The effect of stent void area on hemodynamics in cerebral aneurysm

The purpose of this study is to develop modeling methodologies to understand how different stent void area alter the aneurysmal flow. Four difference stents design with difference void area were created with suitable geometry for Computational Fluid Dynamics (CFD) analysis. The velocity profile and...

Full description

Bibliographic Details
Main Author: Suriani, Abd Rahman
Format: Undergraduates Project Papers
Language:English
Published: 2009
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/1116/
http://umpir.ump.edu.my/id/eprint/1116/1/Suriani_Abd_Rahman.pdf
_version_ 1848816785781948416
author Suriani, Abd Rahman
author_facet Suriani, Abd Rahman
author_sort Suriani, Abd Rahman
building UMP Institutional Repository
collection Online Access
description The purpose of this study is to develop modeling methodologies to understand how different stent void area alter the aneurysmal flow. Four difference stents design with difference void area were created with suitable geometry for Computational Fluid Dynamics (CFD) analysis. The velocity profile and pressure distribution after installing the device had been identified from the selected stent. These four types of design will be referred as stent type I, II, III, and IV and these stent was tested in an aneurysm model. The simulation of the model was studied under incompressible, Newtonian, viscous, non pulsatile condition. In this study, we need to determine the correlation between stent porous area and blood flow and to determine the flow behavior in stented aneurysm. We found the stent design affected a cerebral aneurysm hemodynamic. The different of stent structural pattern produces the different results of flow field around the stented aneurysm. The minimum velocity had improved after stents insertion and the type IV with less void area results most optimized. Other than that, the peak pressure will also decrease after the stent implantation. As expected, the lowest peak pressure results from stent type IV. The result shows that the stent with the lowest void area gives the best performance.
first_indexed 2025-11-15T01:11:24Z
format Undergraduates Project Papers
id ump-1116
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T01:11:24Z
publishDate 2009
recordtype eprints
repository_type Digital Repository
spelling ump-11162021-06-21T04:29:05Z http://umpir.ump.edu.my/id/eprint/1116/ The effect of stent void area on hemodynamics in cerebral aneurysm Suriani, Abd Rahman TA Engineering (General). Civil engineering (General) The purpose of this study is to develop modeling methodologies to understand how different stent void area alter the aneurysmal flow. Four difference stents design with difference void area were created with suitable geometry for Computational Fluid Dynamics (CFD) analysis. The velocity profile and pressure distribution after installing the device had been identified from the selected stent. These four types of design will be referred as stent type I, II, III, and IV and these stent was tested in an aneurysm model. The simulation of the model was studied under incompressible, Newtonian, viscous, non pulsatile condition. In this study, we need to determine the correlation between stent porous area and blood flow and to determine the flow behavior in stented aneurysm. We found the stent design affected a cerebral aneurysm hemodynamic. The different of stent structural pattern produces the different results of flow field around the stented aneurysm. The minimum velocity had improved after stents insertion and the type IV with less void area results most optimized. Other than that, the peak pressure will also decrease after the stent implantation. As expected, the lowest peak pressure results from stent type IV. The result shows that the stent with the lowest void area gives the best performance. 2009-11 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/1116/1/Suriani_Abd_Rahman.pdf Suriani, Abd Rahman (2009) The effect of stent void area on hemodynamics in cerebral aneurysm. Faculty of Mechanical Engineering, Universiti Malaysia Pahang.
spellingShingle TA Engineering (General). Civil engineering (General)
Suriani, Abd Rahman
The effect of stent void area on hemodynamics in cerebral aneurysm
title The effect of stent void area on hemodynamics in cerebral aneurysm
title_full The effect of stent void area on hemodynamics in cerebral aneurysm
title_fullStr The effect of stent void area on hemodynamics in cerebral aneurysm
title_full_unstemmed The effect of stent void area on hemodynamics in cerebral aneurysm
title_short The effect of stent void area on hemodynamics in cerebral aneurysm
title_sort effect of stent void area on hemodynamics in cerebral aneurysm
topic TA Engineering (General). Civil engineering (General)
url http://umpir.ump.edu.my/id/eprint/1116/
http://umpir.ump.edu.my/id/eprint/1116/1/Suriani_Abd_Rahman.pdf