Seismic Retrofit of Elevated Steel Water Tanks

The Indian Standard “Criteria for Earthquake Resistant Design of Structures: IS 1893-1984” was revised in 2002. Areas in earthquake zone 1 were merged to earthquake zone 2 and the place Killari is now in earthquake zone 3. The seismic zone factors have also changed. Response spectra are specified fo...

Full description

Bibliographic Details
Main Authors: Sambu Potty, Narayanan, Nambissan, Savitha
Format: Conference or Workshop Item
Language:English
Published: 2008
Subjects:
Online Access:http://scholars.utp.edu.my/id/eprint/1044/
http://scholars.utp.edu.my/id/eprint/1044/1/C014.pdf
_version_ 1848659067995684864
author Sambu Potty, Narayanan
Nambissan, Savitha
author_facet Sambu Potty, Narayanan
Nambissan, Savitha
author_sort Sambu Potty, Narayanan
building UTP Institutional Repository
collection Online Access
description The Indian Standard “Criteria for Earthquake Resistant Design of Structures: IS 1893-1984” was revised in 2002. Areas in earthquake zone 1 were merged to earthquake zone 2 and the place Killari is now in earthquake zone 3. The seismic zone factors have also changed. Response spectra are specified for 3 types of founding soil strata and a response reduction factor was been introduced. Elevated water tanks are vulnerable to earthquake, owing to large mass concentrated at the top of a relatively slender supporting structure. In this paper, existing elevated steel water tanks in India designed using IS 1893-1984 was checked for safety as per revised code (IS 1893-2002) by carrying out static and forced dynamic analysis. It was observed that the structure was unsafe due to under-estimation of seismic load as per old code provisions. Retrofit measures such as additional structural elements and passive devices like viscous and friction dampers were modelled and structure analysed again to check for compliance with the revised code. Conclusions drawn from this study are presented.
first_indexed 2025-11-13T07:24:32Z
format Conference or Workshop Item
id oai:scholars.utp.edu.my:1044
institution Universiti Teknologi Petronas
institution_category Local University
language English
last_indexed 2025-11-13T07:24:32Z
publishDate 2008
recordtype eprints
repository_type Digital Repository
spelling oai:scholars.utp.edu.my:10442017-01-19T08:26:13Z http://scholars.utp.edu.my/id/eprint/1044/ Seismic Retrofit of Elevated Steel Water Tanks Sambu Potty, Narayanan Nambissan, Savitha TA Engineering (General). Civil engineering (General) The Indian Standard “Criteria for Earthquake Resistant Design of Structures: IS 1893-1984” was revised in 2002. Areas in earthquake zone 1 were merged to earthquake zone 2 and the place Killari is now in earthquake zone 3. The seismic zone factors have also changed. Response spectra are specified for 3 types of founding soil strata and a response reduction factor was been introduced. Elevated water tanks are vulnerable to earthquake, owing to large mass concentrated at the top of a relatively slender supporting structure. In this paper, existing elevated steel water tanks in India designed using IS 1893-1984 was checked for safety as per revised code (IS 1893-2002) by carrying out static and forced dynamic analysis. It was observed that the structure was unsafe due to under-estimation of seismic load as per old code provisions. Retrofit measures such as additional structural elements and passive devices like viscous and friction dampers were modelled and structure analysed again to check for compliance with the revised code. Conclusions drawn from this study are presented. 2008-06-16 Conference or Workshop Item PeerReviewed application/pdf en http://scholars.utp.edu.my/id/eprint/1044/1/C014.pdf Sambu Potty, Narayanan and Nambissan, Savitha (2008) Seismic Retrofit of Elevated Steel Water Tanks. In: International Conference on Construction and Building Technology (ICCBT), June 16- 20, Kuala Lumpur.
spellingShingle TA Engineering (General). Civil engineering (General)
Sambu Potty, Narayanan
Nambissan, Savitha
Seismic Retrofit of Elevated Steel Water Tanks
title Seismic Retrofit of Elevated Steel Water Tanks
title_full Seismic Retrofit of Elevated Steel Water Tanks
title_fullStr Seismic Retrofit of Elevated Steel Water Tanks
title_full_unstemmed Seismic Retrofit of Elevated Steel Water Tanks
title_short Seismic Retrofit of Elevated Steel Water Tanks
title_sort seismic retrofit of elevated steel water tanks
topic TA Engineering (General). Civil engineering (General)
url http://scholars.utp.edu.my/id/eprint/1044/
http://scholars.utp.edu.my/id/eprint/1044/1/C014.pdf