Seismic Perfromance On Multi-Storey Precast Buildings (IBS) In Malaysia Subjected To Long-Distant Earthquake Excitation / Nor Hayati Abdul Hamid … [et_al.]

Seismic performance of the reinforced concrete buildings in Malaysia need to examine their structural components under earthquakes excitation. The sub-assemblage of fullscale precast hollow core slabs together with supporting beams are designed, constructed, calibrated and tested under vertical cycl...

Full description

Bibliographic Details
Main Authors: Abdul Hamid, Nor Hayati, Hamzah, Siti Hawa, Rosli@Rozli, Mohd Ikmal Fazlan, Mohd Amin, Norliyati
Format: Research Reports
Language:English
Published: Research Management Institute (RMI) 2010
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/27171/
_version_ 1848806704105390080
author Abdul Hamid, Nor Hayati
Hamzah, Siti Hawa
Rosli@Rozli, Mohd Ikmal Fazlan
Mohd Amin, Norliyati
author_facet Abdul Hamid, Nor Hayati
Hamzah, Siti Hawa
Rosli@Rozli, Mohd Ikmal Fazlan
Mohd Amin, Norliyati
author_sort Abdul Hamid, Nor Hayati
building UiTM Institutional Repository
collection Online Access
description Seismic performance of the reinforced concrete buildings in Malaysia need to examine their structural components under earthquakes excitation. The sub-assemblage of fullscale precast hollow core slabs together with supporting beams are designed, constructed, calibrated and tested under vertical cyclic loadings. The incremental drifts are applied at the end of the cantilever slabs. The load failure, mode of failure and structural damages are recorded and observed during experimental work. Initially, the cracks start from the joints and propagated on top of the slabs and finally, the slab snapped at middle together with delimination of the bottom fibre of the slab. Another experimental work is conducted on three sets of half-scale beam-column joint with different arrangements of reinforcement bars at the joints. These specimens are attached to the foundation beams and clamped to strong floor using eight high yield threaded rods of diameters 30mm. The specimens are designed, constructed and tested under reversible vertical cyclic loading until collapse. The joint with cross-bracing suffers the least damage as compare to others joints. By using the same specimens, the next step is to design the column-foundation joints under lateral cyclic loadings. Tension lateral cyclic loading is applied at top of the column with drifts of 0.1%, 0.2%, 0.3%, 0.4%, 0.5%, 1.0%, 1.5%, 2.0% and 2.5% at 2 cycles for each drift. Similar pattern of cracks and damages observed during experimental work as compared to the actual damages occurred during earthquake excitation. The first damage is due to unconfined concrete occurred between foundation beam and beamcolumn joint. The second damage is due to plastic hinge zone mechanism which occurs at column-foundation interfaces. These damages are due to the insufficient of longitudinal bars, the spacing between the stirrups are wider and spalling of concrete (low
first_indexed 2025-11-14T22:31:09Z
format Research Reports
id uitm-27171
institution Universiti Teknologi MARA
institution_category Local University
language English
last_indexed 2025-11-14T22:31:09Z
publishDate 2010
publisher Research Management Institute (RMI)
recordtype eprints
repository_type Digital Repository
spelling uitm-271712023-01-12T08:05:46Z https://ir.uitm.edu.my/id/eprint/27171/ Seismic Perfromance On Multi-Storey Precast Buildings (IBS) In Malaysia Subjected To Long-Distant Earthquake Excitation / Nor Hayati Abdul Hamid … [et_al.] Abdul Hamid, Nor Hayati Hamzah, Siti Hawa Rosli@Rozli, Mohd Ikmal Fazlan Mohd Amin, Norliyati Environmental conditions. Environmental quality. Environmental indicators. Environmental degradation TD Environmental technology. Sanitary engineering Environmental protection Seismic performance of the reinforced concrete buildings in Malaysia need to examine their structural components under earthquakes