PERFORMANCE OF BONDING MATERIAL IN SEMI-PRECAST CONCRETE SLAB

Bonding between old and new concrete is a potential area of research particularly in precast and semi precast construction. Precast and semi precast constructions are widely used in the industry because of advantages of labour reduction, short construction duration and cost effectiveness. The conv...

Full description

Bibliographic Details
Main Authors: Doh, S.I., Ideris, Z., Narayanan,, S.P, Kurian, V.J., Gungat, L.
Format: Conference or Workshop Item
Language:English
Published: World Engineering Congress 2007
Subjects:
Online Access:http://scholars.utp.edu.my/id/eprint/1232/
http://scholars.utp.edu.my/id/eprint/1232/1/WEC_2007%2C_August%2C_Penang_%28KVJ%29.pdf
_version_ 1848659089119248384
author Doh, S.I.
Ideris, Z.
Narayanan,, S.P
Kurian, V.J.
Gungat, L.
author_facet Doh, S.I.
Ideris, Z.
Narayanan,, S.P
Kurian, V.J.
Gungat, L.
author_sort Doh, S.I.
building UTP Institutional Repository
collection Online Access
description Bonding between old and new concrete is a potential area of research particularly in precast and semi precast construction. Precast and semi precast constructions are widely used in the industry because of advantages of labour reduction, short construction duration and cost effectiveness. The conventional cast in situ method forms a monolithic structure and is preferred. Many failures have occurred in slabs due to the debonding between the precast and cast in situ parts. The bond performance between the old and the new concrete plays an important role in the structural performance. Improper bonding between semi- precast concrete and cast in situ topping will cause relative shrinkage between them and finally lead to cracking that may promote the corrosion of steel reinforcement due to the penetration of chloride ions, water and other hazardous substances. Bonding also depends on the structuring of the fresh concrete in direct contact with the old surface. One precast and three semi precast slabs were cast first without bonding material (NB) and then with two different bonding materials namely cement slurry (CS) and SikaLatex (SIKA) applied between the precast and cast in situ topping. Semiprecast slab without bonding material and the precast slab were used as the control slabs. The effectiveness of different types of binder in bonding the new and the old concrete of slabs was studied by structural testing. The result is evaluated on basis of deflection and cracking behaviour of the slabs. The investigation revealed that the use of bonding material does not have very significant impact on the performance of the slabs.
first_indexed 2025-11-13T07:24:53Z
format Conference or Workshop Item
id oai:scholars.utp.edu.my:1232
institution Universiti Teknologi Petronas
institution_category Local University
language English
last_indexed 2025-11-13T07:24:53Z
publishDate 2007
publisher World Engineering Congress
recordtype eprints
repository_type Digital Repository
spelling oai:scholars.utp.edu.my:12322017-01-19T08:26:54Z http://scholars.utp.edu.my/id/eprint/1232/ PERFORMANCE OF BONDING MATERIAL IN SEMI-PRECAST CONCRETE SLAB Doh, S.I. Ideris, Z. Narayanan,, S.P Kurian, V.J. Gungat, L. TA Engineering (General). Civil engineering (General) Bonding between old and new concrete is a potential area of research particularly in precast and semi precast construction. Precast and semi precast constructions are widely used in the industry because of advantages of labour reduction, short construction duration and cost effectiveness. The conventional cast in situ method forms a monolithic structure and is preferred. Many failures have occurred in slabs due to the debonding between the precast and cast in situ parts. The bond performance between the old and the new concrete plays an important role in the structural performance. Improper bonding between semi- precast concrete and cast in situ topping will cause relative shrinkage between them and finally lead to cracking that may promote the corrosion of steel reinforcement due to the penetration of chloride ions, water and other hazardous substances. Bonding also depends on the structuring of the fresh concrete in direct contact with the old surface. One precast and three semi precast slabs were cast first without bonding material (NB) and then with two different bonding materials namely cement slurry (CS) and SikaLatex (SIKA) applied between the precast and cast in situ topping. Semiprecast slab without bonding material and the precast slab were used as the control slabs. The effectiveness of different types of binder in bonding the new and the old concrete of slabs was studied by structural testing. The result is evaluated on basis of deflection and cracking behaviour of the slabs. The investigation revealed that the use of bonding material does not have very significant impact on the performance of the slabs. World Engineering Congress 2007-08 Conference or Workshop Item PeerReviewed application/pdf en http://scholars.utp.edu.my/id/eprint/1232/1/WEC_2007%2C_August%2C_Penang_%28KVJ%29.pdf Doh, S.I. and Ideris, Z. and Narayanan,, S.P and Kurian, V.J. and Gungat, L. (2007) PERFORMANCE OF BONDING MATERIAL IN SEMI-PRECAST CONCRETE SLAB. In: World Engineering Congress, 5-9 August 2007, Penang.
spellingShingle TA Engineering (General). Civil engineering (General)
Doh, S.I.
Ideris, Z.
Narayanan,, S.P
Kurian, V.J.
Gungat, L.
PERFORMANCE OF BONDING MATERIAL IN SEMI-PRECAST CONCRETE SLAB
title PERFORMANCE OF BONDING MATERIAL IN SEMI-PRECAST CONCRETE SLAB
title_full PERFORMANCE OF BONDING MATERIAL IN SEMI-PRECAST CONCRETE SLAB
title_fullStr PERFORMANCE OF BONDING MATERIAL IN SEMI-PRECAST CONCRETE SLAB
title_full_unstemmed PERFORMANCE OF BONDING MATERIAL IN SEMI-PRECAST CONCRETE SLAB
title_short PERFORMANCE OF BONDING MATERIAL IN SEMI-PRECAST CONCRETE SLAB
title_sort performance of bonding material in semi-precast concrete slab
topic TA Engineering (General). Civil engineering (General)
url http://scholars.utp.edu.my/id/eprint/1232/
http://scholars.utp.edu.my/id/eprint/1232/1/WEC_2007%2C_August%2C_Penang_%28KVJ%29.pdf