Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application

Electric variable speed drives (VSDs) based on two VSDs connected to a multiphase machine are an attractive solution to replace high-power mechanic and hydraulic systems in many sectors of industry and transportation because they present high performance with reduced cost, volume and weight. Among t...

Full description

Bibliographic Details
Main Authors: Alcaide, Abraham Marquez, Wang, Xuchen, Yan, Hao, Leon, Jose I., Monopoli, Vito Giuseppe, Buticchi, Giampaolo, Vazquez, Sergio, Liserre, Marco, Franquelo, Leopoldo G.
Format: Article
Language:English
Published: Institute of Electrical and Electronics Engineers Inc. 2021
Subjects:
Online Access:https://eprints.nottingham.ac.uk/65340/
_version_ 1848800212477280256
author Alcaide, Abraham Marquez
Wang, Xuchen
Yan, Hao
Leon, Jose I.
Monopoli, Vito Giuseppe
Buticchi, Giampaolo
Vazquez, Sergio
Liserre, Marco
Franquelo, Leopoldo G.
author_facet Alcaide, Abraham Marquez
Wang, Xuchen
Yan, Hao
Leon, Jose I.
Monopoli, Vito Giuseppe
Buticchi, Giampaolo
Vazquez, Sergio
Liserre, Marco
Franquelo, Leopoldo G.
author_sort Alcaide, Abraham Marquez
building Nottingham Research Data Repository
collection Online Access
description Electric variable speed drives (VSDs) based on two VSDs connected to a multiphase machine are an attractive solution to replace high-power mechanic and hydraulic systems in many sectors of industry and transportation because they present high performance with reduced cost, volume and weight. Among the causes which affect the reliability of dual VSDs, the common-mode current flowing through the machine bearing is an important issue. This paper faces the mitigation of the common-mode current by reducing the common-mode voltage (CMV) generated by the operation of a dual VSD. The CMV reduction is carried out without introducing any extra device and/or passive filtering method. This CMV reduction is performed by applying a specific phase-displacement between the modulation strategies of each single inverter drive. The proposed technique has been evaluated in a down scaled experimental setup in order to test its effectiveness
first_indexed 2025-11-14T20:47:58Z
format Article
id nottingham-65340
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T20:47:58Z
publishDate 2021
publisher Institute of Electrical and Electronics Engineers Inc.
recordtype eprints
repository_type Digital Repository
spelling nottingham-653402023-05-25T08:12:32Z https://eprints.nottingham.ac.uk/65340/ Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application Alcaide, Abraham Marquez Wang, Xuchen Yan, Hao Leon, Jose I. Monopoli, Vito Giuseppe Buticchi, Giampaolo Vazquez, Sergio Liserre, Marco Franquelo, Leopoldo G. Electric variable speed drives (VSDs) based on two VSDs connected to a multiphase machine are an attractive solution to replace high-power mechanic and hydraulic systems in many sectors of industry and transportation because they present high performance with reduced cost, volume and weight. Among the causes which affect the reliability of dual VSDs, the common-mode current flowing through the machine bearing is an important issue. This paper faces the mitigation of the common-mode current by reducing the common-mode voltage (CMV) generated by the operation of a dual VSD. The CMV reduction is carried out without introducing any extra device and/or passive filtering method. This CMV reduction is performed by applying a specific phase-displacement between the modulation strategies of each single inverter drive. The proposed technique has been evaluated in a down scaled experimental setup in order to test its effectiveness Institute of Electrical and Electronics Engineers Inc. 2021-04-13 Article PeerReviewed application/pdf en cc_by https://eprints.nottingham.ac.uk/65340/1/Alcaide-2021-Common-mode-voltage-mitigation-of-d.pdf Alcaide, Abraham Marquez, Wang, Xuchen, Yan, Hao, Leon, Jose I., Monopoli, Vito Giuseppe, Buticchi, Giampaolo, Vazquez, Sergio, Liserre, Marco and Franquelo, Leopoldo G. (2021) Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application. IEEE Access, 9 . pp. 67477-67487. ISSN 2169-3536 Harmonic analysis; Pulse width modulation; Common-mode voltage http://dx.doi.org/10.1109/ACCESS.2021.3072967 doi:10.1109/ACCESS.2021.3072967 doi:10.1109/ACCESS.2021.3072967
spellingShingle Harmonic analysis; Pulse width modulation; Common-mode voltage
Alcaide, Abraham Marquez
Wang, Xuchen
Yan, Hao
Leon, Jose I.
Monopoli, Vito Giuseppe
Buticchi, Giampaolo
Vazquez, Sergio
Liserre, Marco
Franquelo, Leopoldo G.
Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application
title Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application
title_full Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application
title_fullStr Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application
title_full_unstemmed Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application
title_short Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application
title_sort common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application
topic Harmonic analysis; Pulse width modulation; Common-mode voltage
url https://eprints.nottingham.ac.uk/65340/
https://eprints.nottingham.ac.uk/65340/
https://eprints.nottingham.ac.uk/65340/