Design and optimization of mems accelerometer sensor for lower limb exoskeleton application / Muhammad Fareq Ibrahim

Currently a lot of studies have added their focuses into several backgrounds that are known as multi-discipline studies. One of the study is on lower limb exoskeleton which are the combination of electrical, mechanical and biomedical field. Lower limb exoskeleton study evolve on potential of helping...

Full description

Bibliographic Details
Main Author: Muhammad Fareq , Ibrahim
Format: Thesis
Published: 2018
Subjects:
Online Access:http://studentsrepo.um.edu.my/8501/
http://studentsrepo.um.edu.my/8501/7/fareq.pdf
_version_ 1848773675215486976
author Muhammad Fareq , Ibrahim
author_facet Muhammad Fareq , Ibrahim
author_sort Muhammad Fareq , Ibrahim
building UM Research Repository
collection Online Access
description Currently a lot of studies have added their focuses into several backgrounds that are known as multi-discipline studies. One of the study is on lower limb exoskeleton which are the combination of electrical, mechanical and biomedical field. Lower limb exoskeleton study evolve on potential of helping disable people to walk again. Lower limb exoskeleton consists of multi components and one of it is the MEMS accelerometer. MEMS accelerometer are used to give an accurate angle at the joint of lower limb exoskeleton because the exoskeleton must be designed to be as similar as possible with the real human’s leg. For this reason, an existing study on design of dual-axis MEMS accelerometer have been selected and simulated by using COMSOL Multiphysics. This design will be studied to obtain the optimal results on maximum stress and displacement sensitivity on X-axis and Y-axis. Three parameters have been modified into ±5%, ±10%, ±15%, ±20%, and ±25% to see their effect which are the lengths and widths of the beam and thickness of device. Taguchi method has been used for the optimization to get the optimal results. From the simulation results and analysis, this study was able to get 26.6419% and 60% of improvement of maximum stress and displacement sensitivity on X-axis and 31.8163% and 61.1556% of improvement of maximum stress and displacement sensitivity on Y-axis.
first_indexed 2025-11-14T13:46:10Z
format Thesis
id um-8501
institution University Malaya
institution_category Local University
last_indexed 2025-11-14T13:46:10Z
publishDate 2018
recordtype eprints
repository_type Digital Repository
spelling um-85012021-04-11T17:09:09Z Design and optimization of mems accelerometer sensor for lower limb exoskeleton application / Muhammad Fareq Ibrahim Muhammad Fareq , Ibrahim T Technology (General) TK Electrical engineering. Electronics Nuclear engineering Currently a lot of studies have added their focuses into several backgrounds that are known as multi-discipline studies. One of the study is on lower limb exoskeleton which are the combination of electrical, mechanical and biomedical field. Lower limb exoskeleton study evolve on potential of helping disable people to walk again. Lower limb exoskeleton consists of multi components and one of it is the MEMS accelerometer. MEMS accelerometer are used to give an accurate angle at the joint of lower limb exoskeleton because the exoskeleton must be designed to be as similar as possible with the real human’s leg. For this reason, an existing study on design of dual-axis MEMS accelerometer have been selected and simulated by using COMSOL Multiphysics. This design will be studied to obtain the optimal results on maximum stress and displacement sensitivity on X-axis and Y-axis. Three parameters have been modified into ±5%, ±10%, ±15%, ±20%, and ±25% to see their effect which are the lengths and widths of the beam and thickness of device. Taguchi method has been used for the optimization to get the optimal results. From the simulation results and analysis, this study was able to get 26.6419% and 60% of improvement of maximum stress and displacement sensitivity on X-axis and 31.8163% and 61.1556% of improvement of maximum stress and displacement sensitivity on Y-axis. 2018-01 Thesis NonPeerReviewed application/pdf http://studentsrepo.um.edu.my/8501/7/fareq.pdf Muhammad Fareq , Ibrahim (2018) Design and optimization of mems accelerometer sensor for lower limb exoskeleton application / Muhammad Fareq Ibrahim. Masters thesis, University of Malaya. http://studentsrepo.um.edu.my/8501/
spellingShingle T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
Muhammad Fareq , Ibrahim
Design and optimization of mems accelerometer sensor for lower limb exoskeleton application / Muhammad Fareq Ibrahim
title Design and optimization of mems accelerometer sensor for lower limb exoskeleton application / Muhammad Fareq Ibrahim
title_full Design and optimization of mems accelerometer sensor for lower limb exoskeleton application / Muhammad Fareq Ibrahim
title_fullStr Design and optimization of mems accelerometer sensor for lower limb exoskeleton application / Muhammad Fareq Ibrahim
title_full_unstemmed Design and optimization of mems accelerometer sensor for lower limb exoskeleton application / Muhammad Fareq Ibrahim
title_short Design and optimization of mems accelerometer sensor for lower limb exoskeleton application / Muhammad Fareq Ibrahim
title_sort design and optimization of mems accelerometer sensor for lower limb exoskeleton application / muhammad fareq ibrahim
topic T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
url http://studentsrepo.um.edu.my/8501/
http://studentsrepo.um.edu.my/8501/7/fareq.pdf