Experimental study of the hydrodynamic behaviour of slug flow in a horizontal pipe

This paper investigates the unsteady hydrodynamic behaviour of slug flow occurring within an air–silicone oil mixture, within a horizontal 67 mm internal diameter pipe. A series of slug flow regime experiments were performed for a range of injected air superficial velocities (0.29–1.4 m s−1) and for...

Full description

Bibliographic Details
Main Authors: Abdulkadir, M., Hernandez-Perez, V., Lowndes, I.S., Azzopardi, B.J., Sam-Mbomah, E.
Format: Article
Published: Elsevier 2016
Subjects:
Online Access:https://eprints.nottingham.ac.uk/48437/
_version_ 1848797762489942016
author Abdulkadir, M.
Hernandez-Perez, V.
Lowndes, I.S.
Azzopardi, B.J.
Sam-Mbomah, E.
author_facet Abdulkadir, M.
Hernandez-Perez, V.
Lowndes, I.S.
Azzopardi, B.J.
Sam-Mbomah, E.
author_sort Abdulkadir, M.
building Nottingham Research Data Repository
collection Online Access
description This paper investigates the unsteady hydrodynamic behaviour of slug flow occurring within an air–silicone oil mixture, within a horizontal 67 mm internal diameter pipe. A series of slug flow regime experiments were performed for a range of injected air superficial velocities (0.29–1.4 m s−1) and for liquid flows with superficial velocities of between 0.05–0.47 m s−1. A pair of Electrical Capacitance Tomography (ECT) probes was used to determine: the slug translational velocities of the elongated bubbles and liquid slugs, the slug frequencies, the lengths of elongated bubbles and the liquid slugs, the void fractions within the elongated bubbles and liquid slugs. The pressure drop experienced along the pipe was measured using a differential pressure transducer cell (DP cell). A comparative analysis of the current experimental data and that previously published experimental confirms good agreement.
first_indexed 2025-11-14T20:09:02Z
format Article
id nottingham-48437
institution University of Nottingham Malaysia Campus
institution_category Local University
last_indexed 2025-11-14T20:09:02Z
publishDate 2016
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling nottingham-484372020-05-04T18:25:40Z https://eprints.nottingham.ac.uk/48437/ Experimental study of the hydrodynamic behaviour of slug flow in a horizontal pipe Abdulkadir, M. Hernandez-Perez, V. Lowndes, I.S. Azzopardi, B.J. Sam-Mbomah, E. This paper investigates the unsteady hydrodynamic behaviour of slug flow occurring within an air–silicone oil mixture, within a horizontal 67 mm internal diameter pipe. A series of slug flow regime experiments were performed for a range of injected air superficial velocities (0.29–1.4 m s−1) and for liquid flows with superficial velocities of between 0.05–0.47 m s−1. A pair of Electrical Capacitance Tomography (ECT) probes was used to determine: the slug translational velocities of the elongated bubbles and liquid slugs, the slug frequencies, the lengths of elongated bubbles and the liquid slugs, the void fractions within the elongated bubbles and liquid slugs. The pressure drop experienced along the pipe was measured using a differential pressure transducer cell (DP cell). A comparative analysis of the current experimental data and that previously published experimental confirms good agreement. Elsevier 2016-12-15 Article PeerReviewed Abdulkadir, M., Hernandez-Perez, V., Lowndes, I.S., Azzopardi, B.J. and Sam-Mbomah, E. (2016) Experimental study of the hydrodynamic behaviour of slug flow in a horizontal pipe. Chemical Engineering Science, 156 . pp. 147-161. ISSN 0009-2509 Air–silicone oil ; ECT ; Elongated bubble ; Liquid slug ; Frequency ; Void fraction http://www.sciencedirect.com/science/article/pii/S0009250916304948?via%3Dihub doi:10.1016/j.ces.2016.09.015 doi:10.1016/j.ces.2016.09.015
spellingShingle Air–silicone oil ; ECT ; Elongated bubble ; Liquid slug ; Frequency ; Void fraction
Abdulkadir, M.
Hernandez-Perez, V.
Lowndes, I.S.
Azzopardi, B.J.
Sam-Mbomah, E.
Experimental study of the hydrodynamic behaviour of slug flow in a horizontal pipe
title Experimental study of the hydrodynamic behaviour of slug flow in a horizontal pipe
title_full Experimental study of the hydrodynamic behaviour of slug flow in a horizontal pipe
title_fullStr Experimental study of the hydrodynamic behaviour of slug flow in a horizontal pipe
title_full_unstemmed Experimental study of the hydrodynamic behaviour of slug flow in a horizontal pipe
title_short Experimental study of the hydrodynamic behaviour of slug flow in a horizontal pipe
title_sort experimental study of the hydrodynamic behaviour of slug flow in a horizontal pipe
topic Air–silicone oil ; ECT ; Elongated bubble ; Liquid slug ; Frequency ; Void fraction
url https://eprints.nottingham.ac.uk/48437/
https://eprints.nottingham.ac.uk/48437/
https://eprints.nottingham.ac.uk/48437/