Dosimetric evaluation of gold nanoparticle aided intraoperative radiotherapy with the Intrabeam system using Monte Carlo simulations

Radiosensitization using high atomic number nanoparticles (NPs) has been shown to be an effective method to enhance radiotherapy efficiency. The pathways by which NPs cause sensitization, are generally categorized as physical, chemical and biological effects. Specifically in the case of keV photon r...

Full description

Bibliographic Details
Main Authors: Moradi, F., Abdul Sani, S.F., Khandaker, Mayeen Uddin *, Sulieman, A., Bradley, D.A. *
Format: Article
Published: Elsevier 2021
Subjects:
Online Access:http://eprints.sunway.edu.my/1595/
_version_ 1848802095965143040
author Moradi, F.
Abdul Sani, S.F.
Khandaker, Mayeen Uddin *
Sulieman, A.
Bradley, D.A. *
author_facet Moradi, F.
Abdul Sani, S.F.
Khandaker, Mayeen Uddin *
Sulieman, A.
Bradley, D.A. *
author_sort Moradi, F.
building SU Institutional Repository
collection Online Access
description Radiosensitization using high atomic number nanoparticles (NPs) has been shown to be an effective method to enhance radiotherapy efficiency. The pathways by which NPs cause sensitization, are generally categorized as physical, chemical and biological effects. Specifically in the case of keV photon radiotherapy where the contribution of physical effects in radiosensitization mechanism is considerable, Monte Carlo (MC) simulations have been an efficient tool to predict the radioenhancement level and to calculate dose enhancement factor (DEF). To-date, several analytical, simulational and experimental studies have reported the radiosensitization effect of gold nanoparticles (GNPs) in various brachytherapy situations. In this work we report for the first time, the DEFs achievable in intraoperative radiotherapy through use of the Intrabeam system and its spherical applicators with addition of GNPs. The MCNPX Monte Carlo code was used for radiation transport and dose calculations. The results of macroscopic and microscopic analysis show that for the Intrabeam system and a homogeneous distribution of 50 nm diameter GNPs, respective DEFs of up to some 1.5, 2, 2.5 and 3 in the tumour bed can be achieved with 5, 10, 15 and 20 mg/g concentrations. Due to rapid change in electron spectra, DEFs greater than 1 mm separation from the applicator surface decrease with distance, offering an additional advantage.
first_indexed 2025-11-14T21:17:54Z
format Article
id sunway-1595
institution Sunway University
institution_category Local University
last_indexed 2025-11-14T21:17:54Z
publishDate 2021
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling sunway-15952021-02-11T08:17:58Z http://eprints.sunway.edu.my/1595/ Dosimetric evaluation of gold nanoparticle aided intraoperative radiotherapy with the Intrabeam system using Monte Carlo simulations Moradi, F. Abdul Sani, S.F. Khandaker, Mayeen Uddin * Sulieman, A. Bradley, D.A. * R895-920 Medical Physics/Medical Radiology Radiosensitization using high atomic number nanoparticles (NPs) has been shown to be an effective method to enhance radiotherapy efficiency. The pathways by which NPs cause sensitization, are generally categorized as physical, chemical and biological effects. Specifically in the case of keV photon radiotherapy where the contribution of physical effects in radiosensitization mechanism is considerable, Monte Carlo (MC) simulations have been an efficient tool to predict the radioenhancement level and to calculate dose enhancement factor (DEF). To-date, several analytical, simulational and experimental studies have reported the radiosensitization effect of gold nanoparticles (GNPs) in various brachytherapy situations. In this work we report for the first time, the DEFs achievable in intraoperative radiotherapy through use of the Intrabeam system and its spherical applicators with addition of GNPs. The MCNPX Monte Carlo code was used for radiation transport and dose calculations. The results of macroscopic and microscopic analysis show that for the Intrabeam system and a homogeneous distribution of 50 nm diameter GNPs, respective DEFs of up to some 1.5, 2, 2.5 and 3 in the tumour bed can be achieved with 5, 10, 15 and 20 mg/g concentrations. Due to rapid change in electron spectra, DEFs greater than 1 mm separation from the applicator surface decrease with distance, offering an additional advantage. Elsevier 2021-01 Article PeerReviewed Moradi, F. and Abdul Sani, S.F. and Khandaker, Mayeen Uddin * and Sulieman, A. and Bradley, D.A. * (2021) Dosimetric evaluation of gold nanoparticle aided intraoperative radiotherapy with the Intrabeam system using Monte Carlo simulations. Radiation Physics and Chemistry, 178. p. 108864. ISSN 0969-806X http://doi.org/10.1016/j.radphyschem.2020.108864 doi:10.1016/j.radphyschem.2020.108864
spellingShingle R895-920 Medical Physics/Medical Radiology
Moradi, F.
Abdul Sani, S.F.
Khandaker, Mayeen Uddin *
Sulieman, A.
Bradley, D.A. *
Dosimetric evaluation of gold nanoparticle aided intraoperative radiotherapy with the Intrabeam system using Monte Carlo simulations
title Dosimetric evaluation of gold nanoparticle aided intraoperative radiotherapy with the Intrabeam system using Monte Carlo simulations
title_full Dosimetric evaluation of gold nanoparticle aided intraoperative radiotherapy with the Intrabeam system using Monte Carlo simulations
title_fullStr Dosimetric evaluation of gold nanoparticle aided intraoperative radiotherapy with the Intrabeam system using Monte Carlo simulations
title_full_unstemmed Dosimetric evaluation of gold nanoparticle aided intraoperative radiotherapy with the Intrabeam system using Monte Carlo simulations
title_short Dosimetric evaluation of gold nanoparticle aided intraoperative radiotherapy with the Intrabeam system using Monte Carlo simulations
title_sort dosimetric evaluation of gold nanoparticle aided intraoperative radiotherapy with the intrabeam system using monte carlo simulations
topic R895-920 Medical Physics/Medical Radiology
url http://eprints.sunway.edu.my/1595/
http://eprints.sunway.edu.my/1595/
http://eprints.sunway.edu.my/1595/