Measuring enteric methane emissions from individual dairy cows during milking by detecting eructation peaks

Measurement of enteric methane emissions from cattle has gained interest given that cattle are a significant source of anthropogenic greenhouse gas emissions. Infrared gas analysers were used in this study to continuously measure concentration of methane every second and detect eructations when cows...

Full description

Bibliographic Details
Main Author: Hardan, Ali
Format: Thesis (University of Nottingham only)
Language:English
Published: 2024
Subjects:
Online Access:https://eprints.nottingham.ac.uk/77869/
_version_ 1848801030011092992
author Hardan, Ali
author_facet Hardan, Ali
author_sort Hardan, Ali
building Nottingham Research Data Repository
collection Online Access
description Measurement of enteric methane emissions from cattle has gained interest given that cattle are a significant source of anthropogenic greenhouse gas emissions. Infrared gas analysers were used in this study to continuously measure concentration of methane every second and detect eructations when cows were being milked in robotic milking stations. Most of the cows investigated were Holstein-Friesian cows, housed at the University of Nottingham Centre for Dairy Science Innovation (CDSI) and on 17 commercial farms in the UK. The time-series signal of methane concentration was analysed using peak analysis and signal processing techniques to identify eructation peaks. The study found a high correlation (r = 0.71) between methane emissions calculated from area under eructations (integral of peaks) and amplitude of eructations using peak analysis approaches. Measurements of methane emissions obtained using an SP Guardian analyser with low gas volume and slow flow rate provided the most repeatable measurements and detected more variation among cows than other gas analysers tested. Measurements of enteric methane using signal processing were estimated to be 0.38 (s.e. 0.01) g/min, 31.8 (s.e. 0.5) g/kg dry matter intake (DMI) and 25.6 (s.e. 0.5) g/kg milk across all 18 farms studied. During early lactation methane emissions increased to 0.4 g/min at week 10 of lactation, and then was steady until week 70. This profile was similar for emissions per unit feed intake. It is concluded that signal processing can be used with different gas analysers in a breath sampling approach to reliably extract methane measurements based on amplitude of detected eructation peaks.
first_indexed 2025-11-14T21:00:58Z
format Thesis (University of Nottingham only)
id nottingham-77869
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T21:00:58Z
publishDate 2024
recordtype eprints
repository_type Digital Repository
spelling nottingham-778692024-07-31T04:40:47Z https://eprints.nottingham.ac.uk/77869/ Measuring enteric methane emissions from individual dairy cows during milking by detecting eructation peaks Hardan, Ali Measurement of enteric methane emissions from cattle has gained interest given that cattle are a significant source of anthropogenic greenhouse gas emissions. Infrared gas analysers were used in this study to continuously measure concentration of methane every second and detect eructations when cows were being milked in robotic milking stations. Most of the cows investigated were Holstein-Friesian cows, housed at the University of Nottingham Centre for Dairy Science Innovation (CDSI) and on 17 commercial farms in the UK. The time-series signal of methane concentration was analysed using peak analysis and signal processing techniques to identify eructation peaks. The study found a high correlation (r = 0.71) between methane emissions calculated from area under eructations (integral of peaks) and amplitude of eructations using peak analysis approaches. Measurements of methane emissions obtained using an SP Guardian analyser with low gas volume and slow flow rate provided the most repeatable measurements and detected more variation among cows than other gas analysers tested. Measurements of enteric methane using signal processing were estimated to be 0.38 (s.e. 0.01) g/min, 31.8 (s.e. 0.5) g/kg dry matter intake (DMI) and 25.6 (s.e. 0.5) g/kg milk across all 18 farms studied. During early lactation methane emissions increased to 0.4 g/min at week 10 of lactation, and then was steady until week 70. This profile was similar for emissions per unit feed intake. It is concluded that signal processing can be used with different gas analysers in a breath sampling approach to reliably extract methane measurements based on amplitude of detected eructation peaks. 2024-07-31 Thesis (University of Nottingham only) NonPeerReviewed application/pdf en cc_by https://eprints.nottingham.ac.uk/77869/1/Final%20version%20thesis%20%20Ali%20Hardan%2024.pdf Hardan, Ali (2024) Measuring enteric methane emissions from individual dairy cows during milking by detecting eructation peaks. PhD thesis, University of Nottingham. enteric methane gas analyser dairy cows maximum peak amplitude
spellingShingle enteric methane
gas analyser
dairy cows
maximum peak amplitude
Hardan, Ali
Measuring enteric methane emissions from individual dairy cows during milking by detecting eructation peaks
title Measuring enteric methane emissions from individual dairy cows during milking by detecting eructation peaks
title_full Measuring enteric methane emissions from individual dairy cows during milking by detecting eructation peaks
title_fullStr Measuring enteric methane emissions from individual dairy cows during milking by detecting eructation peaks
title_full_unstemmed Measuring enteric methane emissions from individual dairy cows during milking by detecting eructation peaks
title_short Measuring enteric methane emissions from individual dairy cows during milking by detecting eructation peaks
title_sort measuring enteric methane emissions from individual dairy cows during milking by detecting eructation peaks
topic enteric methane
gas analyser
dairy cows
maximum peak amplitude
url https://eprints.nottingham.ac.uk/77869/