Passive dosimetry of electron irradiated borosilicate glass slides

Thermoluminescence dosimetry most typically concerns the sensing and quantification of ionizing radiation exposures, with evaluation of absorbed dose arising from electron-hole trapping in well-disposed insulating/semi-conducting media. In this passive form of dosimetry the signal derives from photo...

Full description

Bibliographic Details
Main Authors: Sani, S.F. A., Othman, M.H.U., Alqahtani, A., Nazeri, A.A.Z. A., Almugren, K.S., Ung, N.M., Hashim, S.A., Alkallas, F.H., Bradley, D.A. *
Format: Article
Published: Elsevier 2021
Subjects:
Online Access:http://eprints.sunway.edu.my/1594/
_version_ 1848802095717679104
author Sani, S.F. A.
Othman, M.H.U.
Alqahtani, A.
Nazeri, A.A.Z. A.
Almugren, K.S.
Ung, N.M.
Hashim, S.A.
Alkallas, F.H.
Bradley, D.A. *
author_facet Sani, S.F. A.
Othman, M.H.U.
Alqahtani, A.
Nazeri, A.A.Z. A.
Almugren, K.S.
Ung, N.M.
Hashim, S.A.
Alkallas, F.H.
Bradley, D.A. *
author_sort Sani, S.F. A.
building SU Institutional Repository
collection Online Access
description Thermoluminescence dosimetry most typically concerns the sensing and quantification of ionizing radiation exposures, with evaluation of absorbed dose arising from electron-hole trapping in well-disposed insulating/semi-conducting media. In this passive form of dosimetry the signal derives from photons released post-irradiation heating of the dosimeter over a specific temperature range. Herein, for entrance doses from 2 Gy up to 250 kGy, investigation is made of the thermoluminescence properties of electron irradiated borosilicate glass (SiO2–B2O3), the samples deriving from commercial microscope slides (coverslips) of thickness 1.0 mm. The coverslips provide linear TL response over a wide range of radiation dose, through use of a clinical linear accelerator in a lower dose regime (2–10 Gy) and use of a product-irradiation electron linac in a higher dose regime (25 kGy–250 kGy), obtaining a regression coefficient in excess of 96%. In the high dose regime comparison has been made with the response of Ge–B doped Flat Fibre (FF) and Ge–B doped photonic crystal fibre (PCF) (collapsed). Deconvolution shows the glow curves of the borosilicate glass to be formed of five overlapping peaks, with figures of merit (FOM) of between 0.62 – 1.72 and 0.87–1.00 for the particular dose ranges 2–10 Gy and 25 kGy–250 kGy respectively. Through use of Glowfit deconvolution software, the key trapping parameters of activation energy and frequency factor were calculated for the borosilicate glass slide.
first_indexed 2025-11-14T21:17:54Z
format Article
id sunway-1594
institution Sunway University
institution_category Local University
last_indexed 2025-11-14T21:17:54Z
publishDate 2021
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling sunway-15942021-02-15T04:53:08Z http://eprints.sunway.edu.my/1594/ Passive dosimetry of electron irradiated borosilicate glass slides Sani, S.F. A. Othman, M.H.U. Alqahtani, A. Nazeri, A.A.Z. A. Almugren, K.S. Ung, N.M. Hashim, S.A. Alkallas, F.H. Bradley, D.A. * R895-920 Medical Physics/Medical Radiology Thermoluminescence dosimetry most typically concerns the sensing and quantification of ionizing radiation exposures, with evaluation of absorbed dose arising from electron-hole trapping in well-disposed insulating/semi-conducting media. In this passive form of dosimetry the signal derives from photons released post-irradiation heating of the dosimeter over a specific temperature range. Herein, for entrance doses from 2 Gy up to 250 kGy, investigation is made of the thermoluminescence properties of electron irradiated borosilicate glass (SiO2–B2O3), the samples deriving from commercial microscope slides (coverslips) of thickness 1.0 mm. The coverslips provide linear TL response over a wide range of radiation dose, through use of a clinical linear accelerator in a lower dose regime (2–10 Gy) and use of a product-irradiation electron linac in a higher dose regime (25 kGy–250 kGy), obtaining a regression coefficient in excess of 96%. In the high dose regime comparison has been made with the response of Ge–B doped Flat Fibre (FF) and Ge–B doped photonic crystal fibre (PCF) (collapsed). Deconvolution shows the glow curves of the borosilicate glass to be formed of five overlapping peaks, with figures of merit (FOM) of between 0.62 – 1.72 and 0.87–1.00 for the particular dose ranges 2–10 Gy and 25 kGy–250 kGy respectively. Through use of Glowfit deconvolution software, the key trapping parameters of activation energy and frequency factor were calculated for the borosilicate glass slide. Elsevier 2021-01 Article PeerReviewed Sani, S.F. A. and Othman, M.H.U. and Alqahtani, A. and Nazeri, A.A.Z. A. and Almugren, K.S. and Ung, N.M. and Hashim, S.A. and Alkallas, F.H. and Bradley, D.A. * (2021) Passive dosimetry of electron irradiated borosilicate glass slides. Radiation Physics and Chemistry, 178. p. 108903. ISSN 0969-806X http://doi.org/10.1016/j.radphyschem.2020.108903 doi:10.1016/j.radphyschem.2020.108903
spellingShingle R895-920 Medical Physics/Medical Radiology
Sani, S.F. A.
Othman, M.H.U.
Alqahtani, A.
Nazeri, A.A.Z. A.
Almugren, K.S.
Ung, N.M.
Hashim, S.A.
Alkallas, F.H.
Bradley, D.A. *
Passive dosimetry of electron irradiated borosilicate glass slides
title Passive dosimetry of electron irradiated borosilicate glass slides
title_full Passive dosimetry of electron irradiated borosilicate glass slides
title_fullStr Passive dosimetry of electron irradiated borosilicate glass slides
title_full_unstemmed Passive dosimetry of electron irradiated borosilicate glass slides
title_short Passive dosimetry of electron irradiated borosilicate glass slides
title_sort passive dosimetry of electron irradiated borosilicate glass slides
topic R895-920 Medical Physics/Medical Radiology
url http://eprints.sunway.edu.my/1594/
http://eprints.sunway.edu.my/1594/
http://eprints.sunway.edu.my/1594/