Measurement of Dosimetric Parameters and Dose Verification in Stereotactic Radiosurgery (SRS)

The first part of this study was about measurement of dosimetric parameters for small photon beams to be used as input data for treatment planning computer system (TPS) and to verify the dose calculated by TPS in Stereotactic Radiosurgery (SRS) procedure. The beam data required were percentage depth...

Full description

Bibliographic Details
Main Authors: Reduan Abdullah, Nik Ruzman Nik Idris, Ahmad Zakaria, Ahmad Lutfi Yusof, Mazurawati Mohamed, Nur Iziana Mohsin
Format: Article
Language:English
Published: Penerbit UKM 2015
Subjects:
Online Access:http://journalarticle.ukm.my/9013/
http://journalarticle.ukm.my/9013/1/9468-26163-1-PB.pdf
_version_ 1848811955614121984
author Reduan Abdullah,
Nik Ruzman Nik Idris,
Ahmad Zakaria,
Ahmad Lutfi Yusof,
Mazurawati Mohamed,
Nur Iziana Mohsin,
author_facet Reduan Abdullah,
Nik Ruzman Nik Idris,
Ahmad Zakaria,
Ahmad Lutfi Yusof,
Mazurawati Mohamed,
Nur Iziana Mohsin,
author_sort Reduan Abdullah,
building UKM Institutional Repository
collection Online Access
description The first part of this study was about measurement of dosimetric parameters for small photon beams to be used as input data for treatment planning computer system (TPS) and to verify the dose calculated by TPS in Stereotactic Radiosurgery (SRS) procedure. The beam data required were percentage depth dose (PDD), off-axis ratio (OAR) and scattering factor. Small beams of 5 mm to 45 mm diameter from a circular cone collimator in SRS were used for beam data measurements. Measurements were made using pinpoint ionisation chamber (0.016cc). In the second part of this study, we reported the important of carrying out quality assurance (QA) procedures before SRS treatment which were found to infl uence the accuracy of dose delivery. These QA procedures consisted of measurements on the accuracy in target localization and treatment room laser alignment. The calculated TPS dose for treatment was verifi ed using pinpoint ionisation chamber and thermoluminescent detector (TLD) 100H. The deviation mean between measured and calculated dose was -3.28%. The measured dose obtained from pinpoint ionisation chamber is in good agreement with the calculated dose from TPS with deviation mean of 2.17%. In conclusion, pinpoint ionisation chamber gives a better accuracy in dose calculation compared to TLD 100H. The results are acceptable as recommended by International Commission on Radiation Units and Measurements (ICRU) Report No. 50 (1994) that dose delivered to the target volume must be within ± 5% error.
first_indexed 2025-11-14T23:54:37Z
format Article
id oai:generic.eprints.org:9013
institution Universiti Kebangasaan Malaysia
institution_category Local University
language English
last_indexed 2025-11-14T23:54:37Z
publishDate 2015
publisher Penerbit UKM
recordtype eprints
repository_type Digital Repository
spelling oai:generic.eprints.org:90132016-12-14T06:48:43Z http://journalarticle.ukm.my/9013/ Measurement of Dosimetric Parameters and Dose Verification in Stereotactic Radiosurgery (SRS) Reduan Abdullah, Nik Ruzman Nik Idris, Ahmad Zakaria, Ahmad Lutfi Yusof, Mazurawati Mohamed, Nur Iziana Mohsin, RA Public aspects of medicine The first part of this study was about measurement of dosimetric parameters for small photon beams to be used as input data for treatment planning computer system (TPS) and to verify the dose calculated by TPS in Stereotactic Radiosurgery (SRS) procedure. The beam data required were percentage depth dose (PDD), off-axis ratio (OAR) and scattering factor. Small beams of 5 mm to 45 mm diameter from a circular cone collimator in SRS were used for beam data measurements. Measurements were made using pinpoint ionisation chamber (0.016cc). In the second part of this study, we reported the important of carrying out quality assurance (QA) procedures before SRS treatment which were found to infl uence the accuracy of dose delivery. These QA procedures consisted of measurements on the accuracy in target localization and treatment room laser alignment. The calculated TPS dose for treatment was verifi ed using pinpoint ionisation chamber and thermoluminescent detector (TLD) 100H. The deviation mean between measured and calculated dose was -3.28%. The measured dose obtained from pinpoint ionisation chamber is in good agreement with the calculated dose from TPS with deviation mean of 2.17%. In conclusion, pinpoint ionisation chamber gives a better accuracy in dose calculation compared to TLD 100H. The results are acceptable as recommended by International Commission on Radiation Units and Measurements (ICRU) Report No. 50 (1994) that dose delivered to the target volume must be within ± 5% error. Penerbit UKM 2015 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/9013/1/9468-26163-1-PB.pdf Reduan Abdullah, and Nik Ruzman Nik Idris, and Ahmad Zakaria, and Ahmad Lutfi Yusof, and Mazurawati Mohamed, and Nur Iziana Mohsin, (2015) Measurement of Dosimetric Parameters and Dose Verification in Stereotactic Radiosurgery (SRS). Jurnal Sains Kesihatan Malaysia, 13 (1). pp. 39-49. ISSN 1675-8161 http://ejournal.ukm.my/jskm/issue/view/588
spellingShingle RA Public aspects of medicine
Reduan Abdullah,
Nik Ruzman Nik Idris,
Ahmad Zakaria,
Ahmad Lutfi Yusof,
Mazurawati Mohamed,
Nur Iziana Mohsin,
Measurement of Dosimetric Parameters and Dose Verification in Stereotactic Radiosurgery (SRS)
title Measurement of Dosimetric Parameters and Dose Verification in Stereotactic Radiosurgery (SRS)
title_full Measurement of Dosimetric Parameters and Dose Verification in Stereotactic Radiosurgery (SRS)
title_fullStr Measurement of Dosimetric Parameters and Dose Verification in Stereotactic Radiosurgery (SRS)
title_full_unstemmed Measurement of Dosimetric Parameters and Dose Verification in Stereotactic Radiosurgery (SRS)
title_short Measurement of Dosimetric Parameters and Dose Verification in Stereotactic Radiosurgery (SRS)
title_sort measurement of dosimetric parameters and dose verification in stereotactic radiosurgery (srs)
topic RA Public aspects of medicine
url http://journalarticle.ukm.my/9013/
http://journalarticle.ukm.my/9013/
http://journalarticle.ukm.my/9013/1/9468-26163-1-PB.pdf