Vortex assisted liquid-liquid microextraction with back extraction of repaglinide, glibenclamide and glimepiride in water samples

A new analytical method based on vortex-assisted liquid-liquid microextraction with back extraction (VALLME-BE) coupled with high performance liquid chromatography was developed for the simultaneous determination of antidiabetic drugs; repaglinide, glibenclamide, and glimepiride in water samples....

Full description

Bibliographic Details
Main Authors: Sohaib Jumaah Owaid Luhaib, Noorfatimah Yahaya, Alshishani, Anas, Maizatul Najwa Jajuli, Mazidatulakmam Miskam
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2021
Online Access:http://journalarticle.ukm.my/17407/
http://journalarticle.ukm.my/17407/1/10.pdf
_version_ 1848814306471182336
author Sohaib Jumaah Owaid Luhaib,
Noorfatimah Yahaya,
Alshishani, Anas
Maizatul Najwa Jajuli,
Mazidatulakmam Miskam,
author_facet Sohaib Jumaah Owaid Luhaib,
Noorfatimah Yahaya,
Alshishani, Anas
Maizatul Najwa Jajuli,
Mazidatulakmam Miskam,
author_sort Sohaib Jumaah Owaid Luhaib,
building UKM Institutional Repository
collection Online Access
description A new analytical method based on vortex-assisted liquid-liquid microextraction with back extraction (VALLME-BE) coupled with high performance liquid chromatography was developed for the simultaneous determination of antidiabetic drugs; repaglinide, glibenclamide, and glimepiride in water samples. Chromatographic separation was achieved using C18 column (250 × 4.6 mm × 5 µm) and methanol-phosphate buffer (pH3.7) in the ratio of 70:30 v/v as a mobile phase at a flow rate of 1 mLmin-1. VALLME-BE was performed using 200 μL of n-octane dispersed into the aqueous sample (10 mL) with the aid of vortexing agitation. Then, the analytes were back-extracted from the organic solvent to 0.05 M NaOH (40 µL). Under these conditions, enrichment factor of 155-fold was achieved. The developed VALLME-BE method showed excellent linearity in the range of 30 to 1000 µgL-1 with limit of detection (LOD) of 0.41-1.66 µgL-1 and limit of quantification (LOQ) of 1.38-5.54. 41-1.66 µgL-1. VALLME-BE was applied for the determination of repaglinide, glibenclamide and glimepiride in water samples with the recoveries ranged from 83-109%. The relative standard deviation for inter-day and intra-day precision was less than 9.9%.
first_indexed 2025-11-15T00:31:59Z
format Article
id oai:generic.eprints.org:17407
institution Universiti Kebangasaan Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T00:31:59Z
publishDate 2021
publisher Penerbit Universiti Kebangsaan Malaysia
recordtype eprints
repository_type Digital Repository
spelling oai:generic.eprints.org:174072021-09-14T02:50:23Z http://journalarticle.ukm.my/17407/ Vortex assisted liquid-liquid microextraction with back extraction of repaglinide, glibenclamide and glimepiride in water samples Sohaib Jumaah Owaid Luhaib, Noorfatimah Yahaya, Alshishani, Anas Maizatul Najwa Jajuli, Mazidatulakmam Miskam, A new analytical method based on vortex-assisted liquid-liquid microextraction with back extraction (VALLME-BE) coupled with high performance liquid chromatography was developed for the simultaneous determination of antidiabetic drugs; repaglinide, glibenclamide, and glimepiride in water samples. Chromatographic separation was achieved using C18 column (250 × 4.6 mm × 5 µm) and methanol-phosphate buffer (pH3.7) in the ratio of 70:30 v/v as a mobile phase at a flow rate of 1 mLmin-1. VALLME-BE was performed using 200 μL of n-octane dispersed into the aqueous sample (10 mL) with the aid of vortexing agitation. Then, the analytes were back-extracted from the organic solvent to 0.05 M NaOH (40 µL). Under these conditions, enrichment factor of 155-fold was achieved. The developed VALLME-BE method showed excellent linearity in the range of 30 to 1000 µgL-1 with limit of detection (LOD) of 0.41-1.66 µgL-1 and limit of quantification (LOQ) of 1.38-5.54. 41-1.66 µgL-1. VALLME-BE was applied for the determination of repaglinide, glibenclamide and glimepiride in water samples with the recoveries ranged from 83-109%. The relative standard deviation for inter-day and intra-day precision was less than 9.9%. Penerbit Universiti Kebangsaan Malaysia 2021-05 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/17407/1/10.pdf Sohaib Jumaah Owaid Luhaib, and Noorfatimah Yahaya, and Alshishani, Anas and Maizatul Najwa Jajuli, and Mazidatulakmam Miskam, (2021) Vortex assisted liquid-liquid microextraction with back extraction of repaglinide, glibenclamide and glimepiride in water samples. Sains Malaysiana, 50 (5). pp. 1297-1307. ISSN 0126-6039 https://www.ukm.my/jsm/malay_journals/jilid50bil5_2021/KandunganJilid50Bil5_2021.html
spellingShingle Sohaib Jumaah Owaid Luhaib,
Noorfatimah Yahaya,
Alshishani, Anas
Maizatul Najwa Jajuli,
Mazidatulakmam Miskam,
Vortex assisted liquid-liquid microextraction with back extraction of repaglinide, glibenclamide and glimepiride in water samples
title Vortex assisted liquid-liquid microextraction with back extraction of repaglinide, glibenclamide and glimepiride in water samples
title_full Vortex assisted liquid-liquid microextraction with back extraction of repaglinide, glibenclamide and glimepiride in water samples
title_fullStr Vortex assisted liquid-liquid microextraction with back extraction of repaglinide, glibenclamide and glimepiride in water samples
title_full_unstemmed Vortex assisted liquid-liquid microextraction with back extraction of repaglinide, glibenclamide and glimepiride in water samples
title_short Vortex assisted liquid-liquid microextraction with back extraction of repaglinide, glibenclamide and glimepiride in water samples
title_sort vortex assisted liquid-liquid microextraction with back extraction of repaglinide, glibenclamide and glimepiride in water samples
url http://journalarticle.ukm.my/17407/
http://journalarticle.ukm.my/17407/
http://journalarticle.ukm.my/17407/1/10.pdf