Low impedance restricted earth fault algorithms in numerical relays / Babak Nim Taj

Low impedance restricted earth fault protection is one of the protection function to protect the transformer winding with earthed neutral point. The purpose of this study is to investigate low impedance restricted earth fault algorithm in numerical relays. Five restricted earth fault numerical algor...

Full description

Bibliographic Details
Main Author: Babak, Nim Taj
Format: Thesis
Published: 2010
Subjects:
Online Access:http://www.pendeta.um.edu.my/uhtbin/cgisirsi/x/0/0/57/5/3?searchdata1=853856{CKEY}&searchfield1=GENERAL^SUBJECT^GENERAL^^&user_id=WEBSERVER
http://studentsrepo.um.edu.my/3610/1/New_folder_(4).zip
http://studentsrepo.um.edu.my/3610/2/TITLE_PAGE%2C_ABSTRACT%2C_CONTENT.pdf
http://studentsrepo.um.edu.my/3610/3/chapter_1.pdf
http://studentsrepo.um.edu.my/3610/4/chapter_2.pdf
http://studentsrepo.um.edu.my/3610/5/chapter_3.pdf
http://studentsrepo.um.edu.my/3610/6/chapter_4.pdf
http://studentsrepo.um.edu.my/3610/7/chapter_5.pdf
http://studentsrepo.um.edu.my/3610/8/references.pdf
_version_ 1848772453815287808
author Babak, Nim Taj
author_facet Babak, Nim Taj
author_sort Babak, Nim Taj
building UM Research Repository
collection Online Access
description Low impedance restricted earth fault protection is one of the protection function to protect the transformer winding with earthed neutral point. The purpose of this study is to investigate low impedance restricted earth fault algorithm in numerical relays. Five restricted earth fault numerical algorithms from ABB, AREVA T&D, SIEMENS, SCHNEIDER ELECTRIC and GENERAL ELECTRIC are employed for restricted earth fault algorithms assessment.This dissertation is to find out advantages and disadvantages of selected algorithms. Moreover, this dissertation is to compare each algorithm with the other algorithms. Also, magnetizing inrush current, over excitation and CT saturation impression on restricted earth fault operation is presented. After the algorithms assessment, two of them (Siemens and General Electric) are selected for simulation (MATLAB SIMULINK). These algorithms are compared and advantages and disadvantages of them are presented.
first_indexed 2025-11-14T13:26:46Z
format Thesis
id um-3610
institution University Malaya
institution_category Local University
last_indexed 2025-11-14T13:26:46Z
publishDate 2010
recordtype eprints
repository_type Digital Repository
spelling um-36102019-05-08T23:00:15Z Low impedance restricted earth fault algorithms in numerical relays / Babak Nim Taj Babak, Nim Taj TK Electrical engineering. Electronics Nuclear engineering Low impedance restricted earth fault protection is one of the protection function to protect the transformer winding with earthed neutral point. The purpose of this study is to investigate low impedance restricted earth fault algorithm in numerical relays. Five restricted earth fault numerical algorithms from ABB, AREVA T&D, SIEMENS, SCHNEIDER ELECTRIC and GENERAL ELECTRIC are employed for restricted earth fault algorithms assessment.This dissertation is to find out advantages and disadvantages of selected algorithms. Moreover, this dissertation is to compare each algorithm with the other algorithms. Also, magnetizing inrush current, over excitation and CT saturation impression on restricted earth fault operation is presented. After the algorithms assessment, two of them (Siemens and General Electric) are selected for simulation (MATLAB SIMULINK). These algorithms are compared and advantages and disadvantages of them are presented. 2010-08-10 Thesis NonPeerReviewed application/zip http://studentsrepo.um.edu.my/3610/1/New_folder_(4).zip application/pdf http://studentsrepo.um.edu.my/3610/2/TITLE_PAGE%2C_ABSTRACT%2C_CONTENT.pdf application/pdf http://studentsrepo.um.edu.my/3610/3/chapter_1.pdf application/pdf http://studentsrepo.um.edu.my/3610/4/chapter_2.pdf application/pdf http://studentsrepo.um.edu.my/3610/5/chapter_3.pdf application/pdf http://studentsrepo.um.edu.my/3610/6/chapter_4.pdf application/pdf http://studentsrepo.um.edu.my/3610/7/chapter_5.pdf application/pdf http://studentsrepo.um.edu.my/3610/8/references.pdf http://www.pendeta.um.edu.my/uhtbin/cgisirsi/x/0/0/57/5/3?searchdata1=853856{CKEY}&searchfield1=GENERAL^SUBJECT^GENERAL^^&user_id=WEBSERVER Babak, Nim Taj (2010) Low impedance restricted earth fault algorithms in numerical relays / Babak Nim Taj. Other thesis, University of Malaya. http://studentsrepo.um.edu.my/3610/
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Babak, Nim Taj
Low impedance restricted earth fault algorithms in numerical relays / Babak Nim Taj
title Low impedance restricted earth fault algorithms in numerical relays / Babak Nim Taj
title_full Low impedance restricted earth fault algorithms in numerical relays / Babak Nim Taj
title_fullStr Low impedance restricted earth fault algorithms in numerical relays / Babak Nim Taj
title_full_unstemmed Low impedance restricted earth fault algorithms in numerical relays / Babak Nim Taj
title_short Low impedance restricted earth fault algorithms in numerical relays / Babak Nim Taj
title_sort low impedance restricted earth fault algorithms in numerical relays / babak nim taj
topic TK Electrical engineering. Electronics Nuclear engineering
url http://www.pendeta.um.edu.my/uhtbin/cgisirsi/x/0/0/57/5/3?searchdata1=853856{CKEY}&searchfield1=GENERAL^SUBJECT^GENERAL^^&user_id=WEBSERVER
http://www.pendeta.um.edu.my/uhtbin/cgisirsi/x/0/0/57/5/3?searchdata1=853856{CKEY}&searchfield1=GENERAL^SUBJECT^GENERAL^^&user_id=WEBSERVER
http://studentsrepo.um.edu.my/3610/1/New_folder_(4).zip
http://studentsrepo.um.edu.my/3610/2/TITLE_PAGE%2C_ABSTRACT%2C_CONTENT.pdf
http://studentsrepo.um.edu.my/3610/3/chapter_1.pdf
http://studentsrepo.um.edu.my/3610/4/chapter_2.pdf
http://studentsrepo.um.edu.my/3610/5/chapter_3.pdf
http://studentsrepo.um.edu.my/3610/6/chapter_4.pdf
http://studentsrepo.um.edu.my/3610/7/chapter_5.pdf
http://studentsrepo.um.edu.my/3610/8/references.pdf