Pulse oximeter method as an indicator of blood perfusion in neonate patients / Naszariah Mohd Noor

Blood gas measurements normally provide critical information on oxygenation, ventilation and acid-base status. In critically ill neonates, where peripheral perfusion may drop below the minimums required for tissue oxygenation and cellular respiration, the risk associated with rapid changes in oxy...

Full description

Bibliographic Details
Main Author: Mohd Noor, Naszariah
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/12024/
_version_ 1848803094534553600
author Mohd Noor, Naszariah
author_facet Mohd Noor, Naszariah
author_sort Mohd Noor, Naszariah
building UiTM Institutional Repository
collection Online Access
description Blood gas measurements normally provide critical information on oxygenation, ventilation and acid-base status. In critically ill neonates, where peripheral perfusion may drop below the minimums required for tissue oxygenation and cellular respiration, the risk associated with rapid changes in oxygen saturation is high. Thus, effective means of monitoring blood oxygen saturation is essential. Using pulse oximetry is appealing because it is non-invasive and correlates well with arterial gases. Optimal pulse oximetry monitoring accuracy is depending on the selection of a monitoring site characterized by good perfusion with oxygen saturation. The aim of this research is to investigate the use of pulse oximetry as a non-invasive indicator of blood perfusion of preterm newborns. One hundred and fifty (89 male and 61 female) preterm newborns, regardless of ethnic group and delivery norm, admitted in Special Care Nursery University Malaya Medical Centre were recruited for this observational study from 2006 to 2008. The inclusion criteria were neonates with a diagnosis of respiratory distress syndrome who required ventilatory support, gestational age between 28 weeks to 37 weeks, and weighing less than 2500g. Healthy preterm neonates weighing more than 2500g were excluded. Mathematical modeling was used to model the correlation between the oxygen saturation and blood perfusion. With the analysis made, perfusion index correlates positively with oxygen saturation for both palm and foot sensors (r = 0.91, r = 0.92) respectively with an accuracy of 96%. Hence, pulse oximetry technique is a useful tool to indicate the blood perfusion in neonate patients.
first_indexed 2025-11-14T21:33:47Z
format Thesis
id uitm-12024
institution Universiti Teknologi MARA
institution_category Local University
language English
last_indexed 2025-11-14T21:33:47Z
publishDate 2013
recordtype eprints
repository_type Digital Repository
spelling uitm-120242016-05-14T07:43:43Z https://ir.uitm.edu.my/id/eprint/12024/ Pulse oximeter method as an indicator of blood perfusion in neonate patients / Naszariah Mohd Noor Mohd Noor, Naszariah TK Electrical engineering. Electronics. Nuclear engineering Blood gas measurements normally provide critical information on oxygenation, ventilation and acid-base status. In critically ill neonates, where peripheral perfusion may drop below the minimums required for tissue oxygenation and cellular respiration, the risk associated with rapid changes in oxygen saturation is high. Thus, effective means of monitoring blood oxygen saturation is essential. Using pulse oximetry is appealing because it is non-invasive and correlates well with arterial gases. Optimal pulse oximetry monitoring accuracy is depending on the selection of a monitoring site characterized by good perfusion with oxygen saturation. The aim of this research is to investigate the use of pulse oximetry as a non-invasive indicator of blood perfusion of preterm newborns. One hundred and fifty (89 male and 61 female) preterm newborns, regardless of ethnic group and delivery norm, admitted in Special Care Nursery University Malaya Medical Centre were recruited for this observational study from 2006 to 2008. The inclusion criteria were neonates with a diagnosis of respiratory distress syndrome who required ventilatory support, gestational age between 28 weeks to 37 weeks, and weighing less than 2500g. Healthy preterm neonates weighing more than 2500g were excluded. Mathematical modeling was used to model the correlation between the oxygen saturation and blood perfusion. With the analysis made, perfusion index correlates positively with oxygen saturation for both palm and foot sensors (r = 0.91, r = 0.92) respectively with an accuracy of 96%. Hence, pulse oximetry technique is a useful tool to indicate the blood perfusion in neonate patients. 2013 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/12024/1/TM_NASZARIAH%20MOHD%20NOOR%20EE%2013_5%201.pdf Mohd Noor, Naszariah (2013) Pulse oximeter method as an indicator of blood perfusion in neonate patients / Naszariah Mohd Noor. (2013) Masters thesis, thesis, Universiti Teknologi MARA.
spellingShingle TK Electrical engineering. Electronics. Nuclear engineering
Mohd Noor, Naszariah
Pulse oximeter method as an indicator of blood perfusion in neonate patients / Naszariah Mohd Noor
title Pulse oximeter method as an indicator of blood perfusion in neonate patients / Naszariah Mohd Noor
title_full Pulse oximeter method as an indicator of blood perfusion in neonate patients / Naszariah Mohd Noor
title_fullStr Pulse oximeter method as an indicator of blood perfusion in neonate patients / Naszariah Mohd Noor
title_full_unstemmed Pulse oximeter method as an indicator of blood perfusion in neonate patients / Naszariah Mohd Noor
title_short Pulse oximeter method as an indicator of blood perfusion in neonate patients / Naszariah Mohd Noor
title_sort pulse oximeter method as an indicator of blood perfusion in neonate patients / naszariah mohd noor
topic TK Electrical engineering. Electronics. Nuclear engineering
url https://ir.uitm.edu.my/id/eprint/12024/