Study on the flow rate and initial oven temperature of gc-fid using pesticide analysis / Imran Hakimie Jamalludin

Gas Chromatography Flame Ionisation Detector (GC-FID) has been used in this study to determine the optimum initial oven temperature and carrier gas flow rate using three different Organophosphorus pesticides (OPPs) namely as vinclozolin, malathion and methidathion. A non-polar of HP-5 column was use...

Full description

Bibliographic Details
Main Author: Jamalludin, Imran Hakimie
Format: Student Project
Language:English
Published: Faculty of Applied Sciences 2016
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/24268/
_version_ 1848805943297441792
author Jamalludin, Imran Hakimie
author_facet Jamalludin, Imran Hakimie
author_sort Jamalludin, Imran Hakimie
building UiTM Institutional Repository
collection Online Access
description Gas Chromatography Flame Ionisation Detector (GC-FID) has been used in this study to determine the optimum initial oven temperature and carrier gas flow rate using three different Organophosphorus pesticides (OPPs) namely as vinclozolin, malathion and methidathion. A non-polar of HP-5 column was used as the injector and detector temperature were both set at 300°C using 1 μL injection volume. The initial oven temperature and carrier gas flow rate were ranged from 60°C to 110°C and 2 mL min-1 to 6 mL min-1 respectively. In the determination of the optimuminitial oven temperature and carrier gas flow rate, 90°C and 5 mL min-1 of theinitial oven temperature and carrier gas flow rate were fixed respectively. For the study on the effect of isothermal temperature, the temperatures were ranged from 150°C to 270°C. In this study, 90°C and 5 were chosen as the optimum initial oven temperature and carrier gas flow rate respectively as it based on the highest percentage of peak area of the pesticides. For the effect of isothermal temperature, 150°C, 180°C and 210°C were chosen as the best temperature as it showed highest in percentage of peak area for vinclozolin, malathion and methidathion respectively.
first_indexed 2025-11-14T22:19:04Z
format Student Project
id uitm-24268
institution Universiti Teknologi MARA
institution_category Local University
language English
last_indexed 2025-11-14T22:19:04Z
publishDate 2016
publisher Faculty of Applied Sciences
recordtype eprints
repository_type Digital Repository
spelling uitm-242682019-05-23T07:55:51Z https://ir.uitm.edu.my/id/eprint/24268/ Study on the flow rate and initial oven temperature of gc-fid using pesticide analysis / Imran Hakimie Jamalludin Jamalludin, Imran Hakimie QD Chemistry Gas Chromatography Flame Ionisation Detector (GC-FID) has been used in this study to determine the optimum initial oven temperature and carrier gas flow rate using three different Organophosphorus pesticides (OPPs) namely as vinclozolin, malathion and methidathion. A non-polar of HP-5 column was used as the injector and detector temperature were both set at 300°C using 1 μL injection volume. The initial oven temperature and carrier gas flow rate were ranged from 60°C to 110°C and 2 mL min-1 to 6 mL min-1 respectively. In the determination of the optimuminitial oven temperature and carrier gas flow rate, 90°C and 5 mL min-1 of theinitial oven temperature and carrier gas flow rate were fixed respectively. For the study on the effect of isothermal temperature, the temperatures were ranged from 150°C to 270°C. In this study, 90°C and 5 were chosen as the optimum initial oven temperature and carrier gas flow rate respectively as it based on the highest percentage of peak area of the pesticides. For the effect of isothermal temperature, 150°C, 180°C and 210°C were chosen as the best temperature as it showed highest in percentage of peak area for vinclozolin, malathion and methidathion respectively. Faculty of Applied Sciences 2016 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/24268/1/PPb_IMRAN%20HAKIMIE%20JAMALLUDIN%20AS%20N%2016_5.pdf Jamalludin, Imran Hakimie (2016) Study on the flow rate and initial oven temperature of gc-fid using pesticide analysis / Imran Hakimie Jamalludin. (2016) [Student Project] <http://terminalib.uitm.edu.my/24268.pdf> (Unpublished)
spellingShingle QD Chemistry
Jamalludin, Imran Hakimie
Study on the flow rate and initial oven temperature of gc-fid using pesticide analysis / Imran Hakimie Jamalludin
title Study on the flow rate and initial oven temperature of gc-fid using pesticide analysis / Imran Hakimie Jamalludin
title_full Study on the flow rate and initial oven temperature of gc-fid using pesticide analysis / Imran Hakimie Jamalludin
title_fullStr Study on the flow rate and initial oven temperature of gc-fid using pesticide analysis / Imran Hakimie Jamalludin
title_full_unstemmed Study on the flow rate and initial oven temperature of gc-fid using pesticide analysis / Imran Hakimie Jamalludin
title_short Study on the flow rate and initial oven temperature of gc-fid using pesticide analysis / Imran Hakimie Jamalludin
title_sort study on the flow rate and initial oven temperature of gc-fid using pesticide analysis / imran hakimie jamalludin
topic QD Chemistry
url https://ir.uitm.edu.my/id/eprint/24268/