Current Sudan protective practice in diagnostic nuclear medicine and patient dose

Reflecting upon the influence of current diagnostic imaging radiation protection practices in Sudan, a sampling evaluation is made of administered activity across all five of the nuclear medicine departments in the country. Data were collected in respect of 423 patients, administered nuclide activit...

Full description

Bibliographic Details
Main Authors: Edam, A.N., Sulieman, A., Tamam, N., Abuelhaia, E., Salih, I., Sam, A.K., Yousef, M., Alkhorayef, M., Bradley, D.A. *
Format: Article
Published: Elsevier 2021
Subjects:
Online Access:http://eprints.sunway.edu.my/1575/
_version_ 1848802090638376960
author Edam, A.N.
Sulieman, A.
Tamam, N.
Abuelhaia, E.
Salih, I.
Sam, A.K.
Yousef, M.
Alkhorayef, M.
Bradley, D.A. *
author_facet Edam, A.N.
Sulieman, A.
Tamam, N.
Abuelhaia, E.
Salih, I.
Sam, A.K.
Yousef, M.
Alkhorayef, M.
Bradley, D.A. *
author_sort Edam, A.N.
building SU Institutional Repository
collection Online Access
description Reflecting upon the influence of current diagnostic imaging radiation protection practices in Sudan, a sampling evaluation is made of administered activity across all five of the nuclear medicine departments in the country. Data were collected in respect of 423 patients, administered nuclide activities showing accord with international levels. For administered activity, four of the five departments use International Atomic Energy Agency (IAEA) Basic Safety Standard protocols, the other adopting UK Administration of Radioactive Substances Advisory Committee (ARSAC) practice. For national nuclear medicine diagnostic purposes overwhelming use is made of 99mTc. Thyroid and parathyroid scans account for 43% of the 423 investigations, while whole body bone and renal scans provide for the imaging needs of the respective 34% and 23% remaining patients. Of the acquired images, in excess of 80% of these were planar. The mean and standard deviation effective dose values were 2.26 ± 0.61, 4.70 ± 0.77 and 1.03 ± 0.29 mSv, for thyroid, bone and dynamic renal scans respectively, comparable with that of previous studies. While department designs are observed to comply with radiation protection regulations, the personal monitoring service is much less satisfactory, data frequently being found to be absent in all five departments. Moreover, only 60% of the medical physicists have been in receipt of regular radiation protection training, while other medical staff within the departments have not benefited from the relevant training at all, including physicians, nurses and nuclear medicine technologists. None have received regular specific medical checks. Accordingly, the Sudanese Nuclear & Radiological Regulatory Authority are now playing a major role in development of nuclear medicine practice and associated safety requirements, seeking accord with the principle of ALARA. Physician/medical physicist cooperation is needed in addressing optimization of radiation dose and image quality, also radiation protection awareness and training, as well as in medical surveillance.
first_indexed 2025-11-14T21:17:49Z
format Article
id sunway-1575
institution Sunway University
institution_category Local University
last_indexed 2025-11-14T21:17:49Z
publishDate 2021
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling sunway-15752021-02-11T08:24:05Z http://eprints.sunway.edu.my/1575/ Current Sudan protective practice in diagnostic nuclear medicine and patient dose Edam, A.N. Sulieman, A. Tamam, N. Abuelhaia, E. Salih, I. Sam, A.K. Yousef, M. Alkhorayef, M. Bradley, D.A. * R895-920 Medical Physics/Medical Radiology Reflecting upon the influence of current diagnostic imaging radiation protection practices in Sudan, a sampling evaluation is made of administered activity across all five of the nuclear medicine departments in the country. Data were collected in respect of 423 patients, administered nuclide activities showing accord with international levels. For administered activity, four of the five departments use International Atomic Energy Agency (IAEA) Basic Safety Standard protocols, the other adopting UK Administration of Radioactive Substances Advisory Committee (ARSAC) practice. For national nuclear medicine diagnostic purposes overwhelming use is made of 99mTc. Thyroid and parathyroid scans account for 43% of the 423 investigations, while whole body bone and renal scans provide for the imaging needs of the respective 34% and 23% remaining patients. Of the acquired images, in excess of 80% of these were planar. The mean and standard deviation effective dose values were 2.26 ± 0.61, 4.70 ± 0.77 and 1.03 ± 0.29 mSv, for thyroid, bone and dynamic renal scans respectively, comparable with that of previous studies. While department designs are observed to comply with radiation protection regulations, the personal monitoring service is much less satisfactory, data frequently being found to be absent in all five departments. Moreover, only 60% of the medical physicists have been in receipt of regular radiation protection training, while other medical staff within the departments have not benefited from the relevant training at all, including physicians, nurses and nuclear medicine technologists. None have received regular specific medical checks. Accordingly, the Sudanese Nuclear & Radiological Regulatory Authority are now playing a major role in development of nuclear medicine practice and associated safety requirements, seeking accord with the principle of ALARA. Physician/medical physicist cooperation is needed in addressing optimization of radiation dose and image quality, also radiation protection awareness and training, as well as in medical surveillance. Elsevier 2021-05 Article PeerReviewed Edam, A.N. and Sulieman, A. and Tamam, N. and Abuelhaia, E. and Salih, I. and Sam, A.K. and Yousef, M. and Alkhorayef, M. and Bradley, D.A. * (2021) Current Sudan protective practice in diagnostic nuclear medicine and patient dose. Radiation Physics and Chemistry, 178. p. 108997. ISSN 0969-806X http://doi.org/10.1016/j.radphyschem.2020.108997 doi:10.1016/j.radphyschem.2020.108997
spellingShingle R895-920 Medical Physics/Medical Radiology
Edam, A.N.
Sulieman, A.
Tamam, N.
Abuelhaia, E.
Salih, I.
Sam, A.K.
Yousef, M.
Alkhorayef, M.
Bradley, D.A. *
Current Sudan protective practice in diagnostic nuclear medicine and patient dose
title Current Sudan protective practice in diagnostic nuclear medicine and patient dose
title_full Current Sudan protective practice in diagnostic nuclear medicine and patient dose
title_fullStr Current Sudan protective practice in diagnostic nuclear medicine and patient dose
title_full_unstemmed Current Sudan protective practice in diagnostic nuclear medicine and patient dose
title_short Current Sudan protective practice in diagnostic nuclear medicine and patient dose
title_sort current sudan protective practice in diagnostic nuclear medicine and patient dose
topic R895-920 Medical Physics/Medical Radiology
url http://eprints.sunway.edu.my/1575/
http://eprints.sunway.edu.my/1575/
http://eprints.sunway.edu.my/1575/