Impact of different spacer filament geometries on concentration polarization control in narrow membrane channel

Fluid flow condition adjacent to the membrane interface plays a vital role in controlling mass transfer and concentration polarization mechanism across the membrane. Thus, optimized design of spacer is crucial to deter the formation of concentration polarization layer while maintaining certain degre...

Full description

Bibliographic Details
Main Authors: Ahmad , A.L., Lau, K.K., Abu Bakar, M.Z.
Format: Article
Published: Elsevier B.V. 2005
Subjects:
Online Access:http://scholars.utp.edu.my/id/eprint/2674/
_version_ 1848659283484344320
author Ahmad , A.L.
Lau, K.K.
Abu Bakar, M.Z.
author_facet Ahmad , A.L.
Lau, K.K.
Abu Bakar, M.Z.
author_sort Ahmad , A.L.
building UTP Institutional Repository
collection Online Access
description Fluid flow condition adjacent to the membrane interface plays a vital role in controlling mass transfer and concentration polarization mechanism across the membrane. Thus, optimized design of spacer is crucial to deter the formation of concentration polarization layer while maintaining certain degree of pressure drop. The main objective of this paper is to integrate the permeation properties in commercial CFD codes FLUENT 6 for simulating flow conditions and permeation properties in the spacer-filled narrow membrane channel. Turbulence model have been integrated in the solution of time averaged incompressible flow equations. Different types of spacer filament geometries have been analyzed and evaluated to determine their ability in controlling concentration polarization and pressure drop. This study has also demonstrated the dependency of filament geometries performance on feed Reynolds number. This method potentially offers faster approach to determine the optimum geometries of spacer filament in the narrow membrane channel if compared with experimental methods.
first_indexed 2025-11-13T07:27:58Z
format Article
id oai:scholars.utp.edu.my:2674
institution Universiti Teknologi Petronas
institution_category Local University
last_indexed 2025-11-13T07:27:58Z
publishDate 2005
publisher Elsevier B.V.
recordtype eprints
repository_type Digital Repository
spelling oai:scholars.utp.edu.my:26742010-08-05T04:06:24Z http://scholars.utp.edu.my/id/eprint/2674/ Impact of different spacer filament geometries on concentration polarization control in narrow membrane channel Ahmad , A.L. Lau, K.K. Abu Bakar, M.Z. TP Chemical technology Fluid flow condition adjacent to the membrane interface plays a vital role in controlling mass transfer and concentration polarization mechanism across the membrane. Thus, optimized design of spacer is crucial to deter the formation of concentration polarization layer while maintaining certain degree of pressure drop. The main objective of this paper is to integrate the permeation properties in commercial CFD codes FLUENT 6 for simulating flow conditions and permeation properties in the spacer-filled narrow membrane channel. Turbulence model have been integrated in the solution of time averaged incompressible flow equations. Different types of spacer filament geometries have been analyzed and evaluated to determine their ability in controlling concentration polarization and pressure drop. This study has also demonstrated the dependency of filament geometries performance on feed Reynolds number. This method potentially offers faster approach to determine the optimum geometries of spacer filament in the narrow membrane channel if compared with experimental methods. Elsevier B.V. 2005 Article PeerReviewed Ahmad , A.L. and Lau, K.K. and Abu Bakar, M.Z. (2005) Impact of different spacer filament geometries on concentration polarization control in narrow membrane channel. Journal of Membrane Science, 262 (1). pp. 138-152. ISSN 3767388 http://www.elsevier.com/wps/find/journaldescription.cws_home/502692/description#description doi.org/10.1016/j.memsci.2005.06.056 doi.org/10.1016/j.memsci.2005.06.056
spellingShingle TP Chemical technology
Ahmad , A.L.
Lau, K.K.
Abu Bakar, M.Z.
Impact of different spacer filament geometries on concentration polarization control in narrow membrane channel
title Impact of different spacer filament geometries on concentration polarization control in narrow membrane channel
title_full Impact of different spacer filament geometries on concentration polarization control in narrow membrane channel
title_fullStr Impact of different spacer filament geometries on concentration polarization control in narrow membrane channel
title_full_unstemmed Impact of different spacer filament geometries on concentration polarization control in narrow membrane channel
title_short Impact of different spacer filament geometries on concentration polarization control in narrow membrane channel
title_sort impact of different spacer filament geometries on concentration polarization control in narrow membrane channel
topic TP Chemical technology
url http://scholars.utp.edu.my/id/eprint/2674/
http://scholars.utp.edu.my/id/eprint/2674/
http://scholars.utp.edu.my/id/eprint/2674/