STRENGTH OF INTERMEDIATE LENGTH TUBULAR STEEL COLUMNS – BARE, CONCRETE FILLED, RETROFITTED OR REHABILITATED

Steel tubular members are used in high rise buildings, industrial structures, piles, bridge piers and offshore structures. The strength of short length steel tubular – bare or infilled with normal concrete – is widely reported. The codes provide expressions for evaluating the nominal strength of sh...

Full description

Bibliographic Details
Main Authors: Narayanan,, S.P, Kalaikumar, V., Cossa , N.J, Hasifi, M.S.
Format: Conference or Workshop Item
Language:English
Published: 2010
Subjects:
Online Access:http://scholars.utp.edu.my/id/eprint/3094/
http://scholars.utp.edu.my/id/eprint/3094/1/WEC-CBIT015.pdf
_version_ 1848659350798729216
author Narayanan,, S.P
Kalaikumar, V.
Cossa , N.J
Hasifi, M.S.
author_facet Narayanan,, S.P
Kalaikumar, V.
Cossa , N.J
Hasifi, M.S.
author_sort Narayanan,, S.P
building UTP Institutional Repository
collection Online Access
description Steel tubular members are used in high rise buildings, industrial structures, piles, bridge piers and offshore structures. The strength of short length steel tubular – bare or infilled with normal concrete – is widely reported. The codes provide expressions for evaluating the nominal strength of short and long, bare and infilled steel columns. Not many studies on intermediate length steel columns are reported. The ongoing research on concrete infilled steel tubular sections has the following aspects: (1) Steel tubulars of length 1200 mm infilled with concrete of grades 30, 60 and 80 N/mm2 tested in axial compression and comparison with the code predicted ultimate strengths using EC4, BS5400, ACI, AS and AIJ. The results show that BS5400 predicted values were 30% lower than experimental results whereas ACI, AS and AIJ predictions were 5% higher for concrete 60Mpa and 80 MPa. (2) Rehabilitation of artificially damaged tubulars using concrete, grout and CFRP sheets. The “artificial damage” simulating typical patch corrosion reduced the ultimate strength by 5-23%. Concrete filled tubulars when corroded had reduced strength by 40-50%. The several retrofit methods showed significant increase in strength. However, grout infill showed highest strength gain, followed by concrete infill. CFRP retrofit showed only limited increase.
first_indexed 2025-11-13T07:29:02Z
format Conference or Workshop Item
id oai:scholars.utp.edu.my:3094
institution Universiti Teknologi Petronas
institution_category Local University
language English
last_indexed 2025-11-13T07:29:02Z
publishDate 2010
recordtype eprints
repository_type Digital Repository
spelling oai:scholars.utp.edu.my:30942017-01-19T08:23:53Z http://scholars.utp.edu.my/id/eprint/3094/ STRENGTH OF INTERMEDIATE LENGTH TUBULAR STEEL COLUMNS – BARE, CONCRETE FILLED, RETROFITTED OR REHABILITATED Narayanan,, S.P Kalaikumar, V. Cossa , N.J Hasifi, M.S. TA Engineering (General). Civil engineering (General) Steel tubular members are used in high rise buildings, industrial structures, piles, bridge piers and offshore structures. The strength of short length steel tubular – bare or infilled with normal concrete – is widely reported. The codes provide expressions for evaluating the nominal strength of short and long, bare and infilled steel columns. Not many studies on intermediate length steel columns are reported. The ongoing research on concrete infilled steel tubular sections has the following aspects: (1) Steel tubulars of length 1200 mm infilled with concrete of grades 30, 60 and 80 N/mm2 tested in axial compression and comparison with the code predicted ultimate strengths using EC4, BS5400, ACI, AS and AIJ. The results show that BS5400 predicted values were 30% lower than experimental results whereas ACI, AS and AIJ predictions were 5% higher for concrete 60Mpa and 80 MPa. (2) Rehabilitation of artificially damaged tubulars using concrete, grout and CFRP sheets. The “artificial damage” simulating typical patch corrosion reduced the ultimate strength by 5-23%. Concrete filled tubulars when corroded had reduced strength by 40-50%. The several retrofit methods showed significant increase in strength. However, grout infill showed highest strength gain, followed by concrete infill. CFRP retrofit showed only limited increase. 2010-08 Conference or Workshop Item PeerReviewed application/pdf en http://scholars.utp.edu.my/id/eprint/3094/1/WEC-CBIT015.pdf Narayanan,, S.P and Kalaikumar, V. and Cossa , N.J and Hasifi, M.S. (2010) STRENGTH OF INTERMEDIATE LENGTH TUBULAR STEEL COLUMNS – BARE, CONCRETE FILLED, RETROFITTED OR REHABILITATED. In: World Engineering Congress 2010, 2-5 August 2010, Kuching. Sarawak.
spellingShingle TA Engineering (General). Civil engineering (General)
Narayanan,, S.P
Kalaikumar, V.
Cossa , N.J
Hasifi, M.S.
STRENGTH OF INTERMEDIATE LENGTH TUBULAR STEEL COLUMNS – BARE, CONCRETE FILLED, RETROFITTED OR REHABILITATED
title STRENGTH OF INTERMEDIATE LENGTH TUBULAR STEEL COLUMNS – BARE, CONCRETE FILLED, RETROFITTED OR REHABILITATED
title_full STRENGTH OF INTERMEDIATE LENGTH TUBULAR STEEL COLUMNS – BARE, CONCRETE FILLED, RETROFITTED OR REHABILITATED
title_fullStr STRENGTH OF INTERMEDIATE LENGTH TUBULAR STEEL COLUMNS – BARE, CONCRETE FILLED, RETROFITTED OR REHABILITATED
title_full_unstemmed STRENGTH OF INTERMEDIATE LENGTH TUBULAR STEEL COLUMNS – BARE, CONCRETE FILLED, RETROFITTED OR REHABILITATED
title_short STRENGTH OF INTERMEDIATE LENGTH TUBULAR STEEL COLUMNS – BARE, CONCRETE FILLED, RETROFITTED OR REHABILITATED
title_sort strength of intermediate length tubular steel columns – bare, concrete filled, retrofitted or rehabilitated
topic TA Engineering (General). Civil engineering (General)
url http://scholars.utp.edu.my/id/eprint/3094/
http://scholars.utp.edu.my/id/eprint/3094/1/WEC-CBIT015.pdf