Design and preliminary finite element analysis of planar rotary spring for BioApps RoMicP® ankle-foot prosthesis / Aufar Syehan

Series elastic actuator (SEA) is an excellent option for a powered ankle-foot prosthesis. However, to achieve the best actuator performance, the optimum stiffness of the planar rotary spring should be defined by using a dynamic model. The main objective of this study is to develop a planar rotary sp...

Full description

Bibliographic Details
Main Author: Aufar, Syehan
Format: Thesis
Published: 2022
Subjects:
Online Access:http://studentsrepo.um.edu.my/13627/
http://studentsrepo.um.edu.my/13627/1/Aufar_Syehan.jpg
http://studentsrepo.um.edu.my/13627/8/aufar.pdf
_version_ 1848774867415990272
author Aufar, Syehan
author_facet Aufar, Syehan
author_sort Aufar, Syehan
building UM Research Repository
collection Online Access
description Series elastic actuator (SEA) is an excellent option for a powered ankle-foot prosthesis. However, to achieve the best actuator performance, the optimum stiffness of the planar rotary spring should be defined by using a dynamic model. The main objective of this study is to develop a planar rotary spring design with an optimum stiffness. Maraging 300 Alloy Steel or commercially known as Vascomax-300 was selected as the material of the planar rotary spring for the BioApps RoMicP®️ ankle-foot prosthesis. Furthermore, Archimedean spiral was chosen as the topological shape of the spring. The spring model was developed in an iterative method, where the width and thickness of the spring’ arm were the parameters to be modified until the spring model reached the optimum stiffness value. The definition of an optimum torsional spring stiffness is when the power required by the motor is minimum. Following the completion of the design advancement the reliability of the preliminary spring design was examined by using the Finite Element Method (FEM). Based on the simulation, the planar rotary spring model was able to withstand a maximum torque of 102.793 Nm. The spring rotation was 0.163 rad, corresponding to a torsional stiffness between 620 and 630 Nm/rad.
first_indexed 2025-11-14T14:05:07Z
format Thesis
id um-13627
institution University Malaya
institution_category Local University
last_indexed 2025-11-14T14:05:07Z
publishDate 2022
recordtype eprints
repository_type Digital Repository
spelling um-136272022-08-25T18:19:19Z Design and preliminary finite element analysis of planar rotary spring for BioApps RoMicP® ankle-foot prosthesis / Aufar Syehan Aufar, Syehan R Medicine (General) T Technology (General) Series elastic actuator (SEA) is an excellent option for a powered ankle-foot prosthesis. However, to achieve the best actuator performance, the optimum stiffness of the planar rotary spring should be defined by using a dynamic model. The main objective of this study is to develop a planar rotary spring design with an optimum stiffness. Maraging 300 Alloy Steel or commercially known as Vascomax-300 was selected as the material of the planar rotary spring for the BioApps RoMicP®️ ankle-foot prosthesis. Furthermore, Archimedean spiral was chosen as the topological shape of the spring. The spring model was developed in an iterative method, where the width and thickness of the spring’ arm were the parameters to be modified until the spring model reached the optimum stiffness value. The definition of an optimum torsional spring stiffness is when the power required by the motor is minimum. Following the completion of the design advancement the reliability of the preliminary spring design was examined by using the Finite Element Method (FEM). Based on the simulation, the planar rotary spring model was able to withstand a maximum torque of 102.793 Nm. The spring rotation was 0.163 rad, corresponding to a torsional stiffness between 620 and 630 Nm/rad. 2022-03 Thesis NonPeerReviewed image/jpeg http://studentsrepo.um.edu.my/13627/1/Aufar_Syehan.jpg application/pdf http://studentsrepo.um.edu.my/13627/8/aufar.pdf Aufar, Syehan (2022) Design and preliminary finite element analysis of planar rotary spring for BioApps RoMicP® ankle-foot prosthesis / Aufar Syehan. Masters thesis, Universiti Malaya. http://studentsrepo.um.edu.my/13627/
spellingShingle R Medicine (General)
T Technology (General)
Aufar, Syehan
Design and preliminary finite element analysis of planar rotary spring for BioApps RoMicP® ankle-foot prosthesis / Aufar Syehan
title Design and preliminary finite element analysis of planar rotary spring for BioApps RoMicP® ankle-foot prosthesis / Aufar Syehan
title_full Design and preliminary finite element analysis of planar rotary spring for BioApps RoMicP® ankle-foot prosthesis / Aufar Syehan
title_fullStr Design and preliminary finite element analysis of planar rotary spring for BioApps RoMicP® ankle-foot prosthesis / Aufar Syehan
title_full_unstemmed Design and preliminary finite element analysis of planar rotary spring for BioApps RoMicP® ankle-foot prosthesis / Aufar Syehan
title_short Design and preliminary finite element analysis of planar rotary spring for BioApps RoMicP® ankle-foot prosthesis / Aufar Syehan
title_sort design and preliminary finite element analysis of planar rotary spring for bioapps romicp® ankle-foot prosthesis / aufar syehan
topic R Medicine (General)
T Technology (General)
url http://studentsrepo.um.edu.my/13627/
http://studentsrepo.um.edu.my/13627/1/Aufar_Syehan.jpg
http://studentsrepo.um.edu.my/13627/8/aufar.pdf