Refractive index and sensing of glucose molarities determined using Au-Cr K-SPR at 670/785 nm wavelength

In this paper, we determine the optical refractive indices of different molarities of glucose using nano-laminated gold/chromium (Au-Cr) thin film via Kretschmann-based Surface Plasmon Resonance (K-SPR) sensing with angular interrogation. The nano-laminated Au-Cr K-SPR sensor detects the glucose pre...

Full description

Bibliographic Details
Main Authors: P. Susthitha Menon, Mulyanti, Budi, Nur Akmar Jamil, Wulandari, Chandra, Nugroho, Harbi Setyo, Gan, Siew Mei, Noor Faizah Zainul Abidin, Hasanah, Lilik, Pawinanto, Roer Eka, Dilla Duryha Berhanuddin
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2019
Online Access:http://journalarticle.ukm.my/13718/
http://journalarticle.ukm.my/13718/1/13%20P.%20Susthitha%20Menon.pdf
_version_ 1848813355323621376
author P. Susthitha Menon,
Mulyanti, Budi
Nur Akmar Jamil,
Wulandari, Chandra
Nugroho, Harbi Setyo
Gan, Siew Mei
Noor Faizah Zainul Abidin,
Hasanah, Lilik
Pawinanto, Roer Eka
Dilla Duryha Berhanuddin,
author_facet P. Susthitha Menon,
Mulyanti, Budi
Nur Akmar Jamil,
Wulandari, Chandra
Nugroho, Harbi Setyo
Gan, Siew Mei
Noor Faizah Zainul Abidin,
Hasanah, Lilik
Pawinanto, Roer Eka
Dilla Duryha Berhanuddin,
author_sort P. Susthitha Menon,
building UKM Institutional Repository
collection Online Access
description In this paper, we determine the optical refractive indices of different molarities of glucose using nano-laminated gold/chromium (Au-Cr) thin film via Kretschmann-based Surface Plasmon Resonance (K-SPR) sensing with angular interrogation. The nano-laminated Au-Cr K-SPR sensor detects the glucose presence in low- and high-concentration of 4-12 mmol/L and 55-277 mmol/L, respectively, under the exposure of 670 nm and 785 nm optical wavelengths. The experimental results showed that the minimum limit of detection (LOD) of Au-Cr K-SPR is 4 mmol/L and the glucose sensor sensitivities are in average of 3.41 o/M and 2.73o/M at 670 nm and 785 nm optical wavelength, respectively. Stable sensitivity for each concentration also shown from the sensorgram results, indicates the stable performance of nano-laminated Au-Cr SPR sensor to detect glucose in the range from mmol/L up to dmol/L. Values of refractive indices for glucose molarities obtained are 1.33187 (4 mmol/L) and 1.3191 (4 mmol/L) at 670 and 785 nm wavelength, respectively. These RI values are beneficial for numerical simulation of glucose sensors using nano-laminated Au-Cr thin films which have been reported for the first time. The sensor can be eventually deployed in integrated photonic sensing devices comprising of multiple analyte detection for lab-on-chip (LoC) and point-of care (PoC) applications.
first_indexed 2025-11-15T00:16:52Z
format Article
id oai:generic.eprints.org:13718
institution Universiti Kebangasaan Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T00:16:52Z
publishDate 2019
publisher Penerbit Universiti Kebangsaan Malaysia
recordtype eprints
repository_type Digital Repository
spelling oai:generic.eprints.org:137182019-11-29T09:04:19Z http://journalarticle.ukm.my/13718/ Refractive index and sensing of glucose molarities determined using Au-Cr K-SPR at 670/785 nm wavelength P. Susthitha Menon, Mulyanti, Budi Nur Akmar Jamil, Wulandari, Chandra Nugroho, Harbi Setyo Gan, Siew Mei Noor Faizah Zainul Abidin, Hasanah, Lilik Pawinanto, Roer Eka Dilla Duryha Berhanuddin, In this paper, we determine the optical refractive indices of different molarities of glucose using nano-laminated gold/chromium (Au-Cr) thin film via Kretschmann-based Surface Plasmon Resonance (K-SPR) sensing with angular interrogation. The nano-laminated Au-Cr K-SPR sensor detects the glucose presence in low- and high-concentration of 4-12 mmol/L and 55-277 mmol/L, respectively, under the exposure of 670 nm and 785 nm optical wavelengths. The experimental results showed that the minimum limit of detection (LOD) of Au-Cr K-SPR is 4 mmol/L and the glucose sensor sensitivities are in average of 3.41 o/M and 2.73o/M at 670 nm and 785 nm optical wavelength, respectively. Stable sensitivity for each concentration also shown from the sensorgram results, indicates the stable performance of nano-laminated Au-Cr SPR sensor to detect glucose in the range from mmol/L up to dmol/L. Values of refractive indices for glucose molarities obtained are 1.33187 (4 mmol/L) and 1.3191 (4 mmol/L) at 670 and 785 nm wavelength, respectively. These RI values are beneficial for numerical simulation of glucose sensors using nano-laminated Au-Cr thin films which have been reported for the first time. The sensor can be eventually deployed in integrated photonic sensing devices comprising of multiple analyte detection for lab-on-chip (LoC) and point-of care (PoC) applications. Penerbit Universiti Kebangsaan Malaysia 2019-06 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/13718/1/13%20P.%20Susthitha%20Menon.pdf P. Susthitha Menon, and Mulyanti, Budi and Nur Akmar Jamil, and Wulandari, Chandra and Nugroho, Harbi Setyo and Gan, Siew Mei and Noor Faizah Zainul Abidin, and Hasanah, Lilik and Pawinanto, Roer Eka and Dilla Duryha Berhanuddin, (2019) Refractive index and sensing of glucose molarities determined using Au-Cr K-SPR at 670/785 nm wavelength. Sains Malaysiana, 48 (6). pp. 1259-1265. ISSN 0126-6039 http://www.ukm.my/jsm/malay_journals/jilid48bil6_2019/KandunganJilid48Bil6_2019.html
spellingShingle P. Susthitha Menon,
Mulyanti, Budi
Nur Akmar Jamil,
Wulandari, Chandra
Nugroho, Harbi Setyo
Gan, Siew Mei
Noor Faizah Zainul Abidin,
Hasanah, Lilik
Pawinanto, Roer Eka
Dilla Duryha Berhanuddin,
Refractive index and sensing of glucose molarities determined using Au-Cr K-SPR at 670/785 nm wavelength
title Refractive index and sensing of glucose molarities determined using Au-Cr K-SPR at 670/785 nm wavelength
title_full Refractive index and sensing of glucose molarities determined using Au-Cr K-SPR at 670/785 nm wavelength
title_fullStr Refractive index and sensing of glucose molarities determined using Au-Cr K-SPR at 670/785 nm wavelength
title_full_unstemmed Refractive index and sensing of glucose molarities determined using Au-Cr K-SPR at 670/785 nm wavelength
title_short Refractive index and sensing of glucose molarities determined using Au-Cr K-SPR at 670/785 nm wavelength
title_sort refractive index and sensing of glucose molarities determined using au-cr k-spr at 670/785 nm wavelength
url http://journalarticle.ukm.my/13718/
http://journalarticle.ukm.my/13718/
http://journalarticle.ukm.my/13718/1/13%20P.%20Susthitha%20Menon.pdf