Simple and sensitive electrokinetic supercharging in capillary electrophoresis for online preconcentration and separation of secbumeton in water samples

This study describes an electrokinetic supercharging for online preconcentration capillary electrophoresis (CE) technique of secbumeton in water samples. Important CE separation and preconcentration conditions, such as concentration and pH of the background electrolyte, applied voltage and ultraviol...

Full description

Bibliographic Details
Main Authors: Soeung, Rasmey, Nadhiratul-Farihin Semail, Wan Adnan Wan Omar, Nur Nadhirah Mohamad Zain, Mazidatulakmam Miskam, Yong, Foo Wong, Aemi Syazwani Abdul Keyon, Muggundha Raoov Ramachandran, Sazlinda Kamaruzaman, Noorfatimah Yahaya
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2020
Online Access:http://journalarticle.ukm.my/15388/
http://journalarticle.ukm.my/15388/1/2.pdf
_version_ 1848813788594176000
author Soeung, Rasmey
Nadhiratul-Farihin Semail,
Wan Adnan Wan Omar,
Nur Nadhirah Mohamad Zain,
Mazidatulakmam Miskam,
Yong, Foo Wong
Aemi Syazwani Abdul Keyon,
Muggundha Raoov Ramachandran,
Sazlinda Kamaruzaman,
Noorfatimah Yahaya,
author_facet Soeung, Rasmey
Nadhiratul-Farihin Semail,
Wan Adnan Wan Omar,
Nur Nadhirah Mohamad Zain,
Mazidatulakmam Miskam,
Yong, Foo Wong
Aemi Syazwani Abdul Keyon,
Muggundha Raoov Ramachandran,
Sazlinda Kamaruzaman,
Noorfatimah Yahaya,
author_sort Soeung, Rasmey
building UKM Institutional Repository
collection Online Access
description This study describes an electrokinetic supercharging for online preconcentration capillary electrophoresis (CE) technique of secbumeton in water samples. Important CE separation and preconcentration conditions, such as concentration and pH of the background electrolyte, applied voltage and ultraviolet wavelength, type and injection time of the terminating electrolyte, and injection time of the leading electrolyte and sample were investigated and optimized. The optimum conditions involved hydrodynamic injection of leading electrolyte (100 mM sodium chloride, 30 s, 50 mbar), electrokinetic injection of the sample as high as 250 s (at +7 kV voltage), and hydrodynamic injection of terminating electrolyte (100 mM Tris buffer, 40 s, 50 mbar). This strategy enhanced secbumeton detection sensitivity up to 3847-fold and 2267-fold when compared with hydrodynamic and electrokinetic injection, respectively, providing a limit of detection as low as 0.03 µg L–1 with good repeatability (relative standard deviation < 4%, n = 5). Wide linear range (0.1–500 µg L–1) with good linearity (R2 = 0.9997) was obtained. The limit of detection was adequate for the analysis of secbumeton in water samples with concentrations lower than its maximum residual limit (0.1 µg L–1). The developed method was applied to environmental water samples, and recoveries were between 85.7 and 105.6%.
first_indexed 2025-11-15T00:23:45Z
format Article
id oai:generic.eprints.org:15388
institution Universiti Kebangasaan Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T00:23:45Z
publishDate 2020
publisher Penerbit Universiti Kebangsaan Malaysia
recordtype eprints
repository_type Digital Repository
spelling oai:generic.eprints.org:153882020-10-23T00:43:50Z http://journalarticle.ukm.my/15388/ Simple and sensitive electrokinetic supercharging in capillary electrophoresis for online preconcentration and separation of secbumeton in water samples Soeung, Rasmey Nadhiratul-Farihin Semail, Wan Adnan Wan Omar, Nur Nadhirah Mohamad Zain, Mazidatulakmam Miskam, Yong, Foo Wong Aemi Syazwani Abdul Keyon, Muggundha Raoov Ramachandran, Sazlinda Kamaruzaman, Noorfatimah Yahaya, This study describes an electrokinetic supercharging for online preconcentration capillary electrophoresis (CE) technique of secbumeton in water samples. Important CE separation and preconcentration conditions, such as concentration and pH of the background electrolyte, applied voltage and ultraviolet wavelength, type and injection time of the terminating electrolyte, and injection time of the leading electrolyte and sample were investigated and optimized. The optimum conditions involved hydrodynamic injection of leading electrolyte (100 mM sodium chloride, 30 s, 50 mbar), electrokinetic injection of the sample as high as 250 s (at +7 kV voltage), and hydrodynamic injection of terminating electrolyte (100 mM Tris buffer, 40 s, 50 mbar). This strategy enhanced secbumeton detection sensitivity up to 3847-fold and 2267-fold when compared with hydrodynamic and electrokinetic injection, respectively, providing a limit of detection as low as 0.03 µg L–1 with good repeatability (relative standard deviation < 4%, n = 5). Wide linear range (0.1–500 µg L–1) with good linearity (R2 = 0.9997) was obtained. The limit of detection was adequate for the analysis of secbumeton in water samples with concentrations lower than its maximum residual limit (0.1 µg L–1). The developed method was applied to environmental water samples, and recoveries were between 85.7 and 105.6%. Penerbit Universiti Kebangsaan Malaysia 2020-05 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/15388/1/2.pdf Soeung, Rasmey and Nadhiratul-Farihin Semail, and Wan Adnan Wan Omar, and Nur Nadhirah Mohamad Zain, and Mazidatulakmam Miskam, and Yong, Foo Wong and Aemi Syazwani Abdul Keyon, and Muggundha Raoov Ramachandran, and Sazlinda Kamaruzaman, and Noorfatimah Yahaya, (2020) Simple and sensitive electrokinetic supercharging in capillary electrophoresis for online preconcentration and separation of secbumeton in water samples. Sains Malaysiana, 49 (5). pp. 979-988. ISSN 0126-6039 http://www.ukm.my/jsm/english_journals/vol49num5_2020/contentsVol49num5_2020.html
spellingShingle Soeung, Rasmey
Nadhiratul-Farihin Semail,
Wan Adnan Wan Omar,
Nur Nadhirah Mohamad Zain,
Mazidatulakmam Miskam,
Yong, Foo Wong
Aemi Syazwani Abdul Keyon,
Muggundha Raoov Ramachandran,
Sazlinda Kamaruzaman,
Noorfatimah Yahaya,
Simple and sensitive electrokinetic supercharging in capillary electrophoresis for online preconcentration and separation of secbumeton in water samples
title Simple and sensitive electrokinetic supercharging in capillary electrophoresis for online preconcentration and separation of secbumeton in water samples
title_full Simple and sensitive electrokinetic supercharging in capillary electrophoresis for online preconcentration and separation of secbumeton in water samples
title_fullStr Simple and sensitive electrokinetic supercharging in capillary electrophoresis for online preconcentration and separation of secbumeton in water samples
title_full_unstemmed Simple and sensitive electrokinetic supercharging in capillary electrophoresis for online preconcentration and separation of secbumeton in water samples
title_short Simple and sensitive electrokinetic supercharging in capillary electrophoresis for online preconcentration and separation of secbumeton in water samples
title_sort simple and sensitive electrokinetic supercharging in capillary electrophoresis for online preconcentration and separation of secbumeton in water samples
url http://journalarticle.ukm.my/15388/
http://journalarticle.ukm.my/15388/
http://journalarticle.ukm.my/15388/1/2.pdf