Optimal H2 control design of active front-end integrating grid model identification

Small-signal stability and dynamic performance are of great concern for AC power grids with high penetration of power converters. The interactions between these converters may lead to performance degradation or even system instability and failure at certain conditions. To deal with such problems, gl...

Full description

Bibliographic Details
Main Author: Li, Kang
Format: Thesis (University of Nottingham only)
Language:English
Published: 2021
Subjects:
Online Access:https://eprints.nottingham.ac.uk/66039/
_version_ 1848800290218704896
author Li, Kang
author_facet Li, Kang
author_sort Li, Kang
building Nottingham Research Data Repository
collection Online Access
description Small-signal stability and dynamic performance are of great concern for AC power grids with high penetration of power converters. The interactions between these converters may lead to performance degradation or even system instability and failure at certain conditions. To deal with such problems, global modelling and integrated control are proposed. However, because of the highly integration of power grids in commercial industry environment, the lack of information about parameters and methods of the embedded converters, impedes the development of global models for system analysis and control design. To fill the gap, this research investigated the utility of system identification techniques to estimate a state space model of the unknown power grid, and proposed an approach to incorporate it into the design of local converters. Hence interactions between the grid and the to be designed converters could be taken into account and issues mitigated. Specifically in this research, the proposed method is applied to the control design of a grid-connected active front end (AFE). In a notional system, a voltage source inverter (VSI) is included to emulate the unknown grid and supplies power to an AFE feeding a constant power load (CPL). Firstly, a state space model of the grid is identified through perturbation and response test at the point of common coupling (PCC) in a specially designed experiment. It is then combined with the open loop model of the AFE to build a global model of the grid-AFE system. The plant for the control design will then be not only represented by the AFE's dynamics, but will also include that of the identified grid at the PCC. Implementation of the identification experiment involved and mathematical manipulations used to merge the two subsystem models are presented in detail. The global model is utilized to synthesize a state feedback controller, denoted as `optimal $H_2$ controller' in this thesis for the AFE by the use of a structured $H_2$ algorithm, which optimizes the dynamic performance of AFE while intrinsically ensuring stability of the grid-AFE system. Effectiveness and advantages of the proposed control design method is validated by simulations and experiments. The grid-AFE system performance when the AFE adopts the optimal $H_2$ controller or best-tuned proportional-integral (PI) controllers is compared. The use of optimal $H_2$ controller outperforms with faster dynamic response and greater stability margin the PI based solution. Scalability of the proposed method in more complex power grids and its robustness against system parameters drifting are also discussed.
first_indexed 2025-11-14T20:49:12Z
format Thesis (University of Nottingham only)
id nottingham-66039
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T20:49:12Z
publishDate 2021
recordtype eprints
repository_type Digital Repository
spelling nottingham-660392022-01-14T08:35:09Z https://eprints.nottingham.ac.uk/66039/ Optimal H2 control design of active front-end integrating grid model identification Li, Kang Small-signal stability and dynamic performance are of great concern for AC power grids with high penetration of power converters. The interactions between these converters may lead to performance degradation or even system instability and failure at certain conditions. To deal with such problems, global modelling and integrated control are proposed. However, because of the highly integration of power grids in commercial industry environment, the lack of information about parameters and methods of the embedded converters, impedes the development of global models for system analysis and control design. To fill the gap, this research investigated the utility of system identification techniques to estimate a state space model of the unknown power grid, and proposed an approach to incorporate it into the design of local converters. Hence interactions between the grid and the to be designed converters could be taken into account and issues mitigated. Specifically in this research, the proposed method is applied to the control design of a grid-connected active front end (AFE). In a notional system, a voltage source inverter (VSI) is included to emulate the unknown grid and supplies power to an AFE feeding a constant power load (CPL). Firstly, a state space model of the grid is identified through perturbation and response test at the point of common coupling (PCC) in a specially designed experiment. It is then combined with the open loop model of the AFE to build a global model of the grid-AFE system. The plant for the control design will then be not only represented by the AFE's dynamics, but will also include that of the identified grid at the PCC. Implementation of the identification experiment involved and mathematical manipulations used to merge the two subsystem models are presented in detail. The global model is utilized to synthesize a state feedback controller, denoted as `optimal $H_2$ controller' in this thesis for the AFE by the use of a structured $H_2$ algorithm, which optimizes the dynamic performance of AFE while intrinsically ensuring stability of the grid-AFE system. Effectiveness and advantages of the proposed control design method is validated by simulations and experiments. The grid-AFE system performance when the AFE adopts the optimal $H_2$ controller or best-tuned proportional-integral (PI) controllers is compared. The use of optimal $H_2$ controller outperforms with faster dynamic response and greater stability margin the PI based solution. Scalability of the proposed method in more complex power grids and its robustness against system parameters drifting are also discussed. 2021-10-15 Thesis (University of Nottingham only) NonPeerReviewed application/pdf en cc_by https://eprints.nottingham.ac.uk/66039/1/thesis.pdf Li, Kang (2021) Optimal H2 control design of active front-end integrating grid model identification. PhD thesis, University of Nottingham. AC-DC converter control H2 control Grid identification
spellingShingle AC-DC converter control
H2 control
Grid identification
Li, Kang
Optimal H2 control design of active front-end integrating grid model identification
title Optimal H2 control design of active front-end integrating grid model identification
title_full Optimal H2 control design of active front-end integrating grid model identification
title_fullStr Optimal H2 control design of active front-end integrating grid model identification
title_full_unstemmed Optimal H2 control design of active front-end integrating grid model identification
title_short Optimal H2 control design of active front-end integrating grid model identification
title_sort optimal h2 control design of active front-end integrating grid model identification
topic AC-DC converter control
H2 control
Grid identification
url https://eprints.nottingham.ac.uk/66039/