Real-time measurement of the intracellular pH of yeast cells during glucose metabolism using ratiometric fluorescent nanosensors

Intracellular pH is a key parameter that influences many biochemical and metabolic pathways that can also be used as an indirect marker to monitor metabolic and intracellular processes. Herein, we utilise ratiometric fluorescent pH-sensitive nanosensors with an extended dynamic pH range to measure t...

Full description

Bibliographic Details
Main Authors: Elsutohy, Mohamed M., Chauhan, Veeren M., Markus, Robert, Kyyaly, Mohammed Aref, Tendler, Saul J.B., Aylott, Jonathan W.
Format: Article
Published: Royal Society of Chemistry 2017
Online Access:https://eprints.nottingham.ac.uk/42744/
_version_ 1848796557616349184
author Elsutohy, Mohamed M.
Chauhan, Veeren M.
Markus, Robert
Kyyaly, Mohammed Aref
Tendler, Saul J.B.
Aylott, Jonathan W.
author_facet Elsutohy, Mohamed M.
Chauhan, Veeren M.
Markus, Robert
Kyyaly, Mohammed Aref
Tendler, Saul J.B.
Aylott, Jonathan W.
author_sort Elsutohy, Mohamed M.
building Nottingham Research Data Repository
collection Online Access
description Intracellular pH is a key parameter that influences many biochemical and metabolic pathways that can also be used as an indirect marker to monitor metabolic and intracellular processes. Herein, we utilise ratiometric fluorescent pH-sensitive nanosensors with an extended dynamic pH range to measure the intracellular pH of yeast (Saccharomyces cerevisiae) during glucose metabolism in real-time. Ratiometric fluorescent pH-sensitive nanosensors consisting of a polyacrylamide nanoparticle matrix covalently linked to two pH-sensitive fluorophores, Oregon green (OG) and 5(6)carboxyfluorescein (FAM), and a reference pH-insensitive fluorophore, 5(6)carboxytetramethylrhodamine (TAMRA), were synthesised. Nanosensors were functionalised with acrylamidopropyltrimethyl ammonium hydrochloride (ACTA) to confer a positive charge to the nanoparticle surfaces that facilitated nanosensor delivery to yeast cells, negating the need to use stress inducing techniques. The results showed that under glucose-starved conditions the intracellular pH of yeast population (n ≈ 200) was 4.67 ± 0.15. Upon addition of D-(+)-glucose (10 mM), this pH value decreased to pH 3.86 ± 0.13 over a period of 10 minutes followed by a gradual rise to a maximal pH of 5.21 ± 0.26, 25 minutes after glucose addition. 45 minutes after the addition of glucose, the intracellular pH of yeast cells returned to that of the glucose starved conditions. This study advances our understanding of the interplay between glucose metabolism and pH regulation in yeast cells, and indicates that the intracellular pH homestasis in yeast is highly regulated and demonstrates the utility of nanosensors for real-time intracellular pH measurements.
first_indexed 2025-11-14T19:49:53Z
format Article
id nottingham-42744
institution University of Nottingham Malaysia Campus
institution_category Local University
last_indexed 2025-11-14T19:49:53Z
publishDate 2017
publisher Royal Society of Chemistry
recordtype eprints
repository_type Digital Repository
spelling nottingham-427442020-05-04T18:45:36Z https://eprints.nottingham.ac.uk/42744/ Real-time measurement of the intracellular pH of yeast cells during glucose metabolism using ratiometric fluorescent nanosensors Elsutohy, Mohamed M. Chauhan, Veeren M. Markus, Robert Kyyaly, Mohammed Aref Tendler, Saul J.B. Aylott, Jonathan W. Intracellular pH is a key parameter that influences many biochemical and metabolic pathways that can also be used as an indirect marker to monitor metabolic and intracellular processes. Herein, we utilise ratiometric fluorescent pH-sensitive nanosensors with an extended dynamic pH range to measure the intracellular pH of yeast (Saccharomyces cerevisiae) during glucose metabolism in real-time. Ratiometric fluorescent pH-sensitive nanosensors consisting of a polyacrylamide nanoparticle matrix covalently linked to two pH-sensitive fluorophores, Oregon green (OG) and 5(6)carboxyfluorescein (FAM), and a reference pH-insensitive fluorophore, 5(6)carboxytetramethylrhodamine (TAMRA), were synthesised. Nanosensors were functionalised with acrylamidopropyltrimethyl ammonium hydrochloride (ACTA) to confer a positive charge to the nanoparticle surfaces that facilitated nanosensor delivery to yeast cells, negating the need to use stress inducing techniques. The results showed that under glucose-starved conditions the intracellular pH of yeast population (n ≈ 200) was 4.67 ± 0.15. Upon addition of D-(+)-glucose (10 mM), this pH value decreased to pH 3.86 ± 0.13 over a period of 10 minutes followed by a gradual rise to a maximal pH of 5.21 ± 0.26, 25 minutes after glucose addition. 45 minutes after the addition of glucose, the intracellular pH of yeast cells returned to that of the glucose starved conditions. This study advances our understanding of the interplay between glucose metabolism and pH regulation in yeast cells, and indicates that the intracellular pH homestasis in yeast is highly regulated and demonstrates the utility of nanosensors for real-time intracellular pH measurements. Royal Society of Chemistry 2017-05-14 Article PeerReviewed Elsutohy, Mohamed M., Chauhan, Veeren M., Markus, Robert, Kyyaly, Mohammed Aref, Tendler, Saul J.B. and Aylott, Jonathan W. (2017) Real-time measurement of the intracellular pH of yeast cells during glucose metabolism using ratiometric fluorescent nanosensors. Nanoscale, 9 (18). pp. 5904-5911. ISSN 2040-3372 http://pubs.rsc.org/en/Content/ArticleLanding/2017/NR/C7NR00906B#!divAbstract doi:10.1039/c7nr00906b doi:10.1039/c7nr00906b
spellingShingle Elsutohy, Mohamed M.
Chauhan, Veeren M.
Markus, Robert
Kyyaly, Mohammed Aref
Tendler, Saul J.B.
Aylott, Jonathan W.
Real-time measurement of the intracellular pH of yeast cells during glucose metabolism using ratiometric fluorescent nanosensors
title Real-time measurement of the intracellular pH of yeast cells during glucose metabolism using ratiometric fluorescent nanosensors
title_full Real-time measurement of the intracellular pH of yeast cells during glucose metabolism using ratiometric fluorescent nanosensors
title_fullStr Real-time measurement of the intracellular pH of yeast cells during glucose metabolism using ratiometric fluorescent nanosensors
title_full_unstemmed Real-time measurement of the intracellular pH of yeast cells during glucose metabolism using ratiometric fluorescent nanosensors
title_short Real-time measurement of the intracellular pH of yeast cells during glucose metabolism using ratiometric fluorescent nanosensors
title_sort real-time measurement of the intracellular ph of yeast cells during glucose metabolism using ratiometric fluorescent nanosensors
url https://eprints.nottingham.ac.uk/42744/
https://eprints.nottingham.ac.uk/42744/
https://eprints.nottingham.ac.uk/42744/