Real-time germanium-doped optical fibers for clinical computed tomography dosimetry

In studies focusing on the practice of clinical computed tomography (CT) a particular concern has been that of delivering unnecessary dose to patients and with it the added risk for radiation-induced cancers. For a CT system, present work has investigated the dosimetric characteristics of a Ge-doped...

Full description

Bibliographic Details
Main Authors: Sarhan, H.G., Saini, S.M., Bahari, N.M., Bradley, D.A. *, Zubair, H.T., Basaif, A., Oresegun, A.A., Rashid, H.A. Abdul, Noor, N. M.
Format: Article
Published: Elsevier 2023
Subjects:
Online Access:http://eprints.sunway.edu.my/2277/
_version_ 1848802245537169408
author Sarhan, H.G.
Saini, S.M.
Bahari, N.M.
Bradley, D.A. *
Zubair, H.T.
Basaif, A.
Oresegun, A.A.
Rashid, H.A. Abdul
Noor, N. M.
author_facet Sarhan, H.G.
Saini, S.M.
Bahari, N.M.
Bradley, D.A. *
Zubair, H.T.
Basaif, A.
Oresegun, A.A.
Rashid, H.A. Abdul
Noor, N. M.
author_sort Sarhan, H.G.
building SU Institutional Repository
collection Online Access
description In studies focusing on the practice of clinical computed tomography (CT) a particular concern has been that of delivering unnecessary dose to patients and with it the added risk for radiation-induced cancers. For a CT system, present work has investigated the dosimetric characteristics of a Ge-doped optical fiber real-time dosimetry system (model LS-2000, Lumisyns), measuring beam quality, exposure linearity and exposure duration accuracy. For comparison, the study has used a RaySafe X2 test device (Unfors RaySafe) and a Black Piranha (RTI) QA meter. Irradiations were made using a Somatom Definition Flash dual-source 128-slice CT scanner (Siemens Healthcare). The LS-2000, RaySafe X2, and Black Piranha sensors were exposed to beams energized at accelerating potentials ranging from 80 to 140 kVp, with tube current-time products from 50 to 300 mA, and exposure durations from 750 to 2000 ms. Constant signal responses from the LS-2000 have been obtained, measured in respect of beam quality, exposure linearity, and time accuracy. In respect of accuracy of beam quality, the RaySafe X2 and Black Piranha maximum deviations were 1% and 5%, respectively; the coefficients of linearity of RaySafe, Black Piranha and LS-2000 are 1%, 0.4% and 1.4%, respectively; the maximum deviation for the time accuracy test for the three sensors are 0.5%, 2% and 1.3%, respectively. Evaluation of the LS-2000 real-time dosimetry system with a Ge-doped optical fiber scintillator points to potential for its use in clinical CT dosimetry.
first_indexed 2025-11-14T21:20:17Z
format Article
id sunway-2277
institution Sunway University
institution_category Local University
last_indexed 2025-11-14T21:20:17Z
publishDate 2023
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling sunway-22772023-06-17T12:00:22Z http://eprints.sunway.edu.my/2277/ Real-time germanium-doped optical fibers for clinical computed tomography dosimetry Sarhan, H.G. Saini, S.M. Bahari, N.M. Bradley, D.A. * Zubair, H.T. Basaif, A. Oresegun, A.A. Rashid, H.A. Abdul Noor, N. M. QC Physics RC Internal medicine In studies focusing on the practice of clinical computed tomography (CT) a particular concern has been that of delivering unnecessary dose to patients and with it the added risk for radiation-induced cancers. For a CT system, present work has investigated the dosimetric characteristics of a Ge-doped optical fiber real-time dosimetry system (model LS-2000, Lumisyns), measuring beam quality, exposure linearity and exposure duration accuracy. For comparison, the study has used a RaySafe X2 test device (Unfors RaySafe) and a Black Piranha (RTI) QA meter. Irradiations were made using a Somatom Definition Flash dual-source 128-slice CT scanner (Siemens Healthcare). The LS-2000, RaySafe X2, and Black Piranha sensors were exposed to beams energized at accelerating potentials ranging from 80 to 140 kVp, with tube current-time products from 50 to 300 mA, and exposure durations from 750 to 2000 ms. Constant signal responses from the LS-2000 have been obtained, measured in respect of beam quality, exposure linearity, and time accuracy. In respect of accuracy of beam quality, the RaySafe X2 and Black Piranha maximum deviations were 1% and 5%, respectively; the coefficients of linearity of RaySafe, Black Piranha and LS-2000 are 1%, 0.4% and 1.4%, respectively; the maximum deviation for the time accuracy test for the three sensors are 0.5%, 2% and 1.3%, respectively. Evaluation of the LS-2000 real-time dosimetry system with a Ge-doped optical fiber scintillator points to potential for its use in clinical CT dosimetry. Elsevier 2023-08 Article PeerReviewed Sarhan, H.G. and Saini, S.M. and Bahari, N.M. and Bradley, D.A. * and Zubair, H.T. and Basaif, A. and Oresegun, A.A. and Rashid, H.A. Abdul and Noor, N. M. (2023) Real-time germanium-doped optical fibers for clinical computed tomography dosimetry. Radiation Physics and Chemistry, 209. ISSN 0969-806X https://doi.org/10.1016/j.radphyschem.2023.110972 10.1016/j.radphyschem.2023.110972
spellingShingle QC Physics
RC Internal medicine
Sarhan, H.G.
Saini, S.M.
Bahari, N.M.
Bradley, D.A. *
Zubair, H.T.
Basaif, A.
Oresegun, A.A.
Rashid, H.A. Abdul
Noor, N. M.
Real-time germanium-doped optical fibers for clinical computed tomography dosimetry
title Real-time germanium-doped optical fibers for clinical computed tomography dosimetry
title_full Real-time germanium-doped optical fibers for clinical computed tomography dosimetry
title_fullStr Real-time germanium-doped optical fibers for clinical computed tomography dosimetry
title_full_unstemmed Real-time germanium-doped optical fibers for clinical computed tomography dosimetry
title_short Real-time germanium-doped optical fibers for clinical computed tomography dosimetry
title_sort real-time germanium-doped optical fibers for clinical computed tomography dosimetry
topic QC Physics
RC Internal medicine
url http://eprints.sunway.edu.my/2277/
http://eprints.sunway.edu.my/2277/
http://eprints.sunway.edu.my/2277/