The impact of electrode resistance on the biogalvanic characterisation technique

Measurement of a tissue-specific electrical resistance may offer a discriminatory metric for evaluation of tissue health during cancer surgery. With a move toward minimally-invasive procedures, applicable contact sensing modalities must be scalable, fast and robust. A passive resistance characterisa...

Full description

Bibliographic Details
Main Authors: Chandler, J.H., Head, D.A., Hubbard, Matthew E., Neville, A., Jayne, D.G., Culmer, P.R.
Format: Article
Published: IOP Publishing 2016
Online Access:https://eprints.nottingham.ac.uk/40826/
_version_ 1848796141821362176
author Chandler, J.H.
Head, D.A.
Hubbard, Matthew E.
Neville, A.
Jayne, D.G.
Culmer, P.R.
author_facet Chandler, J.H.
Head, D.A.
Hubbard, Matthew E.
Neville, A.
Jayne, D.G.
Culmer, P.R.
author_sort Chandler, J.H.
building Nottingham Research Data Repository
collection Online Access
description Measurement of a tissue-specific electrical resistance may offer a discriminatory metric for evaluation of tissue health during cancer surgery. With a move toward minimally-invasive procedures, applicable contact sensing modalities must be scalable, fast and robust. A passive resistance characterisation method utilising a biogalvanic cell as an intrinsic power source has been proposed as a potentially suitable solution. Previous work has evaluated this system with results showing effective discrimination of tissue type and damage (through electroporation). However, aspects of the biogalvanic cell have been found to influence the characterisation performance, and are not currently accounted for within the system model. In particular, the electrode and salt-bridge resistance are not independently determined, leading to over-predictions of tissue resistivity. This paper describes a more comprehensive model and characterisation scheme, with electrode parameters and salt-bridge resistivity being evaluated independently. In a generalised form, the presented model illustrates how the relative resistive contributions from the electrodes and medium relate to the existing characterisation method efficacy. We also describe experiments with physiologically relevant salt solutions (1.71, 17.1, 154 mM), used for validation and comparison. The presented model shows improved performance over the current biogalvanic measurement technique at the median conductivity. Both the proposed and extant system models become unable to predict conductivity accurately at high conductivity due to the dominance of the electrodes. The characterisation techniques have also been applied to data collected on freshly excised human colon tissue (healthy and cancerous). The findings suggest that the resistance of the cell under the test conditions is electrode dominated, leading to erroneous tissue resistance determination. Measurement optimisation strategies and the surgical applicability of the biogalvanic technique are discussed in light of these findings.
first_indexed 2025-11-14T19:43:16Z
format Article
id nottingham-40826
institution University of Nottingham Malaysia Campus
institution_category Local University
last_indexed 2025-11-14T19:43:16Z
publishDate 2016
publisher IOP Publishing
recordtype eprints
repository_type Digital Repository
spelling nottingham-408262020-05-04T18:24:32Z https://eprints.nottingham.ac.uk/40826/ The impact of electrode resistance on the biogalvanic characterisation technique Chandler, J.H. Head, D.A. Hubbard, Matthew E. Neville, A. Jayne, D.G. Culmer, P.R. Measurement of a tissue-specific electrical resistance may offer a discriminatory metric for evaluation of tissue health during cancer surgery. With a move toward minimally-invasive procedures, applicable contact sensing modalities must be scalable, fast and robust. A passive resistance characterisation method utilising a biogalvanic cell as an intrinsic power source has been proposed as a potentially suitable solution. Previous work has evaluated this system with results showing effective discrimination of tissue type and damage (through electroporation). However, aspects of the biogalvanic cell have been found to influence the characterisation performance, and are not currently accounted for within the system model. In particular, the electrode and salt-bridge resistance are not independently determined, leading to over-predictions of tissue resistivity. This paper describes a more comprehensive model and characterisation scheme, with electrode parameters and salt-bridge resistivity being evaluated independently. In a generalised form, the presented model illustrates how the relative resistive contributions from the electrodes and medium relate to the existing characterisation method efficacy. We also describe experiments with physiologically relevant salt solutions (1.71, 17.1, 154 mM), used for validation and comparison. The presented model shows improved performance over the current biogalvanic measurement technique at the median conductivity. Both the proposed and extant system models become unable to predict conductivity accurately at high conductivity due to the dominance of the electrodes. The characterisation techniques have also been applied to data collected on freshly excised human colon tissue (healthy and cancerous). The findings suggest that the resistance of the cell under the test conditions is electrode dominated, leading to erroneous tissue resistance determination. Measurement optimisation strategies and the surgical applicability of the biogalvanic technique are discussed in light of these findings. IOP Publishing 2016-12-23 Article PeerReviewed Chandler, J.H., Head, D.A., Hubbard, Matthew E., Neville, A., Jayne, D.G. and Culmer, P.R. (2016) The impact of electrode resistance on the biogalvanic characterisation technique. Physiological Measurement, 38 (2). pp. 101-115. ISSN 1361-6579 http://iopscience.iop.org/article/10.1088/1361-6579/38/2/101/meta doi:10.1088/1361-6579/38/2/101 doi:10.1088/1361-6579/38/2/101
spellingShingle Chandler, J.H.
Head, D.A.
Hubbard, Matthew E.
Neville, A.
Jayne, D.G.
Culmer, P.R.
The impact of electrode resistance on the biogalvanic characterisation technique
title The impact of electrode resistance on the biogalvanic characterisation technique
title_full The impact of electrode resistance on the biogalvanic characterisation technique
title_fullStr The impact of electrode resistance on the biogalvanic characterisation technique
title_full_unstemmed The impact of electrode resistance on the biogalvanic characterisation technique
title_short The impact of electrode resistance on the biogalvanic characterisation technique
title_sort impact of electrode resistance on the biogalvanic characterisation technique
url https://eprints.nottingham.ac.uk/40826/
https://eprints.nottingham.ac.uk/40826/
https://eprints.nottingham.ac.uk/40826/