Carbon-Ion beam radiosensitivity study and biological responses of high-yieldingrice line, MR219-PL-5

The carbon ion-beam has emerged as a novel physical mutagen for creating genetic variability and crop improvement. In this study, seeds of a high-yielding pyramided rice line MR219-PL-5 were exposed to carbon ion beam irradiation at 10, 20, 40, 60, 80, and 100 Gy. The radiosensitivity test was condu...

Full description

Bibliographic Details
Main Authors: Asrapil Waitul Fifika, Asmuni Mohd Ikmal, Ahmad Faiz, Nor’aishah Hasan, Harun Abdul Rahim, Hussein Sobri, Noraziyah Abd Aziz Shamsudin
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2021
Online Access:http://journalarticle.ukm.my/18318/
http://journalarticle.ukm.my/18318/1/2.pdf
_version_ 1848814540276367360
author Asrapil Waitul Fifika,
Asmuni Mohd Ikmal,
Ahmad Faiz,
Nor’aishah Hasan,
Harun Abdul Rahim,
Hussein Sobri,
Noraziyah Abd Aziz Shamsudin,
author_facet Asrapil Waitul Fifika,
Asmuni Mohd Ikmal,
Ahmad Faiz,
Nor’aishah Hasan,
Harun Abdul Rahim,
Hussein Sobri,
Noraziyah Abd Aziz Shamsudin,
author_sort Asrapil Waitul Fifika,
building UKM Institutional Repository
collection Online Access
description The carbon ion-beam has emerged as a novel physical mutagen for creating genetic variability and crop improvement. In this study, seeds of a high-yielding pyramided rice line MR219-PL-5 were exposed to carbon ion beam irradiation at 10, 20, 40, 60, 80, and 100 Gy. The radiosensitivity test was conducted to determine the optimum dose of carbon ion beam irradiation based on the lethal dose 50% (LD50) using Sandwich Blotter Technique. The biological responses of carbon-ion beam irradiation were also observed in other characteristics such as germination rate (GeR), survival rate (SR), growth rate (GRoR), shoot length (SL), root length (RL), seedling height (SH), days to flowering (DTF), fertility rate (FR) and thousand-grains weight (TGW). Based on the polynomial curve of SR graph, the lethal dose 50% (LD50) value was 86.12 Gy. However, the optimum dose range of carbon ion-beam irradiation was between 40 and 60 Gy as these two doses recorded the highest SR, 63 and 67%, respectively. Furthermore, the shoulder dose in this study was 60 Gy since SR decreased significantly at higher doses. M1 individuals irradiated at 40 and 60 Gy had the best biological responses where significant differences were found for SR, SL, RL, GRoR, SH, DTF and FR at these two doses compared to the other doses. Further studies on M2 and M3 populations could help to identify potential individuals as well as to understand the inheritance of each trait of interest from one generation to the next.
first_indexed 2025-11-15T00:35:42Z
format Article
id oai:generic.eprints.org:18318
institution Universiti Kebangasaan Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T00:35:42Z
publishDate 2021
publisher Penerbit Universiti Kebangsaan Malaysia
recordtype eprints
repository_type Digital Repository
spelling oai:generic.eprints.org:183182022-04-11T04:33:58Z http://journalarticle.ukm.my/18318/ Carbon-Ion beam radiosensitivity study and biological responses of high-yieldingrice line, MR219-PL-5 Asrapil Waitul Fifika, Asmuni Mohd Ikmal, Ahmad Faiz, Nor’aishah Hasan, Harun Abdul Rahim, Hussein Sobri, Noraziyah Abd Aziz Shamsudin, The carbon ion-beam has emerged as a novel physical mutagen for creating genetic variability and crop improvement. In this study, seeds of a high-yielding pyramided rice line MR219-PL-5 were exposed to carbon ion beam irradiation at 10, 20, 40, 60, 80, and 100 Gy. The radiosensitivity test was conducted to determine the optimum dose of carbon ion beam irradiation based on the lethal dose 50% (LD50) using Sandwich Blotter Technique. The biological responses of carbon-ion beam irradiation were also observed in other characteristics such as germination rate (GeR), survival rate (SR), growth rate (GRoR), shoot length (SL), root length (RL), seedling height (SH), days to flowering (DTF), fertility rate (FR) and thousand-grains weight (TGW). Based on the polynomial curve of SR graph, the lethal dose 50% (LD50) value was 86.12 Gy. However, the optimum dose range of carbon ion-beam irradiation was between 40 and 60 Gy as these two doses recorded the highest SR, 63 and 67%, respectively. Furthermore, the shoulder dose in this study was 60 Gy since SR decreased significantly at higher doses. M1 individuals irradiated at 40 and 60 Gy had the best biological responses where significant differences were found for SR, SL, RL, GRoR, SH, DTF and FR at these two doses compared to the other doses. Further studies on M2 and M3 populations could help to identify potential individuals as well as to understand the inheritance of each trait of interest from one generation to the next. Penerbit Universiti Kebangsaan Malaysia 2021-12 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/18318/1/2.pdf Asrapil Waitul Fifika, and Asmuni Mohd Ikmal, and Ahmad Faiz, and Nor’aishah Hasan, and Harun Abdul Rahim, and Hussein Sobri, and Noraziyah Abd Aziz Shamsudin, (2021) Carbon-Ion beam radiosensitivity study and biological responses of high-yieldingrice line, MR219-PL-5. Sains Malaysiana, 50 (12). pp. 3481-3491. ISSN 0126-6039 https://www.ukm.my/jsm/malay_journals/jilid50bil12_2021/KandunganJilid50Bil12_2021.html
spellingShingle Asrapil Waitul Fifika,
Asmuni Mohd Ikmal,
Ahmad Faiz,
Nor’aishah Hasan,
Harun Abdul Rahim,
Hussein Sobri,
Noraziyah Abd Aziz Shamsudin,
Carbon-Ion beam radiosensitivity study and biological responses of high-yieldingrice line, MR219-PL-5
title Carbon-Ion beam radiosensitivity study and biological responses of high-yieldingrice line, MR219-PL-5
title_full Carbon-Ion beam radiosensitivity study and biological responses of high-yieldingrice line, MR219-PL-5
title_fullStr Carbon-Ion beam radiosensitivity study and biological responses of high-yieldingrice line, MR219-PL-5
title_full_unstemmed Carbon-Ion beam radiosensitivity study and biological responses of high-yieldingrice line, MR219-PL-5
title_short Carbon-Ion beam radiosensitivity study and biological responses of high-yieldingrice line, MR219-PL-5
title_sort carbon-ion beam radiosensitivity study and biological responses of high-yieldingrice line, mr219-pl-5
url http://journalarticle.ukm.my/18318/
http://journalarticle.ukm.my/18318/
http://journalarticle.ukm.my/18318/1/2.pdf