Computational Fluid Dynamics (CFD) of aneurysmatic blood vessel / Masri Zairi Mohd Zin

Blood flow dynamics plays an important role in the development of aneurysms. An aneurysm is a permanent ballooning in the wall of an artery. The pressure of blood passing through can force part of a weakened artery to bulge outward, forming a thin-skinned blister. This study is to analyze the Comput...

Full description

Bibliographic Details
Main Author: Mohd Zin, Masri Zairi
Format: Thesis
Language:English
Published: 2010
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/36402/
_version_ 1848809042597642240
author Mohd Zin, Masri Zairi
author_facet Mohd Zin, Masri Zairi
author_sort Mohd Zin, Masri Zairi
building UiTM Institutional Repository
collection Online Access
description Blood flow dynamics plays an important role in the development of aneurysms. An aneurysm is a permanent ballooning in the wall of an artery. The pressure of blood passing through can force part of a weakened artery to bulge outward, forming a thin-skinned blister. This study is to analyze the Computational Fluid Dynamics (CFD) of aneurysmatic blood vessel in two representative models of a terminal aneurysm of the basilar artery, and compares their wall shear stress, pressure, velocity and streamline flow with that of a healthy basilar artery. Aneurysm models are investigated numerically, with geometric features defined by /? =0 deg and (3 =23.2 deg, where /? is the tilt angle of the aneurysm sac with respect to the basilar artery. The arterial wall was assumed to be elastic, isotropic, incompressible and homogeneous. The flow was assumed to be laminar, Newtonian, and incompressible. The fluid and structure models were solved with the FLUENTANSYS 12.1. The pressure and wall shear stress on the aneurysm wall exhibit large spatial variations for the model. Aneurysm model 2- /? = 23.2 deg has higher and stable vorticity than aneurysm model 1- /? = 0 deg. For healthy basilar artery model there was no vortices. The aneurysm model 2- /? = 23.2 deg also has higher wall shear stress and pressure value than aneurysm model 1- /? = 0 deg in the aneurysm sac.
first_indexed 2025-11-14T23:08:19Z
format Thesis
id uitm-36402
institution Universiti Teknologi MARA
institution_category Local University
language English
last_indexed 2025-11-14T23:08:19Z
publishDate 2010
recordtype eprints
repository_type Digital Repository
spelling uitm-364022020-11-09T07:38:46Z https://ir.uitm.edu.my/id/eprint/36402/ Computational Fluid Dynamics (CFD) of aneurysmatic blood vessel / Masri Zairi Mohd Zin Mohd Zin, Masri Zairi Biomedical engineering Robotics. Robots. Manipulators (Mechanism) Machine design and drawing Blood flow dynamics plays an important role in the development of aneurysms. An aneurysm is a permanent ballooning in the wall of an artery. The pressure of blood passing through can force part of a weakened artery to bulge outward, forming a thin-skinned blister. This study is to analyze the Computational Fluid Dynamics (CFD) of aneurysmatic blood vessel in two representative models of a terminal aneurysm of the basilar artery, and compares their wall shear stress, pressure, velocity and streamline flow with that of a healthy basilar artery. Aneurysm models are investigated numerically, with geometric features defined by /? =0 deg and (3 =23.2 deg, where /? is the tilt angle of the aneurysm sac with respect to the basilar artery. The arterial wall was assumed to be elastic, isotropic, incompressible and homogeneous. The flow was assumed to be laminar, Newtonian, and incompressible. The fluid and structure models were solved with the FLUENTANSYS 12.1. The pressure and wall shear stress on the aneurysm wall exhibit large spatial variations for the model. Aneurysm model 2- /? = 23.2 deg has higher and stable vorticity than aneurysm model 1- /? = 0 deg. For healthy basilar artery model there was no vortices. The aneurysm model 2- /? = 23.2 deg also has higher wall shear stress and pressure value than aneurysm model 1- /? = 0 deg in the aneurysm sac. 2010 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/36402/1/36402.pdf Mohd Zin, Masri Zairi (2010) Computational Fluid Dynamics (CFD) of aneurysmatic blood vessel / Masri Zairi Mohd Zin. (2010) Degree thesis, thesis, Universiti Teknologi MARA.
spellingShingle Biomedical engineering
Robotics. Robots. Manipulators (Mechanism)
Machine design and drawing
Mohd Zin, Masri Zairi
Computational Fluid Dynamics (CFD) of aneurysmatic blood vessel / Masri Zairi Mohd Zin
title Computational Fluid Dynamics (CFD) of aneurysmatic blood vessel / Masri Zairi Mohd Zin
title_full Computational Fluid Dynamics (CFD) of aneurysmatic blood vessel / Masri Zairi Mohd Zin
title_fullStr Computational Fluid Dynamics (CFD) of aneurysmatic blood vessel / Masri Zairi Mohd Zin
title_full_unstemmed Computational Fluid Dynamics (CFD) of aneurysmatic blood vessel / Masri Zairi Mohd Zin
title_short Computational Fluid Dynamics (CFD) of aneurysmatic blood vessel / Masri Zairi Mohd Zin
title_sort computational fluid dynamics (cfd) of aneurysmatic blood vessel / masri zairi mohd zin
topic Biomedical engineering
Robotics. Robots. Manipulators (Mechanism)
Machine design and drawing
url https://ir.uitm.edu.my/id/eprint/36402/