excitation. The sub-assemblage of fullscale precast hollow core slabs together with supporting beams are designed, constructed, calibrated and tested under vertical cyclic loadings. The incremental drifts are applied at the end of the cantilever slabs. The load failure, mode of failure and structural damages are recorded and observed during experimental work. Initially, the cracks start from the joints and propagated on top of the slabs and finally, the slab snapped at middle together with delimination of the bottom fibre of the slab. Another experimental work is conducted on three sets of half-scale beam-column joint with different arrangements of reinforcement bars at the joints. These specimens are attached to the foundation beams and clamped to strong floor using eight high yield threaded rods of diameters 30mm. The specimens are designed, constructed and tested under reversible vertical cyclic loading until collapse. The joint with cross-bracing suffers the least damage as compare to others joints. By using the same specimens, the next step is to design the column-foundation joints under lateral cyclic loadings. Tension lateral cyclic loading is applied at top of the column with drifts of 0.1%, 0.2%, 0.3%, 0.4%, 0.5%, 1.0%, 1.5%, 2.0% and 2.5% at 2 cycles for each drift. Similar pattern of cracks and damages observed during experimental work as compared to the actual damages occurred during earthquake excitation. The first damage is due to unconfined concrete occurred between foundation beam and beamcolumn joint. The second damage is due to plastic hinge zone mechanism which occurs at column-foundation interfaces. These damages are due to the insufficient of longitudinal bars, the spacing between the stirrups are wider and spalling of concrete (low Research Management Institute (RMI) 2010-05 Research Reports NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/27171/1/LP_NOR%20HAYATI%20ABDUL%20HAMID%20RMI%2010_5.pdf Abdul Hamid, Nor Hayati and Hamzah, Siti Hawa and Rosli@Rozli, Mohd Ikmal Fazlan and Mohd Amin, Norliyati (2010) Seismic Perfromance On Multi-Storey Precast Buildings (IBS) In Malaysia Subjected To Long-Distant Earthquake Excitation / Nor Hayati Abdul Hamid … [et_al.]. (2010) [Research Reports] <http://terminalib.uitm.edu.my/27171.pdf> (Unpublished)
spellingShingle Environmental conditions. Environmental quality. Environmental indicators. Environmental degradation
TD Environmental technology. Sanitary engineering
Environmental protection
Abdul Hamid, Nor Hayati
Hamzah, Siti Hawa
Rosli@Rozli, Mohd Ikmal Fazlan
Mohd Amin, Norliyati
Seismic Perfromance On Multi-Storey Precast Buildings (IBS) In Malaysia Subjected To Long-Distant Earthquake Excitation / Nor Hayati Abdul Hamid … [et_al.]
title Seismic Perfromance On Multi-Storey Precast Buildings (IBS) In Malaysia Subjected To Long-Distant Earthquake Excitation / Nor Hayati Abdul Hamid … [et_al.]
title_full Seismic Perfromance On Multi-Storey Precast Buildings (IBS) In Malaysia Subjected To Long-Distant Earthquake Excitation / Nor Hayati Abdul Hamid … [et_al.]
title_fullStr Seismic Perfromance On Multi-Storey Precast Buildings (IBS) In Malaysia Subjected To Long-Distant Earthquake Excitation / Nor Hayati Abdul Hamid … [et_al.]
title_full_unstemmed Seismic Perfromance On Multi-Storey Precast Buildings (IBS) In Malaysia Subjected To Long-Distant Earthquake Excitation / Nor Hayati Abdul Hamid … [et_al.]
title_short Seismic Perfromance On Multi-Storey Precast Buildings (IBS) In Malaysia Subjected To Long-Distant Earthquake Excitation / Nor Hayati Abdul Hamid … [et_al.]
title_sort seismic perfromance on multi-storey precast buildings (ibs) in malaysia subjected to long-distant earthquake excitation / nor hayati abdul hamid … [et_al.]
topic Environmental conditions. Environmental quality. Environmental indicators. Environmental degradation
TD Environmental technology. Sanitary engineering
Environmental protection
url https://ir.uitm.edu.my/id/eprint/27171/