Limits, stability and disturbance rejection analysis of voltage control loop strategies for grid forming converters in DC and AC microgrids with high penetration of constant power loads
This paper extensively analyzes the operation limits, system stability and disturbance rejection capability of the voltage control loops used in master-slave AC and DC Microgrids (MGs). Two different control schemes are studied analytically, simulated and experimentally tested, focusing on Constant...
| Main Authors: | , , , |
|---|---|
| Format: | Conference or Workshop Item |
| Language: | English |
| Published: |
2017
|
| Subjects: | |
| Online Access: | https://eprints.nottingham.ac.uk/50508/ |
| _version_ | 1848798269695590400 |
|---|---|
| author | Navarro-Rodríguez, Ángel Garcia, Pablo Cano, J.M. Sumner, M. |
| author_facet | Navarro-Rodríguez, Ángel Garcia, Pablo Cano, J.M. Sumner, M. |
| author_sort | Navarro-Rodríguez, Ángel |
| building | Nottingham Research Data Repository |
| collection | Online Access |
| description | This paper extensively analyzes the operation limits, system stability and disturbance rejection capability
of the voltage control loops used in master-slave AC and DC Microgrids (MGs). Two different control schemes are studied analytically, simulated and experimentally tested, focusing on Constant Power Loads (CPL). Additionally, the use of the virtual capacitance (VC) as a tool for response enhancement is introduced. The study pursues the proper selection of the controllers gains and minimization of capacitance values by considering the dynamic behavior. |
| first_indexed | 2025-11-14T20:17:05Z |
| format | Conference or Workshop Item |
| id | nottingham-50508 |
| institution | University of Nottingham Malaysia Campus |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-14T20:17:05Z |
| publishDate | 2017 |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | nottingham-505082020-05-08T12:00:24Z https://eprints.nottingham.ac.uk/50508/ Limits, stability and disturbance rejection analysis of voltage control loop strategies for grid forming converters in DC and AC microgrids with high penetration of constant power loads Navarro-Rodríguez, Ángel Garcia, Pablo Cano, J.M. Sumner, M. This paper extensively analyzes the operation limits, system stability and disturbance rejection capability of the voltage control loops used in master-slave AC and DC Microgrids (MGs). Two different control schemes are studied analytically, simulated and experimentally tested, focusing on Constant Power Loads (CPL). Additionally, the use of the virtual capacitance (VC) as a tool for response enhancement is introduced. The study pursues the proper selection of the controllers gains and minimization of capacitance values by considering the dynamic behavior. 2017-09-11 Conference or Workshop Item PeerReviewed application/pdf en https://eprints.nottingham.ac.uk/50508/1/Limits%2C%20Stability%20and%20Disturbance%20Rejection%20Analysis%20of%20Voltage%20Control.pdf Navarro-Rodríguez, Ángel, Garcia, Pablo, Cano, J.M. and Sumner, M. (2017) Limits, stability and disturbance rejection analysis of voltage control loop strategies for grid forming converters in DC and AC microgrids with high penetration of constant power loads. In: 2017 19th European Conference on Power Electronics and Applications (EPE'17 ECCE Europe),, 11-14 September 2017, Warsaw, Poland. Control methods for electrical systems Microgrid Non-linear control Power quality http://ieeexplore.ieee.org/document/8099228/ |
| spellingShingle | Control methods for electrical systems Microgrid Non-linear control Power quality Navarro-Rodríguez, Ángel Garcia, Pablo Cano, J.M. Sumner, M. Limits, stability and disturbance rejection analysis of voltage control loop strategies for grid forming converters in DC and AC microgrids with high penetration of constant power loads |
| title | Limits, stability and disturbance rejection analysis of voltage control loop strategies for grid forming converters in DC and AC microgrids with high penetration of constant power loads |
| title_full | Limits, stability and disturbance rejection analysis of voltage control loop strategies for grid forming converters in DC and AC microgrids with high penetration of constant power loads |
| title_fullStr | Limits, stability and disturbance rejection analysis of voltage control loop strategies for grid forming converters in DC and AC microgrids with high penetration of constant power loads |
| title_full_unstemmed | Limits, stability and disturbance rejection analysis of voltage control loop strategies for grid forming converters in DC and AC microgrids with high penetration of constant power loads |
| title_short | Limits, stability and disturbance rejection analysis of voltage control loop strategies for grid forming converters in DC and AC microgrids with high penetration of constant power loads |
| title_sort | limits, stability and disturbance rejection analysis of voltage control loop strategies for grid forming converters in dc and ac microgrids with high penetration of constant power loads |
| topic | Control methods for electrical systems Microgrid Non-linear control Power quality |
| url | https://eprints.nottingham.ac.uk/50508/ https://eprints.nottingham.ac.uk/50508/ |