The effect of reconstruction parameters on trabecular bone microstructure assessment using cone beam computed tomography dataset / Aso Muhammad Ali Muhammad

Cone beam computed tomography (CBCT) system is a broadly used imaging modality in dentistry nowadays. It allows the imaging of high contrast structures of the oral region at a high resolution. The effect of CBCT scan parameters on trabecular bone microstructure (Tb.N), (Tb.Th), (Tb.Sp), and (BV/T...

Full description

Bibliographic Details
Main Author: Aso Muhammad, Ali Muhammad
Format: Thesis
Published: 2019
Subjects:
Online Access:http://studentsrepo.um.edu.my/10437/
http://studentsrepo.um.edu.my/10437/4/aso.pdf
_version_ 1848774137894404096
author Aso Muhammad, Ali Muhammad
author_facet Aso Muhammad, Ali Muhammad
author_sort Aso Muhammad, Ali Muhammad
building UM Research Repository
collection Online Access
description Cone beam computed tomography (CBCT) system is a broadly used imaging modality in dentistry nowadays. It allows the imaging of high contrast structures of the oral region at a high resolution. The effect of CBCT scan parameters on trabecular bone microstructure (Tb.N), (Tb.Th), (Tb.Sp), and (BV/TV) has been studied, while the effect of CBCT reconstruction parameters is still lacking. Five sectioned maxillae of adult Dorper male sheep (age ranging from 20-48 months and body weight 50-60 kg) were scanned using a CBCT system (Carestream 9000, Kodak) and a Micro-CT (μCT) system (SkyScan 1076, Kontich, Belgium). In the first part of this study, the images for μCT and CBCT were processed and analyzed to study the reliability of CBCT trabecular bone microstructure assessment in comparison with Micro-CT. In the second part of this study, the effect of CBCT reconstruction parameters (reconstruction voxel size, threshold value, and the size and content of the region of interest) on trabecular bone microstructure assessment were evaluated. The statistical analysis showed that CBCT is reliable for the trabecular microstructure measurement in comparison with μCT. For the reconstruction voxel size, there was no significant difference between different reconstruction voxel sizes (76, 100, and 200 μm3 ). For the threshold value, an increase and decrease in the chosen optimal value by 15% was done. Decreasing the chosen optimal value (by 15%) showed significant difference on all trabecular bone parameters, whereas increasing the value had no significant effect. Lastly, the region of interest (Group 1, ROI that only contained trabecular bone, Group 2, ROI contained cortical bone and trabecular bone) showed the inclusion of cortical bone in the ROI showed significant difference on the Tb.Th and BV/TV measurements. In conclusion, BONE MICROSTRUCTURE ASSESSMENT USING CONE BEAM COMPUTED TOMOGRAPHY DATASET iv CBCT (Carestream 9000, Kodak) is reliable for the trabecular bone microstructure assessment. However, the selected CBCT reconstruction parameters can compromise the trabecular bone microstructure measurement
first_indexed 2025-11-14T13:53:32Z
format Thesis
id um-10437
institution University Malaya
institution_category Local University
last_indexed 2025-11-14T13:53:32Z
publishDate 2019
recordtype eprints
repository_type Digital Repository
spelling um-104372019-10-28T19:57:45Z The effect of reconstruction parameters on trabecular bone microstructure assessment using cone beam computed tomography dataset / Aso Muhammad Ali Muhammad Aso Muhammad, Ali Muhammad RK Dentistry Cone beam computed tomography (CBCT) system is a broadly used imaging modality in dentistry nowadays. It allows the imaging of high contrast structures of the oral region at a high resolution. The effect of CBCT scan parameters on trabecular bone microstructure (Tb.N), (Tb.Th), (Tb.Sp), and (BV/TV) has been studied, while the effect of CBCT reconstruction parameters is still lacking. Five sectioned maxillae of adult Dorper male sheep (age ranging from 20-48 months and body weight 50-60 kg) were scanned using a CBCT system (Carestream 9000, Kodak) and a Micro-CT (μCT) system (SkyScan 1076, Kontich, Belgium). In the first part of this study, the images for μCT and CBCT were processed and analyzed to study the reliability of CBCT trabecular bone microstructure assessment in comparison with Micro-CT. In the second part of this study, the effect of CBCT reconstruction parameters (reconstruction voxel size, threshold value, and the size and content of the region of interest) on trabecular bone microstructure assessment were evaluated. The statistical analysis showed that CBCT is reliable for the trabecular microstructure measurement in comparison with μCT. For the reconstruction voxel size, there was no significant difference between different reconstruction voxel sizes (76, 100, and 200 μm3 ). For the threshold value, an increase and decrease in the chosen optimal value by 15% was done. Decreasing the chosen optimal value (by 15%) showed significant difference on all trabecular bone parameters, whereas increasing the value had no significant effect. Lastly, the region of interest (Group 1, ROI that only contained trabecular bone, Group 2, ROI contained cortical bone and trabecular bone) showed the inclusion of cortical bone in the ROI showed significant difference on the Tb.Th and BV/TV measurements. In conclusion, BONE MICROSTRUCTURE ASSESSMENT USING CONE BEAM COMPUTED TOMOGRAPHY DATASET iv CBCT (Carestream 9000, Kodak) is reliable for the trabecular bone microstructure assessment. However, the selected CBCT reconstruction parameters can compromise the trabecular bone microstructure measurement 2019 Thesis NonPeerReviewed application/pdf http://studentsrepo.um.edu.my/10437/4/aso.pdf Aso Muhammad, Ali Muhammad (2019) The effect of reconstruction parameters on trabecular bone microstructure assessment using cone beam computed tomography dataset / Aso Muhammad Ali Muhammad. Masters thesis, University of Malaya. http://studentsrepo.um.edu.my/10437/
spellingShingle RK Dentistry
Aso Muhammad, Ali Muhammad
The effect of reconstruction parameters on trabecular bone microstructure assessment using cone beam computed tomography dataset / Aso Muhammad Ali Muhammad
title The effect of reconstruction parameters on trabecular bone microstructure assessment using cone beam computed tomography dataset / Aso Muhammad Ali Muhammad
title_full The effect of reconstruction parameters on trabecular bone microstructure assessment using cone beam computed tomography dataset / Aso Muhammad Ali Muhammad
title_fullStr The effect of reconstruction parameters on trabecular bone microstructure assessment using cone beam computed tomography dataset / Aso Muhammad Ali Muhammad
title_full_unstemmed The effect of reconstruction parameters on trabecular bone microstructure assessment using cone beam computed tomography dataset / Aso Muhammad Ali Muhammad
title_short The effect of reconstruction parameters on trabecular bone microstructure assessment using cone beam computed tomography dataset / Aso Muhammad Ali Muhammad
title_sort effect of reconstruction parameters on trabecular bone microstructure assessment using cone beam computed tomography dataset / aso muhammad ali muhammad
topic RK Dentistry
url http://studentsrepo.um.edu.my/10437/
http://studentsrepo.um.edu.my/10437/4/aso.pdf