Control limitations of a cascaded H-bridge converter in solid-state substation applications

A substantial transition is underway in the present era, characterised by a growing adoption of electric vehicles (EVs) and the integration of additional renewable energy sources into the utility grid. This shift is necessary for mitigating greenhouse gas emissions and addressing the increasing ener...

Full description

Bibliographic Details
Main Author: Amara, Fatima
Format: Thesis (University of Nottingham only)
Language:English
Published: 2024
Subjects:
Online Access:https://eprints.nottingham.ac.uk/77429/
_version_ 1848800997807226880
author Amara, Fatima
author_facet Amara, Fatima
author_sort Amara, Fatima
building Nottingham Research Data Repository
collection Online Access
description A substantial transition is underway in the present era, characterised by a growing adoption of electric vehicles (EVs) and the integration of additional renewable energy sources into the utility grid. This shift is necessary for mitigating greenhouse gas emissions and addressing the increasing energy demand. Power electronics is a key facilitator in this transformation, mainly as the integration of small-scale renewable energy sources and EVs occurs at a low voltage DC level (LV) while the existing grid utility operates on an AC system. Consequently, there is an escalating demand for connecting various components to either low DC or AC voltage. An actual example of this integration is evident in the UNFLEX project, where diverse loads with varying voltage ratings are connected to each port, functioning as a power electronics-based transformer. This study concentrates explicitly on a single port of the UNIFLEX-PM converter linked to a low-voltage grid, where multilevel converters such as cascaded H-bridge converters are chosen. The integration of a single-phase CHB converter in the UNIFLEX-PM configuration simplifies the setup by eliminating the need for isolation through a DC/DC converter, a feature present in Dual Active Bridge (DAB) and DC/DC converters. In the proposed setup, each DC-link of the CHB is connected to uneven loads, operating consistently at a specific power level. However, to fully use the flexibility of power exchange within this system, the converter can interface with various bidirectional power loads. This results in the establishment of a localised grid that serves as a low-bus voltage connection to the grid. This adjustment facilitates the generation of diverse power levels based on the direction taken through each H-bridge of the CHB converter. Appropriate control measures have been suggested to guarantee the CHB converter operates effectively, which are verified using mathematical modelling, simulation verification and hardware-in-the-loop testing.
first_indexed 2025-11-14T21:00:27Z
format Thesis (University of Nottingham only)
id nottingham-77429
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T21:00:27Z
publishDate 2024
recordtype eprints
repository_type Digital Repository
spelling nottingham-774292025-02-28T15:20:07Z https://eprints.nottingham.ac.uk/77429/ Control limitations of a cascaded H-bridge converter in solid-state substation applications Amara, Fatima A substantial transition is underway in the present era, characterised by a growing adoption of electric vehicles (EVs) and the integration of additional renewable energy sources into the utility grid. This shift is necessary for mitigating greenhouse gas emissions and addressing the increasing energy demand. Power electronics is a key facilitator in this transformation, mainly as the integration of small-scale renewable energy sources and EVs occurs at a low voltage DC level (LV) while the existing grid utility operates on an AC system. Consequently, there is an escalating demand for connecting various components to either low DC or AC voltage. An actual example of this integration is evident in the UNFLEX project, where diverse loads with varying voltage ratings are connected to each port, functioning as a power electronics-based transformer. This study concentrates explicitly on a single port of the UNIFLEX-PM converter linked to a low-voltage grid, where multilevel converters such as cascaded H-bridge converters are chosen. The integration of a single-phase CHB converter in the UNIFLEX-PM configuration simplifies the setup by eliminating the need for isolation through a DC/DC converter, a feature present in Dual Active Bridge (DAB) and DC/DC converters. In the proposed setup, each DC-link of the CHB is connected to uneven loads, operating consistently at a specific power level. However, to fully use the flexibility of power exchange within this system, the converter can interface with various bidirectional power loads. This results in the establishment of a localised grid that serves as a low-bus voltage connection to the grid. This adjustment facilitates the generation of diverse power levels based on the direction taken through each H-bridge of the CHB converter. Appropriate control measures have been suggested to guarantee the CHB converter operates effectively, which are verified using mathematical modelling, simulation verification and hardware-in-the-loop testing. 2024-07-18 Thesis (University of Nottingham only) NonPeerReviewed application/pdf en cc_by https://eprints.nottingham.ac.uk/77429/1/Amara%20Fatima%2014341833_Correction.pdf Amara, Fatima (2024) Control limitations of a cascaded H-bridge converter in solid-state substation applications. PhD thesis, University of Nottingham. Power electronics; Multilevel converters; UNIFLEX-PM converter
spellingShingle Power electronics; Multilevel converters; UNIFLEX-PM converter
Amara, Fatima
Control limitations of a cascaded H-bridge converter in solid-state substation applications
title Control limitations of a cascaded H-bridge converter in solid-state substation applications
title_full Control limitations of a cascaded H-bridge converter in solid-state substation applications
title_fullStr Control limitations of a cascaded H-bridge converter in solid-state substation applications
title_full_unstemmed Control limitations of a cascaded H-bridge converter in solid-state substation applications
title_short Control limitations of a cascaded H-bridge converter in solid-state substation applications
title_sort control limitations of a cascaded h-bridge converter in solid-state substation applications
topic Power electronics; Multilevel converters; UNIFLEX-PM converter
url https://eprints.nottingham.ac.uk/77429/