Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron
Phenol as in water is harmful to living organism yet have a toxicity effect for a long-term exposure. In this research, the analysis was achieved on a C18 column coupled with UV-vis detector (HPLC-UV) for determination of phenol in environmental water while by using solid phase extraction (SPE) as s...
| Main Author: | |
|---|---|
| Format: | Student Project |
| Language: | English |
| Published: |
2017
|
| Subjects: | |
| Online Access: | https://ir.uitm.edu.my/id/eprint/35055/ |
| _version_ | 1848808694719971328 |
|---|---|
| author | Haron, Nazurah |
| author_facet | Haron, Nazurah |
| author_sort | Haron, Nazurah |
| building | UiTM Institutional Repository |
| collection | Online Access |
| description | Phenol as in water is harmful to living organism yet have a toxicity effect for a long-term exposure. In this research, the analysis was achieved on a C18 column coupled with UV-vis detector (HPLC-UV) for determination of phenol in environmental water while by using solid phase extraction (SPE) as sample preparation technique. The optimized variable involved in SPE and HPLC were as follow: 3 mL was used for load sample volume in SPE, 45 ± 3 drops min-1 was used for sample drop-rate in SPE and 0.35 mL min-1 as flow-rate on eluent in HPLC. The analytical method was validated based on the following parameter: precision, linear range, limit of detection (LOD), limit of quantitation (LOQ) and bias/recovery. A good linear correlation coefficient with R2 = 0.9996 was observed over the range of 0.55 - 30.0 µg mL-1. Both repeatability and reproducibility (RSD, %) were 0.215 and 1.490, respectively. The limit of detection was calculated to be 0.212 µg mL-1, while the limit of quantitation value of the validated method was measured to be 0.642 µg mL-1. Good recoveries were between 81 - 120%. The proposed method was found to be suitable and precise for the determination of phenol in environmental water by using HPLC. |
| first_indexed | 2025-11-14T23:02:48Z |
| format | Student Project |
| id | uitm-35055 |
| institution | Universiti Teknologi MARA |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-14T23:02:48Z |
| publishDate | 2017 |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | uitm-350552020-10-12T04:18:51Z https://ir.uitm.edu.my/id/eprint/35055/ Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron Haron, Nazurah Laboratories. General works Extraction (Chemistry) Phenol as in water is harmful to living organism yet have a toxicity effect for a long-term exposure. In this research, the analysis was achieved on a C18 column coupled with UV-vis detector (HPLC-UV) for determination of phenol in environmental water while by using solid phase extraction (SPE) as sample preparation technique. The optimized variable involved in SPE and HPLC were as follow: 3 mL was used for load sample volume in SPE, 45 ± 3 drops min-1 was used for sample drop-rate in SPE and 0.35 mL min-1 as flow-rate on eluent in HPLC. The analytical method was validated based on the following parameter: precision, linear range, limit of detection (LOD), limit of quantitation (LOQ) and bias/recovery. A good linear correlation coefficient with R2 = 0.9996 was observed over the range of 0.55 - 30.0 µg mL-1. Both repeatability and reproducibility (RSD, %) were 0.215 and 1.490, respectively. The limit of detection was calculated to be 0.212 µg mL-1, while the limit of quantitation value of the validated method was measured to be 0.642 µg mL-1. Good recoveries were between 81 - 120%. The proposed method was found to be suitable and precise for the determination of phenol in environmental water by using HPLC. 2017 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/35055/1/35055.pdf Haron, Nazurah (2017) Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron. (2017) [Student Project] (Unpublished) |
| spellingShingle | Laboratories. General works Extraction (Chemistry) Haron, Nazurah Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
| title | Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
| title_full | Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
| title_fullStr | Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
| title_full_unstemmed | Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
| title_short | Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
| title_sort | determination of phenol in water sample using high performance liquid chromatography / nazurah haron |
| topic | Laboratories. General works Extraction (Chemistry) |
| url | https://ir.uitm.edu.my/id/eprint/35055/ |