Numerical investigation into a double skin façade system integrated with shading devices, with reference to the city of Amman, Jordan

ABSTRACT: The aim of this research was to investigate the thermal performance of Double skin facades (DSFs) for office buildings in Amman. Special attention was given to the role of cavity-integrated shading slats. The study was conducted through a parametric study concerning configuration and de...

Full description

Bibliographic Details
Main Author: Amaireh, Ikrima Abd El-Karim Mohammad
Format: Thesis (University of Nottingham only)
Language:English
Published: 2017
Subjects:
Online Access:https://eprints.nottingham.ac.uk/43290/
_version_ 1848796655884697600
author Amaireh, Ikrima Abd El-Karim Mohammad
author_facet Amaireh, Ikrima Abd El-Karim Mohammad
author_sort Amaireh, Ikrima Abd El-Karim Mohammad
building Nottingham Research Data Repository
collection Online Access
description ABSTRACT: The aim of this research was to investigate the thermal performance of Double skin facades (DSFs) for office buildings in Amman. Special attention was given to the role of cavity-integrated shading slats. The study was conducted through a parametric study concerning configuration and design parameters of both DSF’s cavity and shading slats, in addition to boundary conditions. For the purpose of this study, a CFD-Fluent model was developed and validated. Besides, a new method for more accurate representation of solar radiation (as boundary conditions) was developed. Both RNG k-ε and SST k-ω turbulence models were used. The Discrete ordinates (DO) radiation model with non-gray option was selected for modelling of radiation heat transfer. Simulations confirmed that both the width of the cavity and the size and arrangement of openings would have a significant impact on overall performance of the system. The aspect ratio (H/W) of the cavity would further impact its operation, which could contribute to 77% and 26% increase in ventilation and temperature for inner glass surfaces, respectively, of a simple cavity. In addition, among other design parameters, the size and surface emissivity of integrated slats would have the largest influence on the natural ventilation rate in the cavity. The inner glass surface temperature is mainly influenced by the inclination angle and position of these slats in addition to the internal and external environmental conditions. The influence of these slats is also dependent on the aspect ratio of the cavity. Detailed design of these slats would play a further role, together with the boundary conditions (incidence angle) and other design parameters of the cavity (H/W aspect ratio). In Amman, DSFs were shown to have a good performance during heating seasons, as they would enable indoor thermal comfort and ventilation requirements to be met by passive means. During cooling seasons, DSFs with integrated slats would also be able to reduce total solar heat gains if sufficient ventilation could be provided for its cavity. However, artificial cooling is still required for such a hot climate. Controlling the cavity openings is highly recommended for both scenarios. It is recommended that the cavity width is at least 0.6m, the glass transmittance is about 0.8, the size for integrated slat is 20% of the cavity width, and the optimum surface emissivity of the slats is about 0.2. Slats should preferably be placed at mid of cavity or be adjustably according to the seasonal requirements. Optimum inclination angles for slats were found to be 45° degrees and 30° degrees for summer and winter, respectively. General recommendations and design guidelines were provided.
first_indexed 2025-11-14T19:51:26Z
format Thesis (University of Nottingham only)
id nottingham-43290
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T19:51:26Z
publishDate 2017
recordtype eprints
repository_type Digital Repository
spelling nottingham-432902025-02-28T11:56:58Z https://eprints.nottingham.ac.uk/43290/ Numerical investigation into a double skin façade system integrated with shading devices, with reference to the city of Amman, Jordan Amaireh, Ikrima Abd El-Karim Mohammad ABSTRACT: The aim of this research was to investigate the thermal performance of Double skin facades (DSFs) for office buildings in Amman. Special attention was given to the role of cavity-integrated shading slats. The study was conducted through a parametric study concerning configuration and design parameters of both DSF’s cavity and shading slats, in addition to boundary conditions. For the purpose of this study, a CFD-Fluent model was developed and validated. Besides, a new method for more accurate representation of solar radiation (as boundary conditions) was developed. Both RNG k-ε and SST k-ω turbulence models were used. The Discrete ordinates (DO) radiation model with non-gray option was selected for modelling of radiation heat transfer. Simulations confirmed that both the width of the cavity and the size and arrangement of openings would have a significant impact on overall performance of the system. The aspect ratio (H/W) of the cavity would further impact its operation, which could contribute to 77% and 26% increase in ventilation and temperature for inner glass surfaces, respectively, of a simple cavity. In addition, among other design parameters, the size and surface emissivity of integrated slats would have the largest influence on the natural ventilation rate in the cavity. The inner glass surface temperature is mainly influenced by the inclination angle and position of these slats in addition to the internal and external environmental conditions. The influence of these slats is also dependent on the aspect ratio of the cavity. Detailed design of these slats would play a further role, together with the boundary conditions (incidence angle) and other design parameters of the cavity (H/W aspect ratio). In Amman, DSFs were shown to have a good performance during heating seasons, as they would enable indoor thermal comfort and ventilation requirements to be met by passive means. During cooling seasons, DSFs with integrated slats would also be able to reduce total solar heat gains if sufficient ventilation could be provided for its cavity. However, artificial cooling is still required for such a hot climate. Controlling the cavity openings is highly recommended for both scenarios. It is recommended that the cavity width is at least 0.6m, the glass transmittance is about 0.8, the size for integrated slat is 20% of the cavity width, and the optimum surface emissivity of the slats is about 0.2. Slats should preferably be placed at mid of cavity or be adjustably according to the seasonal requirements. Optimum inclination angles for slats were found to be 45° degrees and 30° degrees for summer and winter, respectively. General recommendations and design guidelines were provided. 2017-07-13 Thesis (University of Nottingham only) NonPeerReviewed application/pdf en arr https://eprints.nottingham.ac.uk/43290/1/Ikrima%20Amaireh_PhD%20Thesis%202017.pdf Amaireh, Ikrima Abd El-Karim Mohammad (2017) Numerical investigation into a double skin façade system integrated with shading devices, with reference to the city of Amman, Jordan. PhD thesis, University of Nottingham. DSF CFD Simulation Energy efficiency Natural ventilation Thermal performance Comfort Hot humid Amman Jordan
spellingShingle DSF
CFD
Simulation
Energy efficiency
Natural ventilation
Thermal performance
Comfort
Hot humid
Amman
Jordan
Amaireh, Ikrima Abd El-Karim Mohammad
Numerical investigation into a double skin façade system integrated with shading devices, with reference to the city of Amman, Jordan
title Numerical investigation into a double skin façade system integrated with shading devices, with reference to the city of Amman, Jordan
title_full Numerical investigation into a double skin façade system integrated with shading devices, with reference to the city of Amman, Jordan
title_fullStr Numerical investigation into a double skin façade system integrated with shading devices, with reference to the city of Amman, Jordan
title_full_unstemmed Numerical investigation into a double skin façade system integrated with shading devices, with reference to the city of Amman, Jordan
title_short Numerical investigation into a double skin façade system integrated with shading devices, with reference to the city of Amman, Jordan
title_sort numerical investigation into a double skin façade system integrated with shading devices, with reference to the city of amman, jordan
topic DSF
CFD
Simulation
Energy efficiency
Natural ventilation
Thermal performance
Comfort
Hot humid
Amman
Jordan
url https://eprints.nottingham.ac.uk/43290/