River water quality monitoring using statistical process control in Dungun River Basin, Terengganu, Malaysia
Water pollution keeps rising due to the industrialisation and urbanisation in Malaysia. This matter needs to be given serious attention to avoid further contamination of the river water. Therefore, the quality of river water should be measured to avoid water pollution. This study was carried out to...
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Penerbit Universiti Kebangsaan Malaysia
2021
|
| Online Access: | http://journalarticle.ukm.my/17834/ http://journalarticle.ukm.my/17834/1/jqma-17-1-paper8.pdf |
| _version_ | 1848814412630065152 |
|---|---|
| author | Tengku Nurul Aimi Balqis Tengku Malim Busu, Nor Aishah Ahad, |
| author_facet | Tengku Nurul Aimi Balqis Tengku Malim Busu, Nor Aishah Ahad, |
| author_sort | Tengku Nurul Aimi Balqis Tengku Malim Busu, |
| building | UKM Institutional Repository |
| collection | Online Access |
| description | Water pollution keeps rising due to the industrialisation and urbanisation in Malaysia. This matter needs to be given serious attention to avoid further contamination of the river water. Therefore, the quality of river water should be measured to avoid water pollution. This study was carried out to determine river water quality whether the water is safe for aquatic life or not at Dungun River Basin, Terengganu, based on the chemical parameters, which are the pH value and the Total Dissolved Solids (TDS). The water sampling was conducted at three separate sites along the river, and the distance between each station is approximately 2 km. Box plot, scatter plot, and control chart are being used in the analysis. The box plot results show that the water pH value and TDS level are normally distributed with no outliers. The scatter plot shows that the pH value and TDS level have a weak positive relationship with the correlation value of 0.4063. The control chart shows the pH value and TDS level are stable and within control. However, apart from the physical, chemical, and microbiological parameters, water quality must be accessed to ensure a high quality of drinking water. Based on the National Water Quality Standard (NWQS), the result shows that pH was classified as Class IV, while TDS was classified as Class IIA. Therefore, the river water required conventional treatment, but it still can be used for irrigation. |
| first_indexed | 2025-11-15T00:33:41Z |
| format | Article |
| id | oai:generic.eprints.org:17834 |
| institution | Universiti Kebangasaan Malaysia |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-15T00:33:41Z |
| publishDate | 2021 |
| publisher | Penerbit Universiti Kebangsaan Malaysia |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | oai:generic.eprints.org:178342022-01-07T00:34:52Z http://journalarticle.ukm.my/17834/ River water quality monitoring using statistical process control in Dungun River Basin, Terengganu, Malaysia Tengku Nurul Aimi Balqis Tengku Malim Busu, Nor Aishah Ahad, Water pollution keeps rising due to the industrialisation and urbanisation in Malaysia. This matter needs to be given serious attention to avoid further contamination of the river water. Therefore, the quality of river water should be measured to avoid water pollution. This study was carried out to determine river water quality whether the water is safe for aquatic life or not at Dungun River Basin, Terengganu, based on the chemical parameters, which are the pH value and the Total Dissolved Solids (TDS). The water sampling was conducted at three separate sites along the river, and the distance between each station is approximately 2 km. Box plot, scatter plot, and control chart are being used in the analysis. The box plot results show that the water pH value and TDS level are normally distributed with no outliers. The scatter plot shows that the pH value and TDS level have a weak positive relationship with the correlation value of 0.4063. The control chart shows the pH value and TDS level are stable and within control. However, apart from the physical, chemical, and microbiological parameters, water quality must be accessed to ensure a high quality of drinking water. Based on the National Water Quality Standard (NWQS), the result shows that pH was classified as Class IV, while TDS was classified as Class IIA. Therefore, the river water required conventional treatment, but it still can be used for irrigation. Penerbit Universiti Kebangsaan Malaysia 2021 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/17834/1/jqma-17-1-paper8.pdf Tengku Nurul Aimi Balqis Tengku Malim Busu, and Nor Aishah Ahad, (2021) River water quality monitoring using statistical process control in Dungun River Basin, Terengganu, Malaysia. Journal of Quality Measurement and Analysis, 17 (1). pp. 99-117. ISSN 1823-5670 https://www.ukm.my/jqma/jqma17-1/ |
| spellingShingle | Tengku Nurul Aimi Balqis Tengku Malim Busu, Nor Aishah Ahad, River water quality monitoring using statistical process control in Dungun River Basin, Terengganu, Malaysia |
| title | River water quality monitoring using statistical process control in Dungun River Basin, Terengganu, Malaysia |
| title_full | River water quality monitoring using statistical process control in Dungun River Basin, Terengganu, Malaysia |
| title_fullStr | River water quality monitoring using statistical process control in Dungun River Basin, Terengganu, Malaysia |
| title_full_unstemmed | River water quality monitoring using statistical process control in Dungun River Basin, Terengganu, Malaysia |
| title_short | River water quality monitoring using statistical process control in Dungun River Basin, Terengganu, Malaysia |
| title_sort | river water quality monitoring using statistical process control in dungun river basin, terengganu, malaysia |
| url | http://journalarticle.ukm.my/17834/ http://journalarticle.ukm.my/17834/ http://journalarticle.ukm.my/17834/1/jqma-17-1-paper8.pdf |