Comparison between PRIMO and EGSnrc Monte Carlo models of the Varian True Beam linear accelerator

The study objectives were to simulate a 6 MV flattening filter-free (FFF) photon beam of a TrueBeam Varian LINAC, using the PRIMO code. The depth-dose profiles for various jaw open fields and cross-beam profiles for various depths inside water phantoms were determined using PRIMO simulations and wer...

Full description

Bibliographic Details
Main Authors: Aamri, Hussin, Fielding, Andrew, Aamry, Ali, Sulieman, Abdelmoneim, Tamam, Nissren, Alkhorayef, Mohammed, Bradley, D.A. *
Format: Article
Published: Elsevier 2021
Subjects:
Online Access:http://eprints.sunway.edu.my/1572/
_version_ 1848802089717727232
author Aamri, Hussin
Fielding, Andrew
Aamry, Ali
Sulieman, Abdelmoneim
Tamam, Nissren
Alkhorayef, Mohammed
Bradley, D.A. *
author_facet Aamri, Hussin
Fielding, Andrew
Aamry, Ali
Sulieman, Abdelmoneim
Tamam, Nissren
Alkhorayef, Mohammed
Bradley, D.A. *
author_sort Aamri, Hussin
building SU Institutional Repository
collection Online Access
description The study objectives were to simulate a 6 MV flattening filter-free (FFF) photon beam of a TrueBeam Varian LINAC, using the PRIMO code. The depth-dose profiles for various jaw open fields and cross-beam profiles for various depths inside water phantoms were determined using PRIMO simulations and were compared with the EGSnrc simulation results. A 93% match between both codes has generally been obtained, with a systematic variation in agreement between the two models that increases with field size. The closest agreement, to within 94%, was obtained for a 6 × 6 cm2 jaw open field at 5.0 cm and 10.0 cm depths, better at 10- than at 5.0 cm depth. The effects of how scatter is modelled has been shown to result in the differences.
first_indexed 2025-11-14T21:17:49Z
format Article
id sunway-1572
institution Sunway University
institution_category Local University
last_indexed 2025-11-14T21:17:49Z
publishDate 2021
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling sunway-15722021-11-02T02:03:30Z http://eprints.sunway.edu.my/1572/ Comparison between PRIMO and EGSnrc Monte Carlo models of the Varian True Beam linear accelerator Aamri, Hussin Fielding, Andrew Aamry, Ali Sulieman, Abdelmoneim Tamam, Nissren Alkhorayef, Mohammed Bradley, D.A. * R895-920 Medical Physics/Medical Radiology The study objectives were to simulate a 6 MV flattening filter-free (FFF) photon beam of a TrueBeam Varian LINAC, using the PRIMO code. The depth-dose profiles for various jaw open fields and cross-beam profiles for various depths inside water phantoms were determined using PRIMO simulations and were compared with the EGSnrc simulation results. A 93% match between both codes has generally been obtained, with a systematic variation in agreement between the two models that increases with field size. The closest agreement, to within 94%, was obtained for a 6 × 6 cm2 jaw open field at 5.0 cm and 10.0 cm depths, better at 10- than at 5.0 cm depth. The effects of how scatter is modelled has been shown to result in the differences. Elsevier 2021-06-12 Article PeerReviewed Aamri, Hussin and Fielding, Andrew and Aamry, Ali and Sulieman, Abdelmoneim and Tamam, Nissren and Alkhorayef, Mohammed and Bradley, D.A. * (2021) Comparison between PRIMO and EGSnrc Monte Carlo models of the Varian True Beam linear accelerator. Radiation Physics and Chemistry, 178. p. 109013. ISSN 0969-806X http://doi.org/10.1016/j.radphyschem.2020.109013 doi:10.1016/j.radphyschem.2020.109013
spellingShingle R895-920 Medical Physics/Medical Radiology
Aamri, Hussin
Fielding, Andrew
Aamry, Ali
Sulieman, Abdelmoneim
Tamam, Nissren
Alkhorayef, Mohammed
Bradley, D.A. *
Comparison between PRIMO and EGSnrc Monte Carlo models of the Varian True Beam linear accelerator
title Comparison between PRIMO and EGSnrc Monte Carlo models of the Varian True Beam linear accelerator
title_full Comparison between PRIMO and EGSnrc Monte Carlo models of the Varian True Beam linear accelerator
title_fullStr Comparison between PRIMO and EGSnrc Monte Carlo models of the Varian True Beam linear accelerator
title_full_unstemmed Comparison between PRIMO and EGSnrc Monte Carlo models of the Varian True Beam linear accelerator
title_short Comparison between PRIMO and EGSnrc Monte Carlo models of the Varian True Beam linear accelerator
title_sort comparison between primo and egsnrc monte carlo models of the varian true beam linear accelerator
topic R895-920 Medical Physics/Medical Radiology
url http://eprints.sunway.edu.my/1572/
http://eprints.sunway.edu.my/1572/
http://eprints.sunway.edu.my/1572/