Studying thermal performance of split-type air conditioners at building re-entrant via computer simulation / Fauziah Jerai and Ow Chee Sheng
Split-type air conditioners used in residential or office buildings often have the outdoor condensing units install at the sidewalls. In condominium or apartment buildings, the building re-entrants are the most frequent choice of the project team for placing the outdoor air-cooled condensing units....
| Main Authors: | , |
|---|---|
| Format: | Research Reports |
| Language: | English |
| Published: |
Research Management Institute (RMI)
2011
|
| Subjects: | |
| Online Access: | https://ir.uitm.edu.my/id/eprint/21078/ |
| _version_ | 1848805156201693184 |
|---|---|
| author | Jerai, Fauziah Ow, Chee Sheng |
| author_facet | Jerai, Fauziah Ow, Chee Sheng |
| author_sort | Jerai, Fauziah |
| building | UiTM Institutional Repository |
| collection | Online Access |
| description | Split-type air conditioners used in residential or office buildings often have the outdoor condensing units install at the sidewalls. In condominium or apartment buildings, the building re-entrants are the most frequent choice of the project team for placing the outdoor air-cooled condensing units. To avoid wastage in electrical energy and unnecessarily heat rejection to the environment, the HVAC engineer and the team should predict the thermal effect on the air-conditioners usage from the layout design stage. Additionally, the layout design is also continuously changing before the final design stage and this enhances the difficulty for the team to estimate the actual effect of placing over a hundred outdoor units inside one single re-entrant of a high rise building. In order to tackle this problem, a simulation approach is applied using Computational Fluid Dynamics (CFD), (Phoenics v2008). The energy performances as well as the levels of thermal comfort for the proposed option were evaluated. |
| first_indexed | 2025-11-14T22:06:33Z |
| format | Research Reports |
| id | uitm-21078 |
| institution | Universiti Teknologi MARA |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-14T22:06:33Z |
| publishDate | 2011 |
| publisher | Research Management Institute (RMI) |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | uitm-210782018-08-20T07:38:21Z https://ir.uitm.edu.my/id/eprint/21078/ Studying thermal performance of split-type air conditioners at building re-entrant via computer simulation / Fauziah Jerai and Ow Chee Sheng Jerai, Fauziah Ow, Chee Sheng Air pollution and its control Control engineering systems. Automatic machinery (General) Split-type air conditioners used in residential or office buildings often have the outdoor condensing units install at the sidewalls. In condominium or apartment buildings, the building re-entrants are the most frequent choice of the project team for placing the outdoor air-cooled condensing units. To avoid wastage in electrical energy and unnecessarily heat rejection to the environment, the HVAC engineer and the team should predict the thermal effect on the air-conditioners usage from the layout design stage. Additionally, the layout design is also continuously changing before the final design stage and this enhances the difficulty for the team to estimate the actual effect of placing over a hundred outdoor units inside one single re-entrant of a high rise building. In order to tackle this problem, a simulation approach is applied using Computational Fluid Dynamics (CFD), (Phoenics v2008). The energy performances as well as the levels of thermal comfort for the proposed option were evaluated. Research Management Institute (RMI) 2011 Research Reports NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/21078/1/LP_FAUZIAH%20JERAI%20RMI%2011_5.pdf Jerai, Fauziah and Ow, Chee Sheng (2011) Studying thermal performance of split-type air conditioners at building re-entrant via computer simulation / Fauziah Jerai and Ow Chee Sheng. (2011) [Research Reports] <http://terminalib.uitm.edu.my/21078.pdf> (Unpublished) |
| spellingShingle | Air pollution and its control Control engineering systems. Automatic machinery (General) Jerai, Fauziah Ow, Chee Sheng Studying thermal performance of split-type air conditioners at building re-entrant via computer simulation / Fauziah Jerai and Ow Chee Sheng |
| title | Studying thermal performance of split-type air conditioners at building re-entrant via computer simulation / Fauziah Jerai and Ow Chee Sheng |
| title_full | Studying thermal performance of split-type air conditioners at building re-entrant via computer simulation / Fauziah Jerai and Ow Chee Sheng |
| title_fullStr | Studying thermal performance of split-type air conditioners at building re-entrant via computer simulation / Fauziah Jerai and Ow Chee Sheng |
| title_full_unstemmed | Studying thermal performance of split-type air conditioners at building re-entrant via computer simulation / Fauziah Jerai and Ow Chee Sheng |
| title_short | Studying thermal performance of split-type air conditioners at building re-entrant via computer simulation / Fauziah Jerai and Ow Chee Sheng |
| title_sort | studying thermal performance of split-type air conditioners at building re-entrant via computer simulation / fauziah jerai and ow chee sheng |
| topic | Air pollution and its control Control engineering systems. Automatic machinery (General) |
| url | https://ir.uitm.edu.my/id/eprint/21078/ |