Monte Carlo investigation on neutron dosimetry parameters of 252Cf Isotron brachytherapy source

In the present study, all dosimetry parameters around the 252Cf Isotron source for neutron brachytherapy were calculated. The 252Cf neutron energy spectrum was modeled using the Maxwellian spectrum. The calculations were performed using MCNPX.2.6.0 code based on the TG-43U1 protocol in the water med...

Full description

Bibliographic Details
Main Authors: Ahmadi, Ome Leila, Anbaran, Hossein Tavakoli
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2020
Online Access:http://journalarticle.ukm.my/15200/
http://journalarticle.ukm.my/15200/1/ARTIKEL%2024.pdf
_version_ 1848813739345707008
author Ahmadi, Ome Leila
Anbaran, Hossein Tavakoli
author_facet Ahmadi, Ome Leila
Anbaran, Hossein Tavakoli
author_sort Ahmadi, Ome Leila
building UKM Institutional Repository
collection Online Access
description In the present study, all dosimetry parameters around the 252Cf Isotron source for neutron brachytherapy were calculated. The 252Cf neutron energy spectrum was modeled using the Maxwellian spectrum. The calculations were performed using MCNPX.2.6.0 code based on the TG-43U1 protocol in the water medium. The neutron air kerma strength for the 252Cf Isotron source was computed as 0.3098 ± 0.0002 cGy cm2/μgh and the neutron dose rate constant was 6.559 ± 0.003 cGy/Uh. The anisotropy functions were calculated at intervals of 1, 2, 3, 4, and 5cm at different polar angles in the range of θ = 0̊ to 90º in respect to the source long axis in a water Phantom. The uncertainty of the calculated data at all distances is less than 1%. The radial dose function at different distances from the source for the Isotron model was compared with the theoretical HDR 252Cf source model. The discrepancies between the results were the highest at the distance of 0.5 cm, with relative differences of 5.64 %. For the 252Cf Isotron source, the data presented in this study provides better understanding on the dosimetric distribution of a theoretical neutron brachytherapy source, for potential clinical application.
first_indexed 2025-11-15T00:22:58Z
format Article
id oai:generic.eprints.org:15200
institution Universiti Kebangasaan Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T00:22:58Z
publishDate 2020
publisher Penerbit Universiti Kebangsaan Malaysia
recordtype eprints
repository_type Digital Repository
spelling oai:generic.eprints.org:152002020-09-14T03:54:54Z http://journalarticle.ukm.my/15200/ Monte Carlo investigation on neutron dosimetry parameters of 252Cf Isotron brachytherapy source Ahmadi, Ome Leila Anbaran, Hossein Tavakoli In the present study, all dosimetry parameters around the 252Cf Isotron source for neutron brachytherapy were calculated. The 252Cf neutron energy spectrum was modeled using the Maxwellian spectrum. The calculations were performed using MCNPX.2.6.0 code based on the TG-43U1 protocol in the water medium. The neutron air kerma strength for the 252Cf Isotron source was computed as 0.3098 ± 0.0002 cGy cm2/μgh and the neutron dose rate constant was 6.559 ± 0.003 cGy/Uh. The anisotropy functions were calculated at intervals of 1, 2, 3, 4, and 5cm at different polar angles in the range of θ = 0̊ to 90º in respect to the source long axis in a water Phantom. The uncertainty of the calculated data at all distances is less than 1%. The radial dose function at different distances from the source for the Isotron model was compared with the theoretical HDR 252Cf source model. The discrepancies between the results were the highest at the distance of 0.5 cm, with relative differences of 5.64 %. For the 252Cf Isotron source, the data presented in this study provides better understanding on the dosimetric distribution of a theoretical neutron brachytherapy source, for potential clinical application. Penerbit Universiti Kebangsaan Malaysia 2020-03 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/15200/1/ARTIKEL%2024.pdf Ahmadi, Ome Leila and Anbaran, Hossein Tavakoli (2020) Monte Carlo investigation on neutron dosimetry parameters of 252Cf Isotron brachytherapy source. Sains Malaysiana, 49 (3). pp. 693-701. ISSN 0126-6039 http://www.ukm.my/jsm/malay_journals/jilid49bil3_2020/KandunganJilid49Bil3_2020.html
spellingShingle Ahmadi, Ome Leila
Anbaran, Hossein Tavakoli
Monte Carlo investigation on neutron dosimetry parameters of 252Cf Isotron brachytherapy source
title Monte Carlo investigation on neutron dosimetry parameters of 252Cf Isotron brachytherapy source
title_full Monte Carlo investigation on neutron dosimetry parameters of 252Cf Isotron brachytherapy source
title_fullStr Monte Carlo investigation on neutron dosimetry parameters of 252Cf Isotron brachytherapy source
title_full_unstemmed Monte Carlo investigation on neutron dosimetry parameters of 252Cf Isotron brachytherapy source
title_short Monte Carlo investigation on neutron dosimetry parameters of 252Cf Isotron brachytherapy source
title_sort monte carlo investigation on neutron dosimetry parameters of 252cf isotron brachytherapy source
url http://journalarticle.ukm.my/15200/
http://journalarticle.ukm.my/15200/
http://journalarticle.ukm.my/15200/1/ARTIKEL%2024.pdf