Low-rise office retrofit: prerequisite for sustainable and green buildings in Shanghai

Commercial buildings comprise of 25% office blocks, largest proportion in commercial sector with highest energy consumption in Shanghai. Nevertheless, the demand for office space is still rising, driven by state-owned enterprises. Unfortunately, these existing buildings are energy inefficient as the...

Full description

Bibliographic Details
Main Authors: Hong, Y., Deng, W., Ezeh, Collins I.
Format: Conference or Workshop Item
Language:English
Published: 2019
Online Access:https://eprints.nottingham.ac.uk/57142/
_version_ 1848799439446081536
author Hong, Y.
Deng, W.
Ezeh, Collins I.
author_facet Hong, Y.
Deng, W.
Ezeh, Collins I.
author_sort Hong, Y.
building Nottingham Research Data Repository
collection Online Access
description Commercial buildings comprise of 25% office blocks, largest proportion in commercial sector with highest energy consumption in Shanghai. Nevertheless, the demand for office space is still rising, driven by state-owned enterprises. Unfortunately, these existing buildings are energy inefficient as they barely adapt to present varying climate conditions of the province. Owing to aggravated climate change and rising urbanization rate of Shanghai, attention should be directed towards upgrade of office buildings to meet set sustainable building standards. 3-dimensional spatial characterization using vector topographic mapping posits low-rise buildings account for more than 50% of total buildings in Shanghai. Hence, retrofitting existing low-rise office buildings will significantly contribute to building sustainability. Subsequently, a retrofit package guideline suitable for sporadic energy use mode in rapidly expanding cities like Shanghai should be established. This nascent study postulates an updated correlation between climate change and building energy consumption in Shanghai. Based on the postulation, it is recommended that the best energy conserving building retrofit package is that which can mitigate the impact of both societal factors (like urbanization rate) and climate change to building energy consumption. In general, this study defines a foundation framework for building researchers and decision-makers to effectively evaluate retrofit measures for existing buildings become sustainability in Shanghai.
first_indexed 2025-11-14T20:35:41Z
format Conference or Workshop Item
id nottingham-57142
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T20:35:41Z
publishDate 2019
recordtype eprints
repository_type Digital Repository
spelling nottingham-571422019-07-29T11:13:44Z https://eprints.nottingham.ac.uk/57142/ Low-rise office retrofit: prerequisite for sustainable and green buildings in Shanghai Hong, Y. Deng, W. Ezeh, Collins I. Commercial buildings comprise of 25% office blocks, largest proportion in commercial sector with highest energy consumption in Shanghai. Nevertheless, the demand for office space is still rising, driven by state-owned enterprises. Unfortunately, these existing buildings are energy inefficient as they barely adapt to present varying climate conditions of the province. Owing to aggravated climate change and rising urbanization rate of Shanghai, attention should be directed towards upgrade of office buildings to meet set sustainable building standards. 3-dimensional spatial characterization using vector topographic mapping posits low-rise buildings account for more than 50% of total buildings in Shanghai. Hence, retrofitting existing low-rise office buildings will significantly contribute to building sustainability. Subsequently, a retrofit package guideline suitable for sporadic energy use mode in rapidly expanding cities like Shanghai should be established. This nascent study postulates an updated correlation between climate change and building energy consumption in Shanghai. Based on the postulation, it is recommended that the best energy conserving building retrofit package is that which can mitigate the impact of both societal factors (like urbanization rate) and climate change to building energy consumption. In general, this study defines a foundation framework for building researchers and decision-makers to effectively evaluate retrofit measures for existing buildings become sustainability in Shanghai. 2019-06-03 Conference or Workshop Item PeerReviewed application/pdf en cc_by https://eprints.nottingham.ac.uk/57142/1/Hong_2019_IOP_Conf._Ser.__Earth_Environ._Sci._281_012025.pdf Hong, Y., Deng, W. and Ezeh, Collins I. (2019) Low-rise office retrofit: prerequisite for sustainable and green buildings in Shanghai. In: 3rd International Conference on Environmental and Energy Engineering, IC3E 2019, 14-16 March 2019, Shanghai, China. http://dx.doi.org/10.1088/1755-1315/281/1/012025 10.1088/1755-1315/281/1/012025 10.1088/1755-1315/281/1/012025 10.1088/1755-1315/281/1/012025
spellingShingle Hong, Y.
Deng, W.
Ezeh, Collins I.
Low-rise office retrofit: prerequisite for sustainable and green buildings in Shanghai
title Low-rise office retrofit: prerequisite for sustainable and green buildings in Shanghai
title_full Low-rise office retrofit: prerequisite for sustainable and green buildings in Shanghai
title_fullStr Low-rise office retrofit: prerequisite for sustainable and green buildings in Shanghai
title_full_unstemmed Low-rise office retrofit: prerequisite for sustainable and green buildings in Shanghai
title_short Low-rise office retrofit: prerequisite for sustainable and green buildings in Shanghai
title_sort low-rise office retrofit: prerequisite for sustainable and green buildings in shanghai
url https://eprints.nottingham.ac.uk/57142/
https://eprints.nottingham.ac.uk/57142/
https://eprints.nottingham.ac.uk/57142/