Improving overall thermal transfer value of office tower building in Malaysia, case study : Ministry of Women Family and Community Development, Lot 4G11, Putrajaya / Azman Zainonabidin and Amirul Amin Ismail

This paper presents the Overall Thermal Transfer Value (OTTV) and the energy consumption of air-conditioned office building in Malaysia. The study have been conducted to investigate the OTTV of Ministry of Women Family and Community Development’s office block at Lot 4G11, Putrajaya. OTTV calculatio...

Full description

Bibliographic Details
Main Authors: Azman, Zainonabidin, Amirul Amin, Ismail
Format: Conference or Workshop Item
Language:English
Published: 2015
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/32701/
_version_ 1848808091781431296
author Azman, Zainonabidin
Amirul Amin, Ismail
author_facet Azman, Zainonabidin
Amirul Amin, Ismail
author_sort Azman, Zainonabidin
building UiTM Institutional Repository
collection Online Access
description This paper presents the Overall Thermal Transfer Value (OTTV) and the energy consumption of air-conditioned office building in Malaysia. The study have been conducted to investigate the OTTV of Ministry of Women Family and Community Development’s office block at Lot 4G11, Putrajaya. OTTV calculation, energy consumption and effect of the building parameters on energy consumption have been investigated. OTTV formula in MS1525 and Green Building Index (GBI) rating tool have been used for the OTTV calculation. The study shown that the OTTV of the Lot 4G11 is more than 70W/m2. In order to comply with MS1525, where the minimum OTTV shall be less than 50W/m2, improvement of the building envelope have been proposed, and the OTTV have been reduced below 50W/m 2 . Since the Government has set that all government buildings in Putrajaya shall be GBI certified, further improvement of building envelope have been made in order to achieve OTTV for Platinum certification. It is found that improving the Window to Wall Ratio (WWR), Shading Coefficient (SC) and U-value for glazing will further reduce the OTTV and improve the energy efficiency of the Lot 4G11. Detailed calculations have been conducted to compare the results in between Building Baseline, MS1525 and Platinum Design.
first_indexed 2025-11-14T22:53:13Z
format Conference or Workshop Item
id uitm-32701
institution Universiti Teknologi MARA
institution_category Local University
language English
last_indexed 2025-11-14T22:53:13Z
publishDate 2015
recordtype eprints
repository_type Digital Repository
spelling uitm-327012020-07-27T04:19:18Z https://ir.uitm.edu.my/id/eprint/32701/ Improving overall thermal transfer value of office tower building in Malaysia, case study : Ministry of Women Family and Community Development, Lot 4G11, Putrajaya / Azman Zainonabidin and Amirul Amin Ismail Azman, Zainonabidin Amirul Amin, Ismail Power resources Energy conservation This paper presents the Overall Thermal Transfer Value (OTTV) and the energy consumption of air-conditioned office building in Malaysia. The study have been conducted to investigate the OTTV of Ministry of Women Family and Community Development’s office block at Lot 4G11, Putrajaya. OTTV calculation, energy consumption and effect of the building parameters on energy consumption have been investigated. OTTV formula in MS1525 and Green Building Index (GBI) rating tool have been used for the OTTV calculation. The study shown that the OTTV of the Lot 4G11 is more than 70W/m2. In order to comply with MS1525, where the minimum OTTV shall be less than 50W/m2, improvement of the building envelope have been proposed, and the OTTV have been reduced below 50W/m 2 . Since the Government has set that all government buildings in Putrajaya shall be GBI certified, further improvement of building envelope have been made in order to achieve OTTV for Platinum certification. It is found that improving the Window to Wall Ratio (WWR), Shading Coefficient (SC) and U-value for glazing will further reduce the OTTV and improve the energy efficiency of the Lot 4G11. Detailed calculations have been conducted to compare the results in between Building Baseline, MS1525 and Platinum Design. 2015 Conference or Workshop Item PeerReviewed text en https://ir.uitm.edu.my/id/eprint/32701/1/32701.pdf Azman, Zainonabidin and Amirul Amin, Ismail (2015) Improving overall thermal transfer value of office tower building in Malaysia, case study : Ministry of Women Family and Community Development, Lot 4G11, Putrajaya / Azman Zainonabidin and Amirul Amin Ismail. (2015) In: Proceedings of Postgraduate Conference on Global Green Issues (Go Green), 7-8 October 2015, Dewan Kuliah Al-Khawarizmi Universiti Teknologi MARA Cawangan Perak.
spellingShingle Power resources
Energy conservation
Azman, Zainonabidin
Amirul Amin, Ismail
Improving overall thermal transfer value of office tower building in Malaysia, case study : Ministry of Women Family and Community Development, Lot 4G11, Putrajaya / Azman Zainonabidin and Amirul Amin Ismail
title Improving overall thermal transfer value of office tower building in Malaysia, case study : Ministry of Women Family and Community Development, Lot 4G11, Putrajaya / Azman Zainonabidin and Amirul Amin Ismail
title_full Improving overall thermal transfer value of office tower building in Malaysia, case study : Ministry of Women Family and Community Development, Lot 4G11, Putrajaya / Azman Zainonabidin and Amirul Amin Ismail
title_fullStr Improving overall thermal transfer value of office tower building in Malaysia, case study : Ministry of Women Family and Community Development, Lot 4G11, Putrajaya / Azman Zainonabidin and Amirul Amin Ismail
title_full_unstemmed Improving overall thermal transfer value of office tower building in Malaysia, case study : Ministry of Women Family and Community Development, Lot 4G11, Putrajaya / Azman Zainonabidin and Amirul Amin Ismail
title_short Improving overall thermal transfer value of office tower building in Malaysia, case study : Ministry of Women Family and Community Development, Lot 4G11, Putrajaya / Azman Zainonabidin and Amirul Amin Ismail
title_sort improving overall thermal transfer value of office tower building in malaysia, case study : ministry of women family and community development, lot 4g11, putrajaya / azman zainonabidin and amirul amin ismail
topic Power resources
Energy conservation
url https://ir.uitm.edu.my/id/eprint/32701/