variation of Water Quality Parameters in Gebeng Industrial Area, Pahang, Malaysia
title_full Spatial Variation of Water Quality Parameters in Gebeng Industrial Area, Pahang, Malaysia
title_fullStr Spatial Variation of Water Quality Parameters in Gebeng Industrial Area, Pahang, Malaysia
title_full_unstemmed Spatial Variation of Water Quality Parameters in Gebeng Industrial Area, Pahang, Malaysia
title_short Spatial Variation of Water Quality Parameters in Gebeng Industrial Area, Pahang, Malaysia
title_sort spatial variation of water quality parameters in gebeng industrial area, pahang, malaysia
topic TA Engineering (General). Civil engineering (General)
TD Environmental technology. Sanitary engineering
url http://umpir.ump.edu.my/id/eprint/11995/
http://umpir.ump.edu.my/id/eprint/11995/
http://umpir.ump.edu.my/id/eprint/11995/1/Hong%20Kong_Spatial%20variation%20of%20water%20quality%20parameters%20in%20Gebeng%20industrial%20area%2C%20Pahang%2C%20Malaysia.pdf