Indoor air quality in enclosed cafeteria at UiTM, Shah Alam / Maizatul Akma Said

Indoor air pollution is consistently reported to be two to five times and occasionally up to 1,000 times higher than outdoor levels. This is alarming considering than the majority of people tent to spend an average of 70% to 96% of their indoor environments. In enclosed cafeteria it has the same sit...

Full description

Bibliographic Details
Main Author: Said, Maizatul Akma
Format: Student Project
Language:English
Published: Faculty of Architecture, Planning and Surveying 2013
Online Access:https://ir.uitm.edu.my/id/eprint/16522/
_version_ 1848804029883219968
author Said, Maizatul Akma
author_facet Said, Maizatul Akma
author_sort Said, Maizatul Akma
building UiTM Institutional Repository
collection Online Access
description Indoor air pollution is consistently reported to be two to five times and occasionally up to 1,000 times higher than outdoor levels. This is alarming considering than the majority of people tent to spend an average of 70% to 96% of their indoor environments. In enclosed cafeteria it has the same situation but not almost users use it and spend an average time in that area. Indoor Air Quality (IAQ), however, is still a relatively unexplored topic in Malaysia. In this study was therefore conducted to examine IAQ from a local perspective. IAQ monitoring was conducted in a selected sample of IAQ in enclosed cafeteria area an impact on human comfort. The three of enclosed cafeteria area were monitored. IAQ parameters measured in this study include temperature; relative humidity and air velocity also have carbon dioxide and carbon monoxide. IAQ measurements were taken in one of the case study were divide into three type of area in that area that is dining area, cooking area and toilet (if have). The overall results shows the IAQ in enclosed cafeteria at UiTM, Shah Alam were not less than the limit of parameters existing IAQ guidelines and standards. However, it still need a good ventilation and air conditioning systems.
first_indexed 2025-11-14T21:48:39Z
format Student Project
id uitm-16522
institution Universiti Teknologi MARA
institution_category Local University
language English
last_indexed 2025-11-14T21:48:39Z
publishDate 2013
publisher Faculty of Architecture, Planning and Surveying
recordtype eprints
repository_type Digital Repository
spelling uitm-165222023-10-23T00:04:59Z https://ir.uitm.edu.my/id/eprint/16522/ Indoor air quality in enclosed cafeteria at UiTM, Shah Alam / Maizatul Akma Said Said, Maizatul Akma Indoor air pollution is consistently reported to be two to five times and occasionally up to 1,000 times higher than outdoor levels. This is alarming considering than the majority of people tent to spend an average of 70% to 96% of their indoor environments. In enclosed cafeteria it has the same situation but not almost users use it and spend an average time in that area. Indoor Air Quality (IAQ), however, is still a relatively unexplored topic in Malaysia. In this study was therefore conducted to examine IAQ from a local perspective. IAQ monitoring was conducted in a selected sample of IAQ in enclosed cafeteria area an impact on human comfort. The three of enclosed cafeteria area were monitored. IAQ parameters measured in this study include temperature; relative humidity and air velocity also have carbon dioxide and carbon monoxide. IAQ measurements were taken in one of the case study were divide into three type of area in that area that is dining area, cooking area and toilet (if have). The overall results shows the IAQ in enclosed cafeteria at UiTM, Shah Alam were not less than the limit of parameters existing IAQ guidelines and standards. However, it still need a good ventilation and air conditioning systems. Faculty of Architecture, Planning and Surveying 2013 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/16522/2/PPb_MAIZATUL%20AKMA%20SAID%20AP%2013_5.pdf Said, Maizatul Akma (2013) Indoor air quality in enclosed cafeteria at UiTM, Shah Alam / Maizatul Akma Said. (2013) [Student Project] <http://terminalib.uitm.edu.my/16522.pdf> (Unpublished)
spellingShingle Said, Maizatul Akma
Indoor air quality in enclosed cafeteria at UiTM, Shah Alam / Maizatul Akma Said
title Indoor air quality in enclosed cafeteria at UiTM, Shah Alam / Maizatul Akma Said
title_full Indoor air quality in enclosed cafeteria at UiTM, Shah Alam / Maizatul Akma Said
title_fullStr Indoor air quality in enclosed cafeteria at UiTM, Shah Alam / Maizatul Akma Said
title_full_unstemmed Indoor air quality in enclosed cafeteria at UiTM, Shah Alam / Maizatul Akma Said
title_short Indoor air quality in enclosed cafeteria at UiTM, Shah Alam / Maizatul Akma Said
title_sort indoor air quality in enclosed cafeteria at uitm, shah alam / maizatul akma said
url https://ir.uitm.edu.my/id/eprint/16522/