Response of LiF:Mg,Cu,P TL detector simulated with Geant4

The Geant4 simulation code was developed to study the Hp(10) energy response of the LiF:Mg,Cu,P (TLD-100H). Initial study chose the simulation conditions similar to the work reported by Obryk et al. in year 2011, in which a TLD-100H chip without filter was used. The work went further to simulate the...

Full description

Bibliographic Details
Main Authors: Supian Samat, W. Priharti
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2017
Online Access:http://journalarticle.ukm.my/11152/
http://journalarticle.ukm.my/11152/1/18%20S.B%20Samat.pdf
_version_ 1848812632472027136
author Supian Samat,
W. Priharti,
author_facet Supian Samat,
W. Priharti,
author_sort Supian Samat,
building UKM Institutional Repository
collection Online Access
description The Geant4 simulation code was developed to study the Hp(10) energy response of the LiF:Mg,Cu,P (TLD-100H). Initial study chose the simulation conditions similar to the work reported by Obryk et al. in year 2011, in which a TLD-100H chip without filter was used. The work went further to simulate the Hp(10) results obtained experimentally at SSDL Malaysia. The experiment used a TLD-100H chip embedded in a TLD card and the card was enclosed in a badge complete with PTFE filter. Irradiation with eleven photon energies in the range of 24-1250 keV was applied. The simulation code therefore took into accounts the details of the badge (the materials type and the dimensions of the chip, the card, the badge and the filters) and the set-up of the experiment (the source distance and the energies). In comparison with Obryk’s work, the simulation code yielded the mean deviation of 0.59%. For the experimental work, the simulated Hp(10) curves obtained were quite similar and comparable and a mean deviation of 13.96% was obtained. As both 0.59% and 13.96% deviations are within the acceptable limit of ±25%, it was concluded that a satisfactory level of accuracy has been achieved by the developed simulation code and the selection materials and physics processes that have been adapted in the code were correct. Sources of uncertainty that has contributed to this deviation are discussed.
first_indexed 2025-11-15T00:05:23Z
format Article
id oai:generic.eprints.org:11152
institution Universiti Kebangasaan Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T00:05:23Z
publishDate 2017
publisher Penerbit Universiti Kebangsaan Malaysia
recordtype eprints
repository_type Digital Repository
spelling oai:generic.eprints.org:111522017-12-23T02:39:56Z http://journalarticle.ukm.my/11152/ Response of LiF:Mg,Cu,P TL detector simulated with Geant4 Supian Samat, W. Priharti, The Geant4 simulation code was developed to study the Hp(10) energy response of the LiF:Mg,Cu,P (TLD-100H). Initial study chose the simulation conditions similar to the work reported by Obryk et al. in year 2011, in which a TLD-100H chip without filter was used. The work went further to simulate the Hp(10) results obtained experimentally at SSDL Malaysia. The experiment used a TLD-100H chip embedded in a TLD card and the card was enclosed in a badge complete with PTFE filter. Irradiation with eleven photon energies in the range of 24-1250 keV was applied. The simulation code therefore took into accounts the details of the badge (the materials type and the dimensions of the chip, the card, the badge and the filters) and the set-up of the experiment (the source distance and the energies). In comparison with Obryk’s work, the simulation code yielded the mean deviation of 0.59%. For the experimental work, the simulated Hp(10) curves obtained were quite similar and comparable and a mean deviation of 13.96% was obtained. As both 0.59% and 13.96% deviations are within the acceptable limit of ±25%, it was concluded that a satisfactory level of accuracy has been achieved by the developed simulation code and the selection materials and physics processes that have been adapted in the code were correct. Sources of uncertainty that has contributed to this deviation are discussed. Penerbit Universiti Kebangsaan Malaysia 2017-08 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/11152/1/18%20S.B%20Samat.pdf Supian Samat, and W. Priharti, (2017) Response of LiF:Mg,Cu,P TL detector simulated with Geant4. Sains Malaysiana, 46 (8). pp. 1317-1322. ISSN 0126-6039 http://www.ukm.my/jsm/malay_journals/jilid46bil8_2017/KandunganJilid46Bil8_2017.html
spellingShingle Supian Samat,
W. Priharti,
Response of LiF:Mg,Cu,P TL detector simulated with Geant4
title Response of LiF:Mg,Cu,P TL detector simulated with Geant4
title_full Response of LiF:Mg,Cu,P TL detector simulated with Geant4
title_fullStr Response of LiF:Mg,Cu,P TL detector simulated with Geant4
title_full_unstemmed Response of LiF:Mg,Cu,P TL detector simulated with Geant4
title_short Response of LiF:Mg,Cu,P TL detector simulated with Geant4
title_sort response of lif:mg,cu,p tl detector simulated with geant4
url http://journalarticle.ukm.my/11152/
http://journalarticle.ukm.my/11152/
http://journalarticle.ukm.my/11152/1/18%20S.B%20Samat.pdf