Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application
Electric variable speed drives (VSDs) based on two VSDs connected to a multiphase machine are an attractive solution to replace high-power mechanic and hydraulic systems in many sectors of industry and transportation because they present high performance with reduced cost, volume and weight. Among t...
| Main Authors: | , , , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Institute of Electrical and Electronics Engineers Inc.
2021
|
| Subjects: | |
| Online Access: | https://eprints.nottingham.ac.uk/65340/ |
| _version_ | 1848800212477280256 |
|---|---|
| author | Alcaide, Abraham Marquez Wang, Xuchen Yan, Hao Leon, Jose I. Monopoli, Vito Giuseppe Buticchi, Giampaolo Vazquez, Sergio Liserre, Marco Franquelo, Leopoldo G. |
| author_facet | Alcaide, Abraham Marquez Wang, Xuchen Yan, Hao Leon, Jose I. Monopoli, Vito Giuseppe Buticchi, Giampaolo Vazquez, Sergio Liserre, Marco Franquelo, Leopoldo G. |
| author_sort | Alcaide, Abraham Marquez |
| building | Nottingham Research Data Repository |
| collection | Online Access |
| description | Electric variable speed drives (VSDs) based on two VSDs connected to a multiphase machine are an attractive solution to replace high-power mechanic and hydraulic systems in many sectors of industry and transportation because they present high performance with reduced cost, volume and weight. Among the causes which affect the reliability of dual VSDs, the common-mode current flowing through the machine bearing is an important issue. This paper faces the mitigation of the common-mode current by reducing the common-mode voltage (CMV) generated by the operation of a dual VSD. The CMV reduction is carried out without introducing any extra device and/or passive filtering method. This CMV reduction is performed by applying a specific phase-displacement between the modulation strategies of each single inverter drive. The proposed technique has been evaluated in a down scaled experimental setup in order to test its effectiveness |
| first_indexed | 2025-11-14T20:47:58Z |
| format | Article |
| id | nottingham-65340 |
| institution | University of Nottingham Malaysia Campus |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-14T20:47:58Z |
| publishDate | 2021 |
| publisher | Institute of Electrical and Electronics Engineers Inc. |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | nottingham-653402023-05-25T08:12:32Z https://eprints.nottingham.ac.uk/65340/ Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application Alcaide, Abraham Marquez Wang, Xuchen Yan, Hao Leon, Jose I. Monopoli, Vito Giuseppe Buticchi, Giampaolo Vazquez, Sergio Liserre, Marco Franquelo, Leopoldo G. Electric variable speed drives (VSDs) based on two VSDs connected to a multiphase machine are an attractive solution to replace high-power mechanic and hydraulic systems in many sectors of industry and transportation because they present high performance with reduced cost, volume and weight. Among the causes which affect the reliability of dual VSDs, the common-mode current flowing through the machine bearing is an important issue. This paper faces the mitigation of the common-mode current by reducing the common-mode voltage (CMV) generated by the operation of a dual VSD. The CMV reduction is carried out without introducing any extra device and/or passive filtering method. This CMV reduction is performed by applying a specific phase-displacement between the modulation strategies of each single inverter drive. The proposed technique has been evaluated in a down scaled experimental setup in order to test its effectiveness Institute of Electrical and Electronics Engineers Inc. 2021-04-13 Article PeerReviewed application/pdf en cc_by https://eprints.nottingham.ac.uk/65340/1/Alcaide-2021-Common-mode-voltage-mitigation-of-d.pdf Alcaide, Abraham Marquez, Wang, Xuchen, Yan, Hao, Leon, Jose I., Monopoli, Vito Giuseppe, Buticchi, Giampaolo, Vazquez, Sergio, Liserre, Marco and Franquelo, Leopoldo G. (2021) Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application. IEEE Access, 9 . pp. 67477-67487. ISSN 2169-3536 Harmonic analysis; Pulse width modulation; Common-mode voltage http://dx.doi.org/10.1109/ACCESS.2021.3072967 doi:10.1109/ACCESS.2021.3072967 doi:10.1109/ACCESS.2021.3072967 |
| spellingShingle | Harmonic analysis; Pulse width modulation; Common-mode voltage Alcaide, Abraham Marquez Wang, Xuchen Yan, Hao Leon, Jose I. Monopoli, Vito Giuseppe Buticchi, Giampaolo Vazquez, Sergio Liserre, Marco Franquelo, Leopoldo G. Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application |
| title | Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application |
| title_full | Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application |
| title_fullStr | Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application |
| title_full_unstemmed | Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application |
| title_short | Common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application |
| title_sort | common-mode voltage mitigation of dual three-phase voltage source inverters in a motor drive application |
| topic | Harmonic analysis; Pulse width modulation; Common-mode voltage |
| url | https://eprints.nottingham.ac.uk/65340/ https://eprints.nottingham.ac.uk/65340/ https://eprints.nottingham.ac.uk/65340/ |