Optimization of exposure parameters in automatic optimization of exposure parameters (Aop) mode of full field digital mammography (FFDM) system: breast phantom study / Hairenanorashikin Sharip and Rafidah Supar
This experimental study investigated the significant different in image quality and dose between different automatic exposure of exposure parameter (AOP) mode in full field digital mammography (FFDM) system. CIRS012A and PMMA breast phantom (4cm, 5cm and 6 cm thickness) were used as subject using Se...
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Universiti Teknologi MARA, Negeri Sembilan
2020
|
| Subjects: | |
| Online Access: | https://ir.uitm.edu.my/id/eprint/31987/ |
| _version_ | 1848807905000685568 |
|---|---|
| author | Sharip, Hairenanorashikin Supar, Rafidah |
| author_facet | Sharip, Hairenanorashikin Supar, Rafidah |
| author_sort | Sharip, Hairenanorashikin |
| building | UiTM Institutional Repository |
| collection | Online Access |
| description | This experimental study investigated the significant different in image quality and dose between different automatic exposure of exposure parameter (AOP) mode in full field digital mammography (FFDM) system. CIRS012A and PMMA breast phantom (4cm, 5cm and 6 cm thickness) were used as subject using Senographe Essential FFDM system. TLD chip was used as dose measurement tool. Exposures were taken in cranio-caudal projection. 2 radiographers with more than 10 years of working experience in performing mammography scored the image independently. Kappa finds a good agreement between raters (kappa value=0.9, p<0.01). One-way ANOVA shows a significant different in dose between CNT and DOSE mode (p=0.013). However, there is no significant different in image quality between CNT, DOSE and STD (p>0.05). DOSE mode is the preferred selection in optimizing between dose and image quality. |
| first_indexed | 2025-11-14T22:50:14Z |
| format | Article |
| id | uitm-31987 |
| institution | Universiti Teknologi MARA |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-14T22:50:14Z |
| publishDate | 2020 |
| publisher | Universiti Teknologi MARA, Negeri Sembilan |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | uitm-319872020-07-15T07:18:38Z https://ir.uitm.edu.my/id/eprint/31987/ Optimization of exposure parameters in automatic optimization of exposure parameters (Aop) mode of full field digital mammography (FFDM) system: breast phantom study / Hairenanorashikin Sharip and Rafidah Supar joa Sharip, Hairenanorashikin Supar, Rafidah Statistical methods Medical technology This experimental study investigated the significant different in image quality and dose between different automatic exposure of exposure parameter (AOP) mode in full field digital mammography (FFDM) system. CIRS012A and PMMA breast phantom (4cm, 5cm and 6 cm thickness) were used as subject using Senographe Essential FFDM system. TLD chip was used as dose measurement tool. Exposures were taken in cranio-caudal projection. 2 radiographers with more than 10 years of working experience in performing mammography scored the image independently. Kappa finds a good agreement between raters (kappa value=0.9, p<0.01). One-way ANOVA shows a significant different in dose between CNT and DOSE mode (p=0.013). However, there is no significant different in image quality between CNT, DOSE and STD (p>0.05). DOSE mode is the preferred selection in optimizing between dose and image quality. Universiti Teknologi MARA, Negeri Sembilan 2020 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/31987/1/31987.pdf Sharip, Hairenanorashikin and Supar, Rafidah (2020) Optimization of exposure parameters in automatic optimization of exposure parameters (Aop) mode of full field digital mammography (FFDM) system: breast phantom study / Hairenanorashikin Sharip and Rafidah Supar. (2020) Journal of Academia <https://ir.uitm.edu.my/view/publication/Journal_of_Academia.html>, 8 (1). pp. 18-23. ISSN 2289-6368 https://nsembilan.uitm.edu.my/joacns/ |
| spellingShingle | Statistical methods Medical technology Sharip, Hairenanorashikin Supar, Rafidah Optimization of exposure parameters in automatic optimization of exposure parameters (Aop) mode of full field digital mammography (FFDM) system: breast phantom study / Hairenanorashikin Sharip and Rafidah Supar |
| title | Optimization of exposure parameters in automatic optimization of exposure parameters (Aop) mode of full field digital mammography (FFDM) system: breast phantom study / Hairenanorashikin Sharip and Rafidah Supar |
| title_full | Optimization of exposure parameters in automatic optimization of exposure parameters (Aop) mode of full field digital mammography (FFDM) system: breast phantom study / Hairenanorashikin Sharip and Rafidah Supar |
| title_fullStr | Optimization of exposure parameters in automatic optimization of exposure parameters (Aop) mode of full field digital mammography (FFDM) system: breast phantom study / Hairenanorashikin Sharip and Rafidah Supar |
| title_full_unstemmed | Optimization of exposure parameters in automatic optimization of exposure parameters (Aop) mode of full field digital mammography (FFDM) system: breast phantom study / Hairenanorashikin Sharip and Rafidah Supar |
| title_short | Optimization of exposure parameters in automatic optimization of exposure parameters (Aop) mode of full field digital mammography (FFDM) system: breast phantom study / Hairenanorashikin Sharip and Rafidah Supar |
| title_sort | optimization of exposure parameters in automatic optimization of exposure parameters (aop) mode of full field digital mammography (ffdm) system: breast phantom study / hairenanorashikin sharip and rafidah supar |
| topic | Statistical methods Medical technology |
| url | https://ir.uitm.edu.my/id/eprint/31987/ https://ir.uitm.edu.my/id/eprint/31987/ |