Application of ULDF to determine maximum drop size produced by pneumatic atomiser / Fauziah Jerai@Junaidi and Ow Chee Sheng

Pneumatic atomisers are well suited to the production of sprays with average drop diameter less than 30fim mass mean diameter depending on the pressure used. The maximum size of the drops formed are a function of the design of the atomiser. In this study, droplet size in a pneumatic atomiser was mea...

Full description

Bibliographic Details
Format: Article
Language:English
Published: Faculty of Mechanical Engineering and University Publication Centre (UPENA) 2007
Online Access:https://ir.uitm.edu.my/id/eprint/17534/
_version_ 1848804297741959168
building UiTM Institutional Repository
collection Online Access
description Pneumatic atomisers are well suited to the production of sprays with average drop diameter less than 30fim mass mean diameter depending on the pressure used. The maximum size of the drops formed are a function of the design of the atomiser. In this study, droplet size in a pneumatic atomiser was measured using a laser diffraction technique. The conversion of number count to volume distribution is computed using the Integral Method instead of using the data provided by the measuring device. In addition, the maximum droplet size, X is determined graphically by fitting the data into the Upper Limit Distribution Function, ULDF. Optimisation of fit with ULDF also provided Sauter Mean Diameter, X₃₂ and Volume Mean Diameter, X₃₀ which compare well with the Integral Method of sizing. As a result of this work, drop sizes in pneumatic atomiser can be estimated with great accuracy.
first_indexed 2025-11-14T21:52:54Z
format Article
id uitm-17534
institution Universiti Teknologi MARA
institution_category Local University
language English
last_indexed 2025-11-14T21:52:54Z
publishDate 2007
publisher Faculty of Mechanical Engineering and University Publication Centre (UPENA)
recordtype eprints
repository_type Digital Repository
spelling uitm-175342017-08-01T06:37:30Z https://ir.uitm.edu.my/id/eprint/17534/ Application of ULDF to determine maximum drop size produced by pneumatic atomiser / Fauziah Jerai@Junaidi and Ow Chee Sheng jmeche Pneumatic atomisers are well suited to the production of sprays with average drop diameter less than 30fim mass mean diameter depending on the pressure used. The maximum size of the drops formed are a function of the design of the atomiser. In this study, droplet size in a pneumatic atomiser was measured using a laser diffraction technique. The conversion of number count to volume distribution is computed using the Integral Method instead of using the data provided by the measuring device. In addition, the maximum droplet size, X is determined graphically by fitting the data into the Upper Limit Distribution Function, ULDF. Optimisation of fit with ULDF also provided Sauter Mean Diameter, X₃₂ and Volume Mean Diameter, X₃₀ which compare well with the Integral Method of sizing. As a result of this work, drop sizes in pneumatic atomiser can be estimated with great accuracy. Faculty of Mechanical Engineering and University Publication Centre (UPENA) 2007 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/17534/1/AJ_FAUZIAH%20JERAI%40JUNAIDI%20JME%2007.pdf UNSPECIFIED (2007) Application of ULDF to determine maximum drop size produced by pneumatic atomiser / Fauziah Jerai@Junaidi and Ow Chee Sheng. (2007) Journal of Mechanical Engineering (JMechE) <https://ir.uitm.edu.my/view/publication/Journal_of_Mechanical_Engineering_=28JMechE=29.html>, 4 (1). pp. 1-12. ISSN 1823-5514 ; 2550-164X https://jmeche.uitm.edu.my/
spellingShingle Application of ULDF to determine maximum drop size produced by pneumatic atomiser / Fauziah Jerai@Junaidi and Ow Chee Sheng
title Application of ULDF to determine maximum drop size produced by pneumatic atomiser / Fauziah Jerai@Junaidi and Ow Chee Sheng
title_full Application of ULDF to determine maximum drop size produced by pneumatic atomiser / Fauziah Jerai@Junaidi and Ow Chee Sheng
title_fullStr Application of ULDF to determine maximum drop size produced by pneumatic atomiser / Fauziah Jerai@Junaidi and Ow Chee Sheng
title_full_unstemmed Application of ULDF to determine maximum drop size produced by pneumatic atomiser / Fauziah Jerai@Junaidi and Ow Chee Sheng
title_short Application of ULDF to determine maximum drop size produced by pneumatic atomiser / Fauziah Jerai@Junaidi and Ow Chee Sheng
title_sort application of uldf to determine maximum drop size produced by pneumatic atomiser / fauziah jerai@junaidi and ow chee sheng
url https://ir.uitm.edu.my/id/eprint/17534/
https://ir.uitm.edu.my/id/eprint/17534/