Photothermal imaging using non-contact photopyroelectric method

Photothermal imaging is a non-destructive and contactless technique for testing and monitoring defect of materials. This work is demonstrated thermal images for film sample of Al, Cu, Ni, and Cu with artificial defect with sampling area of 10 mm × 12 mm (21 × 25 pixels), 10 mm × 14 mm (21 × 29 pix...

Full description

Bibliographic Details
Main Authors: Azura Amran, Nor Kamilah Saat, Nizam Tamchek, Ting, Lee Mon
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2020
Online Access:http://journalarticle.ukm.my/15405/
http://journalarticle.ukm.my/15405/1/18.pdf
_version_ 1848813792715079680
author Azura Amran,
Nor Kamilah Saat,
Nizam Tamchek,
Ting, Lee Mon
author_facet Azura Amran,
Nor Kamilah Saat,
Nizam Tamchek,
Ting, Lee Mon
author_sort Azura Amran,
building UKM Institutional Repository
collection Online Access
description Photothermal imaging is a non-destructive and contactless technique for testing and monitoring defect of materials. This work is demonstrated thermal images for film sample of Al, Cu, Ni, and Cu with artificial defect with sampling area of 10 mm × 12 mm (21 × 25 pixels), 10 mm × 14 mm (21 × 29 pixels), 10 mm × 14 mm (21 × 29 pixels), 10 mm × 10 mm (21 × 21 pixels) respectively, acquired by raster scanning with the step size of 500 µm at fixed frequency modulation of 6 Hz and lock in detection in the range of 50 to 500 mV depending of studied material. The thermal image of defect sample is successfully acquired by introducing artificial defect onto the sample of Cu film. The thermal signal is obtained by taking transmission measurement which is defined by the ratio of intensity with sample to without sample. This paper also involves a photopyroelectric non-contact configuration for thermal diffusivity of the Al, Cu, and Ni film samples. Normalization procedure was used to wipe out the amount of photopyroelectric cell media parameter that should usually known before the sample’s thermal diffusivity could be decided. In this case, sample Al, Cu, and Ni were nearly to literature values but therefore justified the suggested model, the thermal diffusivity acquired.
first_indexed 2025-11-15T00:23:49Z
format Article
id oai:generic.eprints.org:15405
institution Universiti Kebangasaan Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T00:23:49Z
publishDate 2020
publisher Penerbit Universiti Kebangsaan Malaysia
recordtype eprints
repository_type Digital Repository
spelling oai:generic.eprints.org:154052020-10-23T01:27:03Z http://journalarticle.ukm.my/15405/ Photothermal imaging using non-contact photopyroelectric method Azura Amran, Nor Kamilah Saat, Nizam Tamchek, Ting, Lee Mon Photothermal imaging is a non-destructive and contactless technique for testing and monitoring defect of materials. This work is demonstrated thermal images for film sample of Al, Cu, Ni, and Cu with artificial defect with sampling area of 10 mm × 12 mm (21 × 25 pixels), 10 mm × 14 mm (21 × 29 pixels), 10 mm × 14 mm (21 × 29 pixels), 10 mm × 10 mm (21 × 21 pixels) respectively, acquired by raster scanning with the step size of 500 µm at fixed frequency modulation of 6 Hz and lock in detection in the range of 50 to 500 mV depending of studied material. The thermal image of defect sample is successfully acquired by introducing artificial defect onto the sample of Cu film. The thermal signal is obtained by taking transmission measurement which is defined by the ratio of intensity with sample to without sample. This paper also involves a photopyroelectric non-contact configuration for thermal diffusivity of the Al, Cu, and Ni film samples. Normalization procedure was used to wipe out the amount of photopyroelectric cell media parameter that should usually known before the sample’s thermal diffusivity could be decided. In this case, sample Al, Cu, and Ni were nearly to literature values but therefore justified the suggested model, the thermal diffusivity acquired. Penerbit Universiti Kebangsaan Malaysia 2020-05 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/15405/1/18.pdf Azura Amran, and Nor Kamilah Saat, and Nizam Tamchek, and Ting, Lee Mon (2020) Photothermal imaging using non-contact photopyroelectric method. Sains Malaysiana, 49 (5). pp. 1129-1136. ISSN 0126-6039 http://www.ukm.my/jsm/malay_journals/jilid49bil5_2020/KandunganJilid49Bil5_2020.html
spellingShingle Azura Amran,
Nor Kamilah Saat,
Nizam Tamchek,
Ting, Lee Mon
Photothermal imaging using non-contact photopyroelectric method
title Photothermal imaging using non-contact photopyroelectric method
title_full Photothermal imaging using non-contact photopyroelectric method
title_fullStr Photothermal imaging using non-contact photopyroelectric method
title_full_unstemmed Photothermal imaging using non-contact photopyroelectric method
title_short Photothermal imaging using non-contact photopyroelectric method
title_sort photothermal imaging using non-contact photopyroelectric method
url http://journalarticle.ukm.my/15405/
http://journalarticle.ukm.my/15405/
http://journalarticle.ukm.my/15405/1/18.pdf