Wearable magnetoencephalography

Functional neuroimaging offers a means to understand brain function and dysfunction. Over decades, different technologies have been developed to provide a non-invasive measure of brain activity that could help us to better understand the mechanisms underlying human cognition. Magnetoencephalography...

Full description

Bibliographic Details
Main Author: Boto, Elena
Format: Thesis (University of Nottingham only)
Language:English
Published: 2019
Subjects:
Online Access:https://eprints.nottingham.ac.uk/56508/
_version_ 1848799339496865792
author Boto, Elena
author_facet Boto, Elena
author_sort Boto, Elena
building Nottingham Research Data Repository
collection Online Access
description Functional neuroimaging offers a means to understand brain function and dysfunction. Over decades, different technologies have been developed to provide a non-invasive measure of brain activity that could help us to better understand the mechanisms underlying human cognition. Magnetoencephalography (MEG) is one of these techniques which, over the past 30 years, has been increasingly contributing to neuroscientific studies giving insights into human brain electrophysiology, with excellent temporal resolution and surprisingly high spatial resolution. However, MEG hardware has limitations and it has only been in the past few years that alternative technologies have seen a rapid progress with an intent to overcome the drawbacks of conventional MEG devices. The main limitation of MEG systems is that they rely on superconducting quantum interference devices (SQUIDs) to measure magnetic fields outside the head. This means that they require cryogenic cooling and as a consequence, sensors are fixed in position in a one-size-fits-all helmet. A vacuum is maintained between the subject’s head and the detectors which limits the sensitivity of the measurement, and subjects must remain still in large cumbersome scanners. Advances in the field of quantum technologies mean that magnetic field sensors, such as optically-pumped magnetometers (OPMs), operating at room temperature, are now able to achieve sensitivities similar to that of SQUIDs. This means that room temperature magnetoencephalography (MEG), with a greatly increased flexibility of sensor placement, can now be considered. Furthermore, these new sensors can be placed directly on the scalp surface giving, theoretically, a large increase in the magnitude of the measured signal. In this thesis, we explore the advantages of multi-channel OPM systems using both simulations, and experimental measurements made using commercially available OPMs in combination with a 3D-printed helmet. With the incorporation of field-nulling technologies, we demonstrate a non-restrictive MEG system that could benefit many different participant cohorts, for example children. The results presented highlight the opportunity afforded by OPMs to generate uncooled, potentially low-cost, high sensitivity MEG systems which offer a step change compared to the current generation of cryogenic instrumentation.
first_indexed 2025-11-14T20:34:06Z
format Thesis (University of Nottingham only)
id nottingham-56508
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T20:34:06Z
publishDate 2019
recordtype eprints
repository_type Digital Repository
spelling nottingham-565082025-02-28T14:29:05Z https://eprints.nottingham.ac.uk/56508/ Wearable magnetoencephalography Boto, Elena Functional neuroimaging offers a means to understand brain function and dysfunction. Over decades, different technologies have been developed to provide a non-invasive measure of brain activity that could help us to better understand the mechanisms underlying human cognition. Magnetoencephalography (MEG) is one of these techniques which, over the past 30 years, has been increasingly contributing to neuroscientific studies giving insights into human brain electrophysiology, with excellent temporal resolution and surprisingly high spatial resolution. However, MEG hardware has limitations and it has only been in the past few years that alternative technologies have seen a rapid progress with an intent to overcome the drawbacks of conventional MEG devices. The main limitation of MEG systems is that they rely on superconducting quantum interference devices (SQUIDs) to measure magnetic fields outside the head. This means that they require cryogenic cooling and as a consequence, sensors are fixed in position in a one-size-fits-all helmet. A vacuum is maintained between the subject’s head and the detectors which limits the sensitivity of the measurement, and subjects must remain still in large cumbersome scanners. Advances in the field of quantum technologies mean that magnetic field sensors, such as optically-pumped magnetometers (OPMs), operating at room temperature, are now able to achieve sensitivities similar to that of SQUIDs. This means that room temperature magnetoencephalography (MEG), with a greatly increased flexibility of sensor placement, can now be considered. Furthermore, these new sensors can be placed directly on the scalp surface giving, theoretically, a large increase in the magnitude of the measured signal. In this thesis, we explore the advantages of multi-channel OPM systems using both simulations, and experimental measurements made using commercially available OPMs in combination with a 3D-printed helmet. With the incorporation of field-nulling technologies, we demonstrate a non-restrictive MEG system that could benefit many different participant cohorts, for example children. The results presented highlight the opportunity afforded by OPMs to generate uncooled, potentially low-cost, high sensitivity MEG systems which offer a step change compared to the current generation of cryogenic instrumentation. 2019-07-17 Thesis (University of Nottingham only) NonPeerReviewed application/pdf en arr https://eprints.nottingham.ac.uk/56508/1/4244944_phd_thesis_elena_boto.pdf Boto, Elena (2019) Wearable magnetoencephalography. PhD thesis, University of Nottingham. Magnetoencephalography; MEG; Optically-pumped magnetometers; Wearable functional neuroimaging
spellingShingle Magnetoencephalography; MEG; Optically-pumped magnetometers; Wearable functional neuroimaging
Boto, Elena
Wearable magnetoencephalography
title Wearable magnetoencephalography
title_full Wearable magnetoencephalography
title_fullStr Wearable magnetoencephalography
title_full_unstemmed Wearable magnetoencephalography
title_short Wearable magnetoencephalography
title_sort wearable magnetoencephalography
topic Magnetoencephalography; MEG; Optically-pumped magnetometers; Wearable functional neuroimaging
url https://eprints.nottingham.ac.uk/56508/