Digital dead-beat and repetitive combined control for stand-alone four-leg VSI
This paper deals with a newly conceived combine control topology. Dead-Beat and Repetitive controllers are proposed to operate jointly in 4-leg VSI for stand-alone applications. In such mode of operation, dedicated controller has to regulate the inverter output voltages, which are measured at the ou...
| Main Authors: | , , , , |
|---|---|
| Format: | Conference or Workshop Item |
| Published: |
2016
|
| Online Access: | https://eprints.nottingham.ac.uk/43814/ |
| _version_ | 1848796774269976576 |
|---|---|
| author | Lidozzi, Alessandro Solero, Luca Crescimbini, Fabio Ji, Chao Zanchetta, Pericle |
| author_facet | Lidozzi, Alessandro Solero, Luca Crescimbini, Fabio Ji, Chao Zanchetta, Pericle |
| author_sort | Lidozzi, Alessandro |
| building | Nottingham Research Data Repository |
| collection | Online Access |
| description | This paper deals with a newly conceived combine control topology. Dead-Beat and Repetitive controllers are proposed to operate jointly in 4-leg VSI for stand-alone applications. In such mode of operation, dedicated controller has to regulate the inverter output voltages, which are measured at the output of the power filter. Each control topology exhibits some specific features. Dead-Beat can rapidly compensate output voltage variations due to load changes; on the contrary, Repetitive Control can provide the required harmonic compensation capabilities that are mandatory to comply with the Standards, when balanced and unbalanced non-linear loads have to be fed. |
| first_indexed | 2025-11-14T19:53:19Z |
| format | Conference or Workshop Item |
| id | nottingham-43814 |
| institution | University of Nottingham Malaysia Campus |
| institution_category | Local University |
| last_indexed | 2025-11-14T19:53:19Z |
| publishDate | 2016 |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | nottingham-438142020-05-04T18:11:51Z https://eprints.nottingham.ac.uk/43814/ Digital dead-beat and repetitive combined control for stand-alone four-leg VSI Lidozzi, Alessandro Solero, Luca Crescimbini, Fabio Ji, Chao Zanchetta, Pericle This paper deals with a newly conceived combine control topology. Dead-Beat and Repetitive controllers are proposed to operate jointly in 4-leg VSI for stand-alone applications. In such mode of operation, dedicated controller has to regulate the inverter output voltages, which are measured at the output of the power filter. Each control topology exhibits some specific features. Dead-Beat can rapidly compensate output voltage variations due to load changes; on the contrary, Repetitive Control can provide the required harmonic compensation capabilities that are mandatory to comply with the Standards, when balanced and unbalanced non-linear loads have to be fed. 2016-09-18 Conference or Workshop Item PeerReviewed Lidozzi, Alessandro, Solero, Luca, Crescimbini, Fabio, Ji, Chao and Zanchetta, Pericle (2016) Digital dead-beat and repetitive combined control for stand-alone four-leg VSI. In: 2016 IEEE Energy Conversion Congress and Exposition (ECCE), 18-22 Sept. 2016, Milwaukee, WI, USA. http://ieeexplore.ieee.org/document/7855045/ |
| spellingShingle | Lidozzi, Alessandro Solero, Luca Crescimbini, Fabio Ji, Chao Zanchetta, Pericle Digital dead-beat and repetitive combined control for stand-alone four-leg VSI |
| title | Digital dead-beat and repetitive combined control for stand-alone four-leg VSI |
| title_full | Digital dead-beat and repetitive combined control for stand-alone four-leg VSI |
| title_fullStr | Digital dead-beat and repetitive combined control for stand-alone four-leg VSI |
| title_full_unstemmed | Digital dead-beat and repetitive combined control for stand-alone four-leg VSI |
| title_short | Digital dead-beat and repetitive combined control for stand-alone four-leg VSI |
| title_sort | digital dead-beat and repetitive combined control for stand-alone four-leg vsi |
| url | https://eprints.nottingham.ac.uk/43814/ https://eprints.nottingham.ac.uk/43814/ |