Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method

Computed tomography (CT) derived Monte Carlo (MC) phantoms allow dose determination within small animal models that is not feasible with in-vivo dosimetry. The aim of this study was to develop a CT-derived MC phantom generated from a mouse with a xenograft tumour that could then be used to calculate...

Full description

Bibliographic Details
Main Authors: Entezam, Amir, Fielding, Andrew, Bradley, D.A. *, Fontanarosa, Davide
Format: Article
Language:English
Published: PLOS 2023
Subjects:
Online Access:http://eprints.sunway.edu.my/2254/
http://eprints.sunway.edu.my/2254/1/32.pdf
_version_ 1848802238918557696
author Entezam, Amir
Fielding, Andrew
Bradley, D.A. *
Fontanarosa, Davide
author_facet Entezam, Amir
Fielding, Andrew
Bradley, D.A. *
Fontanarosa, Davide
author_sort Entezam, Amir
building SU Institutional Repository
collection Online Access
description Computed tomography (CT) derived Monte Carlo (MC) phantoms allow dose determination within small animal models that is not feasible with in-vivo dosimetry. The aim of this study was to develop a CT-derived MC phantom generated from a mouse with a xenograft tumour that could then be used to calculate both the dose heterogeneity in the tumour volume and out of field scattered dose for pre-clinical small animal irradiation experiments. A BEAMnrc Monte-Carlo model has been built of our irradiation system that comprises a lead collimator with a 1 cm diameter aperture fitted to a Cs-137 gamma irradiator. The MC model of the irradiation system was validated by comparing the calculated dose results with dosimetric film measurement in a polymethyl methacrylate (PMMA) phantom using a 1D gamma-index analysis. Dose distributions in the MC mouse phantom were calculated and visualized on the CT-image data. Dose volume histograms (DVHs) were generated for the tumour and organs at risk (OARs). The effect of the xenographic tumour volume on the scattered out of field dose was also investigated. The defined gamma index analysis criteria were met, indicating that our MC simulation is a valid model for MC mouse phantom dose calculations. MC dose calculations showed a maximum out of field dose to the mouse of 7% of Dmax. Absorbed dose to the tumour varies in the range 60%-100% of Dmax. DVH analysis demonstrated that tumour received an inhomogeneous dose of 12 Gy-20 Gy (for 20 Gy prescribed dose) while out of field doses to all OARs were minimized (1.29 Gy-1.38 Gy). Variation of the xenographic tumour volume exhibited no significant effect on the out of field scattered dose to OARs. The CT derived MC mouse model presented here is a useful tool for tumour dose verifications as well as investigating the doses to normal tissue (in out of field) for preclinical radiobiological research.
first_indexed 2025-11-14T21:20:11Z
format Article
id sunway-2254
institution Sunway University
institution_category Local University
language English
last_indexed 2025-11-14T21:20:11Z
publishDate 2023
publisher PLOS
recordtype eprints
repository_type Digital Repository
spelling sunway-22542023-06-16T03:13:39Z http://eprints.sunway.edu.my/2254/ Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method Entezam, Amir Fielding, Andrew Bradley, D.A. * Fontanarosa, Davide QA Mathematics RC Internal medicine Computed tomography (CT) derived Monte Carlo (MC) phantoms allow dose determination within small animal models that is not feasible with in-vivo dosimetry. The aim of this study was to develop a CT-derived MC phantom generated from a mouse with a xenograft tumour that could then be used to calculate both the dose heterogeneity in the tumour volume and out of field scattered dose for pre-clinical small animal irradiation experiments. A BEAMnrc Monte-Carlo model has been built of our irradiation system that comprises a lead collimator with a 1 cm diameter aperture fitted to a Cs-137 gamma irradiator. The MC model of the irradiation system was validated by comparing the calculated dose results with dosimetric film measurement in a polymethyl methacrylate (PMMA) phantom using a 1D gamma-index analysis. Dose distributions in the MC mouse phantom were calculated and visualized on the CT-image data. Dose volume histograms (DVHs) were generated for the tumour and organs at risk (OARs). The effect of the xenographic tumour volume on the scattered out of field dose was also investigated. The defined gamma index analysis criteria were met, indicating that our MC simulation is a valid model for MC mouse phantom dose calculations. MC dose calculations showed a maximum out of field dose to the mouse of 7% of Dmax. Absorbed dose to the tumour varies in the range 60%-100% of Dmax. DVH analysis demonstrated that tumour received an inhomogeneous dose of 12 Gy-20 Gy (for 20 Gy prescribed dose) while out of field doses to all OARs were minimized (1.29 Gy-1.38 Gy). Variation of the xenographic tumour volume exhibited no significant effect on the out of field scattered dose to OARs. The CT derived MC mouse model presented here is a useful tool for tumour dose verifications as well as investigating the doses to normal tissue (in out of field) for preclinical radiobiological research. PLOS 2023-02-02 Article PeerReviewed text en cc_by_4 http://eprints.sunway.edu.my/2254/1/32.pdf Entezam, Amir and Fielding, Andrew and Bradley, D.A. * and Fontanarosa, Davide (2023) Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method. PLOS ONE, 18 (2). ISSN 1932-6203 https://doi.org/10.1371/journal.pone.0280765 10.1371/journal.pone.0280765
spellingShingle QA Mathematics
RC Internal medicine
Entezam, Amir
Fielding, Andrew
Bradley, D.A. *
Fontanarosa, Davide
Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method
title Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method
title_full Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method
title_fullStr Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method
title_full_unstemmed Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method
title_short Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method
title_sort absorbed dose calculation for a realistic ct-derived mouse phantom irradiated with a standard cs-137 cell irradiator using a monte carlo method
topic QA Mathematics
RC Internal medicine
url http://eprints.sunway.edu.my/2254/
http://eprints.sunway.edu.my/2254/
http://eprints.sunway.edu.my/2254/
http://eprints.sunway.edu.my/2254/1/32.pdf