Correlation of corneal thickness measurements between tono-pachymeter and scheimpflug-placido topography

Central corneal thickness (CCT) measurements are important for diagnosis,treatment, and surgery planning in ophthalmology. The purpose of this study was to see whether CCT measurements taken with Tono-pachymeter and Scheimpflug-Placido Topography had any significant differences. Tono-pachymeter an...

Full description

Bibliographic Details
Main Author: Ercan, Zeynep Eylül
Format: Article
Language:English
Published: Pusat Perubatan Universiti Kebangsaan Malaysia 2021
Online Access:http://journalarticle.ukm.my/18274/
http://journalarticle.ukm.my/18274/1/12_ms0505_pdf_10844.pdf
_version_ 1848814528620396544
author Ercan, Zeynep Eylül
author_facet Ercan, Zeynep Eylül
author_sort Ercan, Zeynep Eylül
building UKM Institutional Repository
collection Online Access
description Central corneal thickness (CCT) measurements are important for diagnosis,treatment, and surgery planning in ophthalmology. The purpose of this study was to see whether CCT measurements taken with Tono-pachymeter and Scheimpflug-Placido Topography had any significant differences. Tono-pachymeter and topography CCT measurements were taken (n=400). Inter-measurement agreement between them was determined using Bland-Altman Plot analysis. Age groups were also formed as group 1 (aged 18-50 years, 94 males, 106 females) and group 2 (age >51 years, 100 males, 100 females). Mean CCTs measured by Tono-pachymeter and topography were 563.77 +±26.43 and 560.88 + 26.341 microns. Bland-Altman Plot analysis showed in total, 13 were above the upper limit and 5 were under the minimum limit of agreement with regression analysis showing no significant relationships (p=0.213). Group 1 had 7 above and 2 below from the limits of agreement. Group two had 9 above and 2 below from the limits of agreement. Both groups showed insignificant differences between devices (p=0.07 and p=0.86). Tono-pachymeter and Scheimpflug-Placido Topography give reliable CCT results within each other. However, since the limit of agreement ranges can still affect one-to-one patient evaluations, we recommend clinics that use these devices to not interchange measurements in practice.
first_indexed 2025-11-15T00:35:31Z
format Article
id oai:generic.eprints.org:18274
institution Universiti Kebangasaan Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T00:35:31Z
publishDate 2021
publisher Pusat Perubatan Universiti Kebangsaan Malaysia
recordtype eprints
repository_type Digital Repository
spelling oai:generic.eprints.org:182742022-03-25T01:48:23Z http://journalarticle.ukm.my/18274/ Correlation of corneal thickness measurements between tono-pachymeter and scheimpflug-placido topography Ercan, Zeynep Eylül Central corneal thickness (CCT) measurements are important for diagnosis,treatment, and surgery planning in ophthalmology. The purpose of this study was to see whether CCT measurements taken with Tono-pachymeter and Scheimpflug-Placido Topography had any significant differences. Tono-pachymeter and topography CCT measurements were taken (n=400). Inter-measurement agreement between them was determined using Bland-Altman Plot analysis. Age groups were also formed as group 1 (aged 18-50 years, 94 males, 106 females) and group 2 (age >51 years, 100 males, 100 females). Mean CCTs measured by Tono-pachymeter and topography were 563.77 +±26.43 and 560.88 + 26.341 microns. Bland-Altman Plot analysis showed in total, 13 were above the upper limit and 5 were under the minimum limit of agreement with regression analysis showing no significant relationships (p=0.213). Group 1 had 7 above and 2 below from the limits of agreement. Group two had 9 above and 2 below from the limits of agreement. Both groups showed insignificant differences between devices (p=0.07 and p=0.86). Tono-pachymeter and Scheimpflug-Placido Topography give reliable CCT results within each other. However, since the limit of agreement ranges can still affect one-to-one patient evaluations, we recommend clinics that use these devices to not interchange measurements in practice. Pusat Perubatan Universiti Kebangsaan Malaysia 2021-12 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/18274/1/12_ms0505_pdf_10844.pdf Ercan, Zeynep Eylül (2021) Correlation of corneal thickness measurements between tono-pachymeter and scheimpflug-placido topography. Medicine & Health, 16 (2). pp. 161-167. ISSN 2289-5728 https://medicineandhealthukm.com/toc/16/2
spellingShingle Ercan, Zeynep Eylül
Correlation of corneal thickness measurements between tono-pachymeter and scheimpflug-placido topography
title Correlation of corneal thickness measurements between tono-pachymeter and scheimpflug-placido topography
title_full Correlation of corneal thickness measurements between tono-pachymeter and scheimpflug-placido topography
title_fullStr Correlation of corneal thickness measurements between tono-pachymeter and scheimpflug-placido topography
title_full_unstemmed Correlation of corneal thickness measurements between tono-pachymeter and scheimpflug-placido topography
title_short Correlation of corneal thickness measurements between tono-pachymeter and scheimpflug-placido topography
title_sort correlation of corneal thickness measurements between tono-pachymeter and scheimpflug-placido topography
url http://journalarticle.ukm.my/18274/
http://journalarticle.ukm.my/18274/
http://journalarticle.ukm.my/18274/1/12_ms0505_pdf_10844.pdf