Post-occupancy evaluation of indoor air quality and thermal performance in a zero carbon building

Maintaining a comfortable indoor environment throughout the year makes up the main part of energy consumption caused by people’s use of buildings. In recent years, China has started to integrate sustainable technologies into green building design and construction. However, some post-occupancy report...

Full description

Bibliographic Details
Main Authors: Trofimova, Polina, Cheshmehzangi, Ali, Deng, Wu, Hancock, Craig
Format: Article
Language:English
Published: MDPI AG 2021
Subjects:
Online Access:https://eprints.nottingham.ac.uk/64725/
_version_ 1848800158153703424
author Trofimova, Polina
Cheshmehzangi, Ali
Deng, Wu
Hancock, Craig
author_facet Trofimova, Polina
Cheshmehzangi, Ali
Deng, Wu
Hancock, Craig
author_sort Trofimova, Polina
building Nottingham Research Data Repository
collection Online Access
description Maintaining a comfortable indoor environment throughout the year makes up the main part of energy consumption caused by people’s use of buildings. In recent years, China has started to integrate sustainable technologies into green building design and construction. However, some post-occupancy reports on certified buildings revealed that such integration has been perceived to prioritize energy savings over comfort. This paper aims to investigate the ability of the first Chinese zero carbon building to maintain comfortable and healthy indoor conditions in the summer season. The research implements a combination of occupant survey and on-site measurements to evaluate the occupants’ perception of the indoor environment quality (IEQ) and benchmark the measurements against relevant standards. The results from this study show that the mean summer indoor temperature was 0.9 °C above the standard limit, while on average, occupants gave a positive score to the indoor thermal environment. High contentment with the building acoustics was reported by users and supported by sensors measurements meeting the standard values. The illuminance levels were mainly maintained high with the exception of the light in one of the studied zones. Analyzing the data on occupants experiencing sick building syndromes revealed that 45.8% of respondents experienced at least one of the symptoms.
first_indexed 2025-11-14T20:47:06Z
format Article
id nottingham-64725
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T20:47:06Z
publishDate 2021
publisher MDPI AG
recordtype eprints
repository_type Digital Repository
spelling nottingham-647252021-03-10T06:31:41Z https://eprints.nottingham.ac.uk/64725/ Post-occupancy evaluation of indoor air quality and thermal performance in a zero carbon building Trofimova, Polina Cheshmehzangi, Ali Deng, Wu Hancock, Craig Maintaining a comfortable indoor environment throughout the year makes up the main part of energy consumption caused by people’s use of buildings. In recent years, China has started to integrate sustainable technologies into green building design and construction. However, some post-occupancy reports on certified buildings revealed that such integration has been perceived to prioritize energy savings over comfort. This paper aims to investigate the ability of the first Chinese zero carbon building to maintain comfortable and healthy indoor conditions in the summer season. The research implements a combination of occupant survey and on-site measurements to evaluate the occupants’ perception of the indoor environment quality (IEQ) and benchmark the measurements against relevant standards. The results from this study show that the mean summer indoor temperature was 0.9 °C above the standard limit, while on average, occupants gave a positive score to the indoor thermal environment. High contentment with the building acoustics was reported by users and supported by sensors measurements meeting the standard values. The illuminance levels were mainly maintained high with the exception of the light in one of the studied zones. Analyzing the data on occupants experiencing sick building syndromes revealed that 45.8% of respondents experienced at least one of the symptoms. MDPI AG 2021-01-12 Article PeerReviewed application/pdf en cc_by https://eprints.nottingham.ac.uk/64725/1/Post-occupancy%20evaluation%20of%20indoor%20air%20quality%20and%20thermal%20performance%20in%20a%20zero%20carbon%20building.pdf Trofimova, Polina, Cheshmehzangi, Ali, Deng, Wu and Hancock, Craig (2021) Post-occupancy evaluation of indoor air quality and thermal performance in a zero carbon building. Sustainability, 13 (2). p. 667. ISSN 2071-1050 IEQ; sustainable building; indoor environment; health http://dx.doi.org/10.3390/su13020667 doi:10.3390/su13020667 doi:10.3390/su13020667
spellingShingle IEQ; sustainable building; indoor environment; health
Trofimova, Polina
Cheshmehzangi, Ali
Deng, Wu
Hancock, Craig
Post-occupancy evaluation of indoor air quality and thermal performance in a zero carbon building
title Post-occupancy evaluation of indoor air quality and thermal performance in a zero carbon building
title_full Post-occupancy evaluation of indoor air quality and thermal performance in a zero carbon building
title_fullStr Post-occupancy evaluation of indoor air quality and thermal performance in a zero carbon building
title_full_unstemmed Post-occupancy evaluation of indoor air quality and thermal performance in a zero carbon building
title_short Post-occupancy evaluation of indoor air quality and thermal performance in a zero carbon building
title_sort post-occupancy evaluation of indoor air quality and thermal performance in a zero carbon building
topic IEQ; sustainable building; indoor environment; health
url https://eprints.nottingham.ac.uk/64725/
https://eprints.nottingham.ac.uk/64725/
https://eprints.nottingham.ac.uk/64725